Abstract:
针对已有电容层析成像(ECT)技术的独立电容较少、反问题方程数过少及其解不唯一的问题,提出了一种48电极的ECT系统模型及模型组合电极策略。首先,通过组合电极策略将多个临近电极组合成一个电极,使原48电极ECT系统配置为8、12、16或24电极ECT系统,从而获得绕管道轴心旋转不同角度的多个具有相同电极数ECT系统;然后,通过有限元仿真和图像重构算法成像。该模型可使ECT反问题的方程组中电容数成倍增加,从而改善了ECT反问题方程组因方程数过少而引起的解不唯一的不适定问题,解决了增加电极数而电极片面积却减小引起的电容值减小问题。仿真结果表明:所提出的ECT模型及其组合电极策略可重构图像,并能通过增加测量电容数提高重构图像质量;在系统加入10%标准差白噪声时,图像错误率下降约6%。
A model of electrical capacitance tomography (ECT) system with configurable 48 electrodes and a strategy to combine electrodes are proposed to increase the capacitances of the current ECT system and to solve the equations of the ECT inverse problem. The strategy combines some adjacent electrodes as one electrode so that the ECT system with 48 electrodes is reconfigured as a ECT system with less electrodes, such as 8 electrodes,12 electrodes, 16 electrodes or 24 electrodes. Several ECT systems with the same number of electrodes and the different rotation angles around the pipeline are obtained. Then the finite??element modeling and an image reconstruction algorithm are adopted for imaging. The model increases the number of capacitances in the equations of the ECT inverse problem, thus the ill??posedness of the equations of the ECT inverse problem caused by less equations is improved. The model also solves the problem that the capacitance value will decrease when the number of electrodes increases. Simulation results show that the proposed model and strategy can reconstruct images and improve the fidelity of reconstructed images by increasing the number of capacitances, and the error rate of images decreases by about 6% when a white noise with a standard deviation of 10% is added into the system
[1] | [1]HUANG S M, PLASKOWSKI A B, XIE C G, et al. Capacitance??based tomographic flow imaging system [J]. Electronics Letters, 1988, 24(7): 418??419. |
[2] | [7]XIE C G, PLASKOWSKI A, BECK M S. 8??electrode capacitance system for two??component flow identification: part 1Tomographic flow imaging [J]. IEE Proceeding, 1989, 136(4): 173??183. |
[3] | [2]XIE C G, HUANG S M, HOYLE B S, et al. Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors [J]. IEE Proceedings: G, 1992, 139(1): 89??98. |
[4] | [3]ISAKSEN O. A review of reconstruction techniques for capacitance tomography [J]. Measurement Science Technology, 1996, 7(3): 325??337. |
[5] | [4]DYAKOWSKI T, JEANMEURE L F C, JAWORSKI A J. Applications of electrical tomography for gas??solids and liquid??solids flows: a review [J]. Power Technology, 2000, 112(3): 174??192. |
[6] | [5]BERNIERI A, BETTA G, FERRIGNO L, et al. Crack depth estimation by using a multi??frequency ECT method [J]. IEEE Transactions on Instrumentation and Measurement, 2013, 62(3): 544??552. |
[7] | [6]彭黎辉, 陆耿, 杨五强. 电容成像图像重建算法原理及评价 [J]. 清华大学学报:自然科学版, 2004, 44(4): 478??484. |
[8] | PENG lihui, LU Geng, YANG Wuqiang. Image reconstruction algorithms for electrical capacitance tomography state of the art [J]. Journal of Tsinghua University: Science & Technology, 2004,44(4):478??484. |
[9] | [8]YANG W Q, SPINK D M, YORK T A, et al. An image??reconstruction algorithm based on Landweber’s iteration method for electrical??capacitance tomography |
[10] | [J]. Measurement Science and Technology, 1999, 10(11): 1065??1069. |
[11] | [9]SOLEIMANI M, VAUHKONEN M, YANG W Q, et al. Dynamic imaging in electrical capacitance tomography and electromagnetic induction tomography using a Kalman filter [J]. Measurement Science Technology, 2007, 18: 3287??3294. |
[12] | [12]PENG Lihui, YE Jiamin, LU Geng, et al. Evaluation of effect of number of electrodes in ECT sensors on image quality [J]. IEEE Sensors Journal, 2012, 12(5): 1554??1565. |
[13] | [13]LIU Zhijian, BABOUT L, BANASIAK R, et al. Effectiveness of rotatable sensor to improve image accuracy of ECT system [J]. Flow Measurement and Instrumentation, 2010, 21(3): 219??227. |
[14] | [10]WANG Huaxiang, XIN Shan, ZHANG Xuehui. New progress of the digital electrical capacitance tomography system for gas/liquid two phase flow [C]∥ ST 2009??International Workshop on Imaging. Piscataway, NJ, USA: IEEE, 2009: 37??40. |
[15] | [11]YANG W Q. Design of electrical capacitance tomography sensors [J]. Measurement Science Technology, 2010, 21(4): 1??3. |
[16] | [16]YANG Yunjie, PENG Lihui. Data pattern with ECT sensor and its impact on image reconstruction [J]. IEEE Sensors Sjournal, 2013, 13(5): 1582??1593. |
[17] | [14]YANG Yunjie, PENG Lihui. A configurable electrical capacitance tomography system using a combining electrode strategy [J]. Measurement Science Technology, 2013, 24(7): 1??11. |
[18] | [15]ALME K J, MYLVAGANAM S. Comparison of different measurement protocols in electrical capacitance tomography using simulations [J]. IEEE Transactions on Instrumentation and Measurement, 2007, 56(6): 2119??2130. |