Infants spend most of their indoor time at home; however, residential air quality is poorly understood. We investigated the air quality of infants’ homes in the New England area of the U.S. Participants ( N = 53) were parents of infants (0–6 months) who completed telephone surveys to identify potential pollutant sources in their residence. Carbon monoxide (CO), carbon dioxide (CO 2), particulate matter with aerodynamic diameter ≤0.5 μm (PM 0.5), and total volatile organic compounds (TVOCs) were measured in 10 homes over 4–7 days, and levels were compared with health-based guidelines. Pollutant levels varied substantially across homes and within homes with overall levels for some homes up to 20 times higher than for other homes. Average levels were 0.85 ppm, 663.2 ppm, 18.7 μg/m 3, and 1626 μg/m 3 for CO, CO 2, PM 0.5, and TVOCs, respectively. CO 2, TVOCs, and PM 0.5 levels exceeded health-based indoor air quality guidelines. Survey results suggest that nursery renovations and related potential pollutant sources may be associated with differences in urbanicity, income, and presence of older children with respiratory ailments, which could potentially confound health studies. While there are no standards for indoor residential air quality, our findings suggest that additional research is needed to assess indoor pollution exposure for infants, which may be a vulnerable population.
References
[1]
Ballester, F.; Fuentes-Leonarte, V.; Tenías, J.M. Sources of indoor air pollution and respiratory health in preschool children. J. Environ. Public Health 2009, 2009, 727516:1–727516:19.
[2]
Brown, T.; Holmes, P.; Harrison, P.T.C. Review: The applicability of epidemiological methods to the assessment of the risks to human health of indoor air pollution: An overview. Indoor Built Environ. 2010, 19, 311–326.
[3]
Kaplan, C. Indoor air pollution from unprocessed solid fuels in developing countries. Rev. Environ. Health 2010, 25, 221–242.
[4]
Roberts, J.W.; Dickey, P. Exposure of children to pollutants in house dust and indoor air. Rev. Environ. Contam. Toxicol. 1995, 143, 59–78.
[5]
Zhang, J.; Smith, K.R. Indoor air pollution: A global health concern. Br. Med. Bull. 2003, 68, 209–225.
[6]
Prazad, P.; Cortes, D.R.; Puppala, B.L.; Donovan, R.; Kumar, S.; Gulati, A. Airborne concentrations of volatile organic compounds in neonatal incubators. J. Perinatol. 2008, 28, 534–540.
[7]
United State Environmental Protection Agency (U.S. EPA). The Inside Story: A Guide to Indoor Air Quality; U.S. EPA Office of Air and Radiation, & Consumer Product Safety Commission: Washington, DC, USA, 1995. Report No. 402-K-93-007.
[8]
Weschler, C.J. Chemistry in indoor environments: 20 years of research. Indoor Air 2011, 21, 205–218.
Landrigan, P.J.; Kimmel, C.A.; Correa, A.; Eskenazi, B. Children’s health and the environment: Public health issues and challenges for risk assessment. Environ. Health Perspect. 2004, 112, 257–265.
[11]
Perera, F.P. Children are likely to suffer most from our fossil fuel addiction. Environ. Health Perspect. 2008, 116, 987–990.
[12]
Wang, L.; Pinkerton, K.E. Air pollutant effects on fetal and early postnatal development. Birth Defects Res. Part C, Embryo Today: Rev. 2007, 81, 144–154.
[13]
Trasande, L.; Boscarino, J.; Graber, N.; Falk, R.; Schechter, C.; Galvez, M.; Dunkel, G.; Geslani, J.; Moline, J.; Kaplan-Liss, E.; et al. The environment in pediatric practice: A study of New York pediatricians’ attitudes, beliefs, and practices towards children’s environmental health. J. Urban Health 2006, 83, 760–772.
[14]
Lloyd-Smith, M.; Sheffield-Brotherton, B. Children’s environmental health: Intergenerational equity in action—a civil society perspective. Ann. NY Acad. Sci. 2008, 1140, 190–200.
