Delayed Lumbar Artery Laceration and Symptomatic Retroperitoneal Hemorrhage Following IVC Filter Placement

DOI: 10.4236/ojrad.2015.54029, PP. 212-216

Keywords: Inferior Vena Cava Filter, Pulmonary Embolism, Hemorrhage, Arterial Embolization, Lumbar Artery Laceration

Full-Text   Cite this paper   Add to My Lib

Abstract:

Inferior vena cava filters are placed in selected patients to protect against potentially fatal pulmonary embolism. Generally, filter placement is regarded as a safe procedure although rare complications may arise. Recurrent thromboembolic events are the most common complications assoiated with inferior vena cava filters; however, there are multiple reports of filter fracture, migration, embolization, penetration and perforation. The aim of this report is to illustrate a serious potential complication of inferior vena cava filters. We report a rare case of symptomatic retroperitoneal hemorrhage occurring 3 weeks after filter placement treated successfully with selective arterial embolization of a lumbar artery laceration. This case serves to highlight the importance of retrieving filters when they are no longer beneficial.

References

[1]  Keeling, A.N., Kinney, T.B. and Lee, M.J. (2008) Optional Inferior Vena Caval Filters: Where Are We Now? European Radiology, 18, 1556-1568.
http://dx.doi.org/10.1007/s00330-008-0923-z
[2]  Angel, L.F., Tapson, V., Galgon, R.E., Restrepo, M.I. and Kaufman, J. (2011) Systematic Review of the Use of Retrievable Inferior Vena Cava Filters. Journal of Vascular and Interventional Radiology, 22, 1522-1530.
http://dx.doi.org/10.1016/j.jvir.2011.08.024
[3]  Andreoli, J.M., Lewandowski, R.J., Vogelzang, R.L. and Ryu, R.K. (2014) Comparison of Complication Rates Associated with Permanent and Retrievable Inferior Vena Cava Filters: A Review of the MAUDE Database. Journal of Vascular and Interventional Radiology, 25, 1181-1185.
http://dx.doi.org/10.1016/j.jvir.2014.04.016
[4]  Wang, W., Spain, J. and Tam, M.D. (2011) Acute Abdominal Pain after Retrievable Inferior Vena Cava filter Insertion: Case Report of Caval Perforation by an Option Filter. Cardio Vascular and Interventional Radiology, 34, 883-885.
http://dx.doi.org/10.1007/s00270-010-0080-z
[5]  Satya, R., Anderson, J., Lievano, G. and Satya, R.J. (2009) Inferior Vena Cava (IVC) Rupture and Retroperitoneal Hemorrhage Caused by IVC Filter Migration. Journal of Vascular and Interventional Radiology, 20, 1102-1104.
http://dx.doi.org/10.1016/j.jvir.2009.05.001
[6]  Brown, A.P., Miller, M.J. and Smith, T.P. (2007) Caval Penetration with Retroperitoneal Hemorrhage Following Placement of an Inferior Vena Cava (IVC) Filter. Seminars in Interventional Radiology, 24, 312-315.
http://dx.doi.org/10.1055/s-2007-985741
[7]  Woodward, E.B., Farber, A., Wagner, W.H., et al. (2002) Delayed Retroperitoneal Arterial Hemorrhage after Inferior Vena Cava (IVC) Filter Insertion: Case Report and Literature Review of Caval Perforations by IVC Filters. Annals of Vascular Surgery, 16, 193-196.
http://dx.doi.org/10.1007/s10016-001-0150-4
[8]  Dillon, B.J. and Alomari, A.I. (2008) Lumbar Artery Pseudoaneurysm Following Inferior Vena Cava Filter Placement. Journal of Vascular and Interventional Radiology, 19, 1673-1674.
http://dx.doi.org/10.1016/j.jvir.2008.08.003
[9]  Skeik, N., McEachen, J.C., Stockland, A.H., et al. (2011) Lumbar Artery Pseudoaneurysm Caused by a Gunther Tulip Inferior Vena Cava Filter. Vascular and Endovascular Surgery, 45, 756-760.
http://dx.doi.org/10.1177/1538574411419373
[10]  Tsekouras, N., Whalen, R.C. and Comerota, A.J. (2015) Lumbar Artery Pseudoaneurysm in a Patient with Inferior Vena Cava Filter and History of Strenuous Physical Exercise. Journal of Vascular Surgery, 61, 796-799.
http://dx.doi.org/10.1016/j.jvs.2013.09.057
[11]  U. S. Food and Drug Administration (2014) Removing Retrievable Inferior Vena Cava Filters: FDA Safety Communication. U. S. Food and Drug Administration.
[12]  Morales, J.P., Li, X., Irony, T.Z., Ibrahim, N.G., Moynahan, M. and Cavanaugh Jr., K.J. (2013) Decision Analysis of Retrievable Inferior Vena Cava Filters in Patients without Pulmonary Embolism. Journal of Vascular Surgery: Venous and Lymphatic Disorders, 1, 376-384.
http://dx.doi.org/10.1016/j.jvsv.2013.04.005
[13]  Zhou, D., Moon, E., Bullen, J., Sands, M., Levitin, A. and Wang, W. (2014) Penetration of Celect Inferior Vena Cava Filters: Retrospective Review of CT Scans in 265 Patients. American Journal of Roentgenology, 202, 643-647.
http://dx.doi.org/10.2214/AJR.13.11097
[14]  Zhou, D., Spain, J., Moon, E., McLennan, G., Sands, M.J. and, Wang, W. (2012) Retrospective Review of 120 Celect Inferior Vena Cava Filter Retrievals: Experience at a Single Institution. Journal of Vascular and Interventional Radiology, 23, 1557-1563.
http://dx.doi.org/10.1016/j.jvir.2012.08.016
[15]  Durack, J.C., Westphalen, A.C., Kekulawela, S., et al. (2012) Perforation of the IVC: Rule Rather than Exception after Longer Indwelling Times for the Gunther Tulip and Celect Retrievable Filters. CardioVascular and Interventional Radiology, 35, 299-308.
http://dx.doi.org/10.1007/s00270-011-0151-9
[16]  Pham, J.D., Huang, S.Y., Sabir, S.H., Huynh, T. and, Wallace, M.J. (2014) Celect Filter Penetration of Aorta and Lumbar Artery. Journal of Vascular and Interventional Radiology, 25, 487-490.
[17]  Bos, A., Van Ha, T., van Beek, D., et al. (2015) Strut Penetration: Local Complications, Breakthrough Pulmonary Embolism, and Retrieval Failure in Patients with Celect Vena Cava Filters. Journal of Vascular and Interventional Radiology, 26, 101-106.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133