Comparative Study of Linear and Non-Linear Controls of Three-Phase Shunt Active Filters for Improving the Quality of Electrical Energy

DOI: 10.4236/epe.2019.113009, PP. 149-166

Keywords: Power Quality, Active Three-Phase Shunt Filter, Non-Linear Control, Linear Control

Full-Text   Cite this paper   Add to My Lib

Abstract:

The aim of this work is to comparatively study two types of control of a three-phase shunt active filter (TSAF) in order to realize a system of depollution of electrical networks so as to improve the quality of electrical energy. We used two TSA control models which differ in the method of disturbed currents detection, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives more promising results than the linear control method. When connecting a non-linear load (televisions, lamps, variable speed drives, etc.) directly to the public distribution network, the non-linear nature of the load causes the source current to be deformed due to the presence of harmonic currents and voltages. These harmonics thus generate a high reactive power, and therefore considerable electrical losses in the network. One of the solutions to reduce losses on the electricity grid is to incorporate an electronic circuit called a filter into the electricity grid. This work carried out a comparative study of two types of control of a three-phase shunt active filter (TSAF) in order to carry out a system for cleaning up electricity networks in order to improve the quality of electrical energy. We used two TSA control models that differ in the method of detecting disturbed currents, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives better results than the linear control method.

References

[1]  Gupta, S., Das, R.F. and Ashraful, B.C. (2016) A Comparative Study on Harmonics of Different Electric Bulbs. American Journal of Engineering Research (AJER), 5, 156-166.
[2]  Abdoulkarimoun, D. (2018) Etudes des perturbations Harmonique et leurs traitements dans le réseau électrique: Cas du réseau BT de la ville de Niamey. PhD Thesis, Abdou Moumouni University, Niger.
[3]  Mohamad, A.E.A. (2002) Contribution à l’Etude des Compensateurs Actifs des Réseaux Electriques Basse Tension. PhD Thesis, Louis Pasteur University, Strasbourg.
[4]  Hind, D. (2007) Filtrage actif de puissance, PhD Thesis, Mentouri University, Constantine.
[5]  Abdelhamid, H. (2010) Contribution à l’étude des filtres hybrides de puissance utilises pour améliorer la qualité de l’énergie dans le réseau électrique de distribution. PhD Thesis, Québec University, Canada.
[6]  Shraddha, D., Jalaja, G.P.K., Manashri, Y. and Tuljapurkar, M.D. (2015) Detection of Harmonics in Distribution System Using FFT with Case Studies. International Journal for Scientific Research and Development, 3, 481-484.
[7]  Antoni, H.N. (2017) Commande de filtres actifs parallèles sur un réseau fortement perturbé. PhD Thesis, Toulouse University, France.
[8]  Sina, S. (2002) Etude d’une commande nonlinéaire sur un filtre actif. PhD Thesis, Québec University, Canada.
[9]  Mohamed, M. (2007) Validation des techniques de commande d’un filtre actif parallèle. PhD Thesis, Québec University, Canada.
[10]  Slotine, J.-J. and Li, W.P. (1991) Applied Nonlinear Control. Prentice Hall, Upper Saddle River.

Full-Text