[15]
Klonoff-Cohen, H.; Lam, P.K.; Lewis, A. Outdoor carbon monoxide, nitrogen dioxide, and sudden infant death syndrome. Arch. Dis. Child. 2005, 90, 750–753.
[16]
Tong, S.; Colditz, P. Air pollution and sudden infant death syndrome: a literature review. Paediatr. Perinat. Epidmiol. 2004, 18, 327–335.
[17]
Jones, J.; Stick, S.; Dingle, P.; Franklin, P. Spatial variability of particulates in homes: Implications for infant exposure. Sci. Total Environ. 2007, 376, 317–323.
[18]
Bateson, T.F.; Schwartz, J. Children’s response to air pollutants. J. Toxicol. Environ. Health, Part A 2008, 71, 238–243.
[19]
Mitchell, B.F.; Tarragt, M.J. Are animal models relevant to key aspects of human parturition? Am. J. Physiol. 2009, 300, R525–R545.
[20]
AirAdivce. Building Advice: Advancing Building Performance, Owner’s Manual; AirAdvice: Portland, OR, USA, 2010.
[21]
AirAdvice. Model 7100 IEQ Monitor Specification & Sensor Descriptions; AirAdvice: Portland, OR, USA, 2010.
[22]
Bell, M.L.; Peng, R.D.; Dominici, F.; Samet, J.M. Emergency hospital admissions for cardiovascular diseases and ambient levels ofcarbon monoxide: Results for 126 United States urban counties, 1999–2005. Circulation 2009, 120, 949–955.
[23]
Dashdendev, B.; Fukushima, L.K.; Woo, M.S.; Ganbaatar, E.; Warburton, D. Carbon monoxidepollution and lung function in urban compared with rural Mongolian children. Respirology 2011, 16, 653–658.
[24]
Pope, C.A., III; Dockery, D.W. Health effects of fine particulate air pollution: Lines that connect. J. Air Waste Manag. Assoc. 2006, 56, 709–742.
[25]
Rumchev, K.; Spickett, J.; Bulsara, M.; Phillips, M.; Stick, S. Association of domestic exposure to volatile organic compounds with asthma in young children. Thorax 2004, 59, 746–751.
[26]
Wolkoff, P. Trends in Europe to reduce the indoor air pollution of VOCs. Indoor Air 2003, 13, 5–11.
[27]
Chew, G.L.; Correa, J.C.; Perzanowski, M.S. Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools. Indoor Air 2005, 15 (Suppl. 6), 228–234.
[28]
Esposito, W.A.; Chew, G.L.; Correa, J.C.; Chillrud, S.N.; Miller, R.L.; Kinney, P.L. Quantitative measurement of airborne cockroach allergen in New York City apartments. Indoor Air 2011, 21, 512–520.
[29]
Moriske, H.J.; Drews, M.; Ebert, G.; Menk, G.; Scheller, C.; Sch?ndube, M.; Konieczny, L. Indoor air pollution by different heating systems: Coal burning, open fireplaceand central heating. Toxicol. Lett. 1996, 88, 349–354.
[30]
Raaschou-Nielsen, O.; S?rensen, M.; Hertel, O.; Chawes, B.L.K.; Vissing, N.; B?nnelykke, K.; Bisgaard, H. Predictors of indoor fine particulate matter in infants’ bedrooms in Denmark. Environ. Res. 2011, 111, 87–93.
[31]
Silva, G.V.; Vasconcelos, M.T.S.D.; Santos, A.M.; Fernandes, E.O. Comparison of the substrate effect on VOC emissions from water based varnish and latex paint. Environ. Sci. Pollut. Res. 2003, 10, 209–216.
[32]
Song, J.E.; Kim, Y.S.; Sohn, J.Y. The impact of plants on the reduction of volatile organic compounds in a small space. J. Physiol. Anthropol. 2007, 26, 599–603.
[33]
United State Environmental Protection Agency (U.S. EPA). Care for Your Air: A Guide to Indoor Air Quality; U.S. EPA: Washington, DC, USA, 2008. EPA402/F-08/008.
