All Title Author
Keywords Abstract

Publish in OALib Journal
ISSN: 2333-9721
APC: Only $99

ViewsDownloads

Relative Articles

Analysis of Residual Solvents in Annatto Extracts Using a Static Headspace Gas Chromatography Method

Development and validation of a headspace gas chromatographic method for the determination of residual solvents in arterolane (RBx11160) maleate bulk drug

Development and Validation for Reverse Phase High Performance Liquid Chromatographic Method for Simultaneously Determination for Diphenoxylic Acid, Nitrileamide and Bromdiphenyl Butoro Nitrile in Diphenoxylate Hydrochloride Bulk Drug

PREPARATION AND EVALUATION OF TRAMADOL HYDROCHLORIDE MICROSPHERES BY COACERVATION PHASE SEPARATION TECHNIQUE USING VARIOUS SOLVENTS AND NON-SOLVENTS

Efficacies of Regulatory Policies to Control Massive Use of Diphenoxylate

Validated HPTLC method for simultaneous determination of quinapril hydrochloride and hydrochlorothiazide in a tablet dosage form

Determination of dichloromethane and trichloromethane residues in ranitidine hydrochloride by headspace liquid phase microextraction coupled with gas chromatography
顶空液相微萃取-气相色谱法测定盐酸雷尼替丁中二氯甲烷和三氯甲烷的残留量

Determination of Residual Acetone in Soybean Phospholipids by Headspace Gas Chromatography
顶空气相色谱法测定粉状大豆磷脂中的丙酮残留量

SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS ESTIMATION OF AMBROXOL HYDROCHLORIDE, LEVOCETIRIZINE DIHYDROCHLORIDE AND PHENYLEPHRINE HYDROCHLORIDE IN TABLET DOSAGE FORM

顶空气相色谱法测定氯苯达诺原料药中的残留溶剂含量
Determination of Residual Solvent in Clofedanol by Gas Chromatography with Headspace Sampling

More...

Development and Validation of Headspace Method for Determination of Residual Solvents in Diphenoxylate Hydrochloride Bulk Drug

DOI: 10.5923/j.chemistry.20120202.01

Keywords: Diphenoxylate Hydrochloride, Headspace GC, Residual Solvent, Quantification, Impurity Profiling

Full-Text   Cite this paper   Add to My Lib

Abstract:

Organic volatile impurities by Headspace GC method was developed and validated for Diphenoxylate hydrochloride bulk drug for its seven residual solvents. Analysis was performed on Perkin Elmer HS 40 system with auto injector. Carrier gas Helium was used with constant flow rate of 2.5mL/min as carrier gas and the separation of residual solvents were achieved on DB-5 column. The thermostat temperature was 125 °C for 20 minute for each vial and after the equilibration the vials were pressurized and injected on GC column. FID detector was used for detection. The parameter for which the method was validated included specificity, limit of detection and quantification, linearity, precision, accuracy and robustness. The method was successfully used to quantify the levels of specified limit for residual solvents in Diphenoxylate hydrochloride bulk drug.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

微信:OALib Journal