全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

New approach for the glaucoma detection with pupil perimetry

DOI: http://dx.doi.org/10.2147/OPTH.S9936

Keywords: pupil perimetry, percentage pupil constriction, glaucoma, pattern deviation, gray scale

Full-Text   Cite this paper   Add to My Lib

Abstract:

pproach for the glaucoma detection with pupil perimetry Original Research (4026) Total Article Views Authors: Ken Asakawa, Nobuyuki Shoji, Hitoshi Ishikawa, et al Published Date June 2010 Volume 2010:4 Pages 617 - 623 DOI: http://dx.doi.org/10.2147/OPTH.S9936 Ken Asakawa1, Nobuyuki Shoji1,2, Hitoshi Ishikawa1,2, Kimiya Shimizu3 1Department of Ophthalmology and Visual Science, Kitasato University Graduate School, Doctors Program of Medical Science, 2Department of Orthoptics and Visual Science, Kitasato University, School of Allied Health Science, 3Department of Ophthalmology, Kitasato University, School of Medicine Objective: To calculate the pattern deviation for identifying abnormal points of pupil perimetry, and also to evaluate the grayscale display for distinguishing glaucomatous pupil field loss (abnormal test points) from normal pupil field (normal test points). Methods: Fourteen patients ranging in age from 51 to 80 years, who had normal-tension glaucoma (6 eyes) and primary open-angle glaucoma (8 eyes) were tested. Pupil perimetry (Kowa & Hamamatsu, Japan) was used to objectively measure the visual field. Also, to obtain a subjective visual field, the analysis was performed with a Humphrey Field Analyzer (30-2, Full threshold program, Carl Zeiss Meditec, Dublin). Of the 76 test points, the 22 surrounding points and the 3 points corresponding to the blind spot are excluded; and among the remaining 51 points, the 85th percentile value of pupil perimetry was calculated. The abnormal and normal test points were recorded, and the amount of positive or negative deviation of each test point from the normal median value for the corresponding test points was determined. We also used this technique to identify the value for distinguishing glaucomatous pupil field loss from the normal pupil field. Results: This study could be improved by calculating the sensitivity and specificity of a certain cut-off value between the normative data and the glaucoma patients. The value for identifying both abnormal and normal test points was a negative deviation of –4. Based on these results, pupil perimetry gray scales were determined: white (< –3), 25% gray (from –4 to –8), 50% gray (from –9 to –13), 75% gray (from –14 to –18) and black (> –19). Glaucomatous pupil field losses were generally distinguished from the normal pupil field by use of a gray scale. Conclusion: Our studies demonstrated that, when a deviation of > –4 was regarded as an abnormal value, the detection of pupil perimetry exhibited improvement in glaucoma patients.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133