[34]
Health Canada. Residential Indoor Air Quality Guidelines: Carbon Monoxide; Health Canada: Ottawa, Canada, 2010. Cat.: H128-1/10-603E.
[35]
Occupational Safety and Health Administration (OSHA). Occupational Safety and Health Standards, Toxic and Hazardous Substances; OSHA: Washington, DC, USA, 1999. 29 CFR Table Z-1.
[36]
National Institute for Occupational Safety and Health (NIOSH). Recommendations for Occupational Safety and Health: Compendium of Policy Documents and Statements; U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control, NIOSH: Cincinnati, OH, USA, 1992. DHHS (NIOSH) Publication No. 92-100.
[37]
American Conference of Governmental Industrial Hygienists (ACGIH). Threshold Limit Values for Chemical Substances and Physicalagents and Biological Exposure Indices for 1994-1995. ACGIH: Cincinnati, OH, USA, 1994.
[38]
United State Environmental Protection Agency (U.S. EPA). Air Quality Criteria for Carbon Monoxide; U.S. EPA Office of Research and Development: Washington, DC, USA, 2000. EPA 600/P-99/001F.
[39]
World Health Organization (WHO). Air Quality Guidelines for Europe; WHO Regional Publications, European Series, No. 91; WHO: Copenhagen, Denmark, 2000.
[40]
American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE). Ventilation for Acceptable Indoor Air Quality; ASHRAE: Atlanta, GA, USA, 1989. ANSI/ASHRAE 62-1989.
[41]
American Conference of Governmental Industrial Hygienists (ACGIH). The Threshold Limit Values (TLVs) and Biological Exposure Indices (BEIs); ACGIH: Cincinnati, OH, USA, 1999.
[42]
Peel, J.L.; Kelin, M.; Flanders, W.D.; Mulholland, J.A.; Freed, G.; Tolbert, P.E. Ambient air pollution and apnea and bradycardia in high-risk infants on home monitors. Environ. Health Perspect. 2011, 119, 1321–1327.
[43]
Kaiser, R.; Romieu, I.; Medina, S.; Schwartz, J.; Krzyzanowski, M.; Kunzli, N. Air pollution attributable postneonatal infant mortality in U.S. metropolitan areas: A risk assessment study. Environ. Health 2004, 3.
[44]
Son, J.Y.; Bell, M.L.; Lee, J.T. Survival analysis of long-term exposure to different sizes of airborne particulate matter and risk of infant mortality using a birth cohort in Seoul, Korea. Environ. Health Perspect. 2011, 119, 725–730.
[45]
Woodruff, T.J.; Darrow, L.A.; Parker, J.D. Air pollution and postneonatal infant mortality in the United States, 1999–2002. Environ. Health Perspect. 2008, 116, 110–115.
[46]
Hulin, M.; Caillaud, D.; Annesi-Maesano, I. Indoor air pollution and childhood asthma: Variations between urban and rural areas. Indoor Air 2010, 20, 502–514.
[47]
Hsu, N.Y.; Wang, J.Y.; Su, H.J. A dose-dependent relationship between the severity of visible mold growth and IgE levels of pre-school-aged resident children in Taiwan. Indoor Air 2010, 20, 392–398.
[48]
Wilson, N.K.; Chuang, J.C.; Morgan, M.K.; Lordo, R.A.; Sheldon, L.S. An observational study of the potential exposures of preschool children to pentachlorophenol, bisphenol-A, and nonylphenol at home and daycare. Environ. Res. 2007, 103, 9–20.
[49]
Laquatra, J.; Maxwell, L.E.; Pierce, M. Indoor air pollutants: Limited-resource households and child care facilities. J. Environ. Health 2005, 67, 39–43.
[50]
Ferng, S.F.; Lee, L.W. Indoor air quality assessment of daycare facilities with carbon dioxide, temperature, and humidity as indicators. J. Environ. Health 2002, 63, 14–18.
