全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

LCMS检测维生素的室内质控血清制备及可行性研究
Preparation and Feasibility Study of Internal Quality Control Serum for Vitamins Detection in LCMS

DOI: 10.12677/HJBM.2022.122008, PP. 66-72

Keywords: 维生素,质控血清,稳定性,均一性,可行性,LCMS
Vitamin
, Quality Control Serum, Stability, Uniformity, Feasibility, LCMS

Full-Text   Cite this paper   Add to My Lib

Abstract:

目的:研制稳定的维生素质控血清,用于实验室内部维生素检测的质量控制。方法:准确称取一定量的维生素A、25-羟基维生素D2、25-羟基维生素D3、维生素E和维生素K1溶于适量的二甲基亚砜中成为母液,适量添加至基质血清中,形成高、低质控血清。分装成1 ml/支,分别贮存在4℃、?20℃和?80℃环境中,以观察其在不同贮存条件下的稳定性和均一性。结果:4℃保存的质控血清,从第4天起维生素K1值迅速下降,其他维生素(A、D2、D3和E)在一周后检测值也明显下降,?20℃和?80℃保存的质控血清中几种维生素的检测值都均可稳定1年以上;均一性检测表明样品间无显著性差异(F值 < F0.05),均一性良好。结论:本研究制备的质控血清具有良好的均一性和稳定性,可用于实验室内部维生素检测的质量控制。
Objective: To develop the stable vitamin quality control serum for the quality control of vitamin testing in the laboratory. Methods: A certain amount of vitamin A, 25-hydroxyvitamin D2, 25- hydroxyvitamin D3, vitamin E and vitamin K1 was dissolved in the appropriate dimethyl sulfoxide to form mother liquor and added to the matrix serum into high- and low-quality control serum. Repacked into 1 ml/bottle and stored in 4?C, ?20?C, and ?80?C environments to observe their stability and uniformity under different storage conditions. Results: In 4?C environments, concentration of vitamin K1 in the quality control serum was decreased rapidly from day 4, and other vitamins (A, D2, D3 and E) did so after a week. The detection values of several vitamins in the quality control serum in ?20?C and ?80?C were stable for more than 1 year; uniformity tests showed no significant difference between samples (F value < F 0.05), the results showed good uniformity. Conclusion: The quality control serum prepared in this study has good uniformity and stability, and can be used for the quality control of internal laboratory vitamin testing.

References

[1]  袁小芬, 马金飞, 杨青青. 等液相色谱-串联质谱技术在维生素检测中的应用[J]. 中华检验医学杂志, 2019, 42(6): 479-483.
[2]  Depreter, B., Heijboer, A.C. and Langlois, M.R. (2013) Accuracy of Three Automated 25-Hydroxyvitamin D Assays in Hemodialysis Patients. Clinica Chimica Acta, 415, 255-260.
https://doi.org/10.1016/j.cca.2012.10.056
[3]  Heijboer, A.C., Blankenstein, M.A., et al. (2012) Accuracy of 6 Routine 25-Hydroxyvitamin D Assays: Influence of Vitamin D Binding Protein Concentration. Clinical Chemistry, 58, 543-548.
https://doi.org/10.1373/clinchem.2011.176545
[4]  Chouiali, A., Mallet, P.L., Fink, G., et al. (2017) Comparison of Two Methods for Measuring 25-OH Vitamin D in the Follow-Up of Patients after Bilio-Pancreatic Diversion Bariatric Surgery. Clinical Biochemistry, 50, 210-216.
https://doi.org/10.1016/j.clinbiochem.2016.11.010
[5]  陆彬, 闫贵贞, 戴森戈. 杭州市5000名孕妇维生素水平流行病学调查[J]. 中国妇幼保健, 2021, 36(12): 2844-2847.
[6]  中国合格评定国家认可委员会. 能力验证样品均匀性和稳定性评价指南[S]. 北京: 中国标准出版社, 2018.
[7]  Hayama, T. (2020) Matrix Effects in Mass Spectrometry Analysis. Analytical Sciences, 36, 1151.
https://doi.org/10.2116/analsci.highlights2010
[8]  中国合格评定国家认可委员会. 医学实验室质量和能力认可准则的应用要求[S]. 北京: 中国标准出版社, 2021.
[9]  中国国家标准化管理委员会. 临床实验室定量测定室内质量控制指南[S]. 北京: 中国标准出版社, 2006.
[10]  中国国家标准化管理委员会. 实验室内部研制质量控制样品的指南[S]. 北京: 中国标准出版社, 2016.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133