The ability of power system to survive the transition from preloading state to the gradual increase in load and thereafter reach an acceptable operational condition is an indication of transient stability of the system. The study analyzed load shedding scheme through the use of empirical measurement tools and load-flow simulation techniques. It was geared towards determining effective load shedding strategies to reduce unnecessary overload in order to achieve dynamic stability of the electric power network in the Export Free Trade Zone, Calabar, Nigeria. From the tests and the measurements taken, it was observed that the real and reactive powers from the generator and the mechanical power from the turbine engine were stable when the load shedding controller was switched on, as compared to when it was off. The engine speed, the bus-bar frequency and the output voltage of the generator stabilized within a shorter time (about 8 seconds) when the controller was switched on than when it was on the off condition. Also, there were noticeable fluctuations in the speed of the remaining two generators. It became stable at about 12 seconds after the loss. The variations were 0.3 per cent of the nominal speed value. The excitation voltage fluctuated from 1.2 (pu) to 4.5 (pu) when the bus voltage dipped as a result of additional load. It then came down and stabilized at 1.8 (pu) after few swings. This confirmed that the stability of power system is much enhanced when load shedding controllers are effectively configured on the network.
References
[1]
Tuan, T.Q. and Fandino, J. (2007) Emergency Load Shedding to Avoid Risks of Voltage Instability Using Indicators. IEEE Transactions on Power System, 9, 2-25.
[2]
Kirby, B.J. (2002) Frequency Control Concerns in the North American Electric Power System. Oak Ridge National Laboratory, Electric Power Group. https://doi.org/10.2172/885842
[3]
Flores, R.M., McDonell, V.G. and Samuelsen, G.S. (2003) Impact of Ethane & Propane Variation in Natural on the Performance of a Model Gas Turbine Combustor. Proceeding of ASME Turbo Expo, 125, 701-708.
[4]
Lundsager, P. (2001) Isolated System with Wind Power Main Report. National Laboratory, Denmark.
[5]
Hassan Ghasemi, H. (2006) On-Line Monitoring and Oscillatory Stability Margin Prediction in Power System Identification. A Ph.D Thesis Presented to the University of Waterloo, Electrical and Computer Engineering, Waterloo, Ontario, Canada.
[6]
Dai, J.J. (2005) Intelligent Bload Shedding Need for a Fast and Optimal Solution. TECHNIP Operation Technology, Inc., Paris.
[7]
Kodsi, S.K. (2005) Accounting for the Effects of Power System Controllers and Stability on Power Dispatch and Electricity Market Prices. A Ph.D Thesis Presented to the University of Waterloo, Canada.
[8]
Dong, Z.Y. and Hill, D. (2005) A Power System Control Scheme Based on Security Visualization in Parameter Space. School of Information Technology and Electrical Engineering. The University of Queensland. St Lucia, QLD 4072, Australia.
[9]
Rogers, G.C. (2001) Performance of Gas Turbines with Real Gas Effects. Institute of Mechanical Engineers’ Publication, Philadelphia, USA.
[10]
Ariyo, F.K. (2013) Investigation of Nigerian 330KV Electrical Network with Distribution Generation Penetration: Determination and Probabilities Analysis. American Journal of Electrical Power and Energy Systems, 2, 7-22. https://doi.org/10.11648/j.epes.20130201.12
[11]
Carpentier, J. (2001) Application of a New Security Concept in Optimal Power Flows to Congestion Management. Proceedings of the 6th International Workshop on Electric Power System Control Centre, Opio, France, 10-13 June 2001.
[12]
Bassey, D.E. and Okon, B.E. (2015) Comparative Studies between Reduction of Discrete Frequency Ranges and Radiated Sound Levels (A Case Study of 50 kVA Diesel Engine Cooling Fan). International Journal of Engineering Research and Technology, 4, 9.