-  2011 

锅炉安装防磨梁效果及热流密度测试分析 - -

Keywords: 防磨梁,热流密度,CFB锅炉,水冷壁 anti-wearing device,heat flux density,CFB boilers,water cooled wall panels

Full-Text   Cite this paper   Add to My Lib

Abstract:

针对引进型CFB锅炉存在水冷壁磨损严重的问题,提出在锅炉基建期间安装水冷壁多阶防磨梁装置,装置运行1 a后,测定防磨梁的防磨效果,同时利用热流计对安装防磨梁后热流密度的变化进行了测试分析。结果表明防磨梁具有良好的防磨效果,延长了水冷壁的使用寿命。 In order to resolve the serious wearing problems of water cooled wall panels of CFB boilers,provide the methods of installing multi-stage anti-wearing device in CFB boilers during capital construction.Test the anti-wear effect after one year later,meanwhile,measure the change of heat flux density using heat-flow meter.The results show that this anti-wearing device has a good use effectiveness,and can prolong the working life of water cooled wall panels