[51]
Karthikeyan, S.; Perumal, S.V.; Balasubramanian, R.; Zuraimi, M.S.; Tham, K.W. Determination of ozone in outdoor and indoor environments using nitrate-impregnated passive samplers followed by ion chromatography. J. Air Waste Manage. Assoc. 2007, 57, 974–980.
[52]
Tielsch, J.M.; Katz, J.; Thulasiraj, R.D.; Coles, C.L.; Sheeladevi, S.; Yanik, E.L.; Rahmathullah, L. Exposure to indoor biomass fuel and tobacco smoke and risk of adverse reproductive outcomes, mortality, respiratory morbidity and growth among newborn infants in south India. Int. J. Epidemiol. 2009, 38, 1351–1363.
[53]
Ezzati, M.; Kammen, D.M. Indoor air pollution from biomass combustion and acute respitaory infections in Kenya: An exposure-response study. Lancet 2001, 358, 619–624.
[54]
Dionisio, K.L.; Howie, S.; Fornace, K.M.; Chimah, O.; Adegbola, R.A.; Ezzati, M. Measuring the exposure of infants and children to indoor air pollution from biomass fuels in The Gambia. Indoor Air 2008, 18, 317–327.
[55]
Raaschou-Nielsen, O.; Hermansen, M.N.; Loland, L.; Buchvald, F.; Pipper, C.B.; S?rensen, M.; Loft, S.; Bisgaard, H. Long-term exposure to indoor air pollution and wheezing symptoms in infants. Indoor Air 2010, 20, 159–167.
[56]
Raaschou-Nielsen, O.; S?rensen, M.; Hertel, O.; Chawes, B.L.; Vissing, N.; B?nnelykke, K.; Bisgaard, H. Predictors of indoor fine particulate matter in infants’ bedrooms in Denmark. Environ. Res. 2011, 111, 87–93.
[57]
Belanger, K.; Beckett, W.; Triche, E.; Bracken, M.B.; Holford, T.; Ren, P.; McSharry, J.-E.; Gold, D.R.; Platts-Mills, T.A.E.; Leaderer, B.P. Symptoms of wheeze and persistent cough in the first year of life: Associations with indoor allergens, air contaminants, and maternal history of asthma. Am. J. Epidemiol. 2003, 158, 195–202.
[58]
Leaderer, B.P.; Belanger, K.; Triche, E.; Holford, T.; Gold, D.R.; Kim, Y.; Jankun, T.; Ren, P.; McSharry, J.-E.; Platts-Mills, T.A.E.; et al. Dust mite, cockroach, cat, and dog allergen concentrations in homes of asthmatic children in the northeastern United States: Impact of socioeconomic factors and population density. Environ. Health Perspect. 2002, 110, 419–425.
[59]
Hunt, A.; Crawford, J.A.; Rosenbaum, P.F.; Abraham, J.L. Levels of household particulate matter and environmental tobacco smoke exposure in the first year of life for a cohort at risk for asthma in urban Syracuse, NY. Environ. Int. 2011, 37, 1196–1205.
[60]
Jedrychowski, W.; Perera, F.; Maugeri, U.; Mrozek-Budzyn, D.; Miller, R.L.; Flak, E.; Mroz, E.; Jacek, R.; Spengler, J.D. Effects of prenatal and perinatal exposure to fine air pollutants and maternal fish consumption on the occurrence of infantile eczema. Int. Arch. Allergy Immunol. 2011, 155, 275–281.
[61]
Pogodina, C.; Brunner Huber, L.R.; Racine, E.F.; Platonova, E. Smoke-free homes for smoke-free babies: The role of residential environmental tobacco smoke on low birth weight. J. Community Health 2009, 34, 376–382.
[62]
Salmasi, G.; Grady, R.; Jones, J.; McDonald, S.D.; Knowledge Synthesis Group. Environmental tobacco smoke exposure and perinatal outcomes: A systematic review and meta-analyses. Acta Obstet. Gynecol. Scand. 2010, 89, 423–441.
[63]
Anderson, M.E.; Bogdan, G.M. Environments, indoor air quality, and children. Pediatr. Clin. N. Am. 2007, 54, 295–307.