全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2017 

计算机导航及机器人技术辅助膝关节单髁置换术的研究进展

DOI: doi:10.7507/1002-1892.201609028

Keywords: 膝关节单髁置换术, 计算机导航, 机器人辅助导航系统

Full-Text   Cite this paper   Add to My Lib

Abstract:

目的 总结计算机导航及机器人技术在膝关节手术中的分类,以及辅助膝关节单髁置换术(unicompartmental knee arthroplasty,UKA)的发展、手术适应证和禁忌证、临床疗效及最新进展。 方法 广泛查阅计算机导航及机器人技术辅助 UKA 的相关文献,并进行研究和总结分析。 结果 近年来 UKA 在治疗单间室膝关节骨性关节炎方面取得了令人满意的效果,随着计算机导航及手术机器人技术的飞速发展并逐渐与临床相结合,计算机导航及机器人技术联合 UKA 大大提高了术中截骨的精度及假体植入准确率,术后功能恢复良好的同时明显提高了单髁假体的使用寿命。 结论 计算机导航及机器人技术辅助 UKA 较传统 UKA 提高了假体植入精确度,术后早期疗效满意,但长期疗效仍有待进一步观察

References

[1]  1. ?Jenny JY, Boeri C. Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation. Knee Surg Sports Traumatol Arthrosc, 2003, 11(1): 40-45.
[2]  2. Muller PE, Pellengahr C, Witt M, et al. Influence of minimally invasive surgery on implant positioning and the functional outcome for medial unicompartmental knee arthroplasty. J Arthroplasty, 2004, 19(3): 296-301.
[3]  3. Voss F, Sheinkop MB, Galante JO, et al. Miller-Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluations. J Arthroplasty, 1995, 10(6): 764-771.
[4]  6. Lovell S, Crispin D. A prototype optical tracking system: Investigation and development. Christchurch, New Zealand: University of Canterbury, 2009.
[5]  12. Krackow KA, Phillips MJ, Bayers-Thering M, et al. Computer-assisted total knee arthroplasty: navigation in TKA. Orthopedics, 2003, 26(10): 1017-1023.
[6]  13. Dowd GS, Somayaji HS, Uthukuri M. High tibial osteotomy for medial compartment osteoarthritis. Knee, 2006, 13(2): 87-92.
[7]  14. Yang ZY, Chen W, Li CX, et al. Medial Compartment Decompression by Fibular Osteotomy to Treat Medial Compartment Knee Osteoarthritis: A Pilot Study. Orthopedics, 2015, 38(12): e1110-1114.
[8]  15. Hernigou P, Deschamps G. Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res, 2004, 42(3): 161-165.
[9]  18. Jenny JY. Navigated unicompartmental knee replacement. Orthopedics, 2005, 28(10 Suppl): s1263-1267.
[10]  19. Keene G, Simpson D, Kalairajah Y. Limb alignment in computerassisted minimally-invasive unicompartmental knee replacement. J Bone Joint Surg (Br), 2006, 88(1): 44-48.
[11]  21. Lonner JH. Indications for unicompartmental knee arthroplasty and rationale for robotic arm-assisted technology. Am J Orthop (Belle Mead NJ), 2009, 38(2 Suppl): 3-6.
[12]  22. Kozinn SC, Scott R. Unicondylar knee arthroplasty. J Bone Joint Surg (Am), 1989, 71(1): 145-150.
[13]  28. Dunbar NJ, Roche MW, Park BH, et al. Accuracy of dynamic tactile-guided unicompartmental knee arthroplasty. Arthroplasty, 2012, 27(5): 803-808.e1.
[14]  31. Weber P, Crispin A, Schmidutz F, et al. Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc, 2013, 21(11): 2453-2461.
[15]  32. Lonner JH, Smith JR, Picard F, et al. High degree of accuracy of a novel image-free handheld robot for unicondylar knee arthroplasty in a cadaveric study. Clin Orthop Relat Res, 2015, 473(1): 206-212.
[16]  35. Cossey AJ, Spriggins AJ. The use of computer-assisted surgical navigation to prevent malalignment in unicompartmental knee arthroplasty. J Arthroplasty, 2005, 20(1): 29-34.
[17]  36. Hansen DC, Kusuma SK, Palmer RM, et al. Robotic guidance does not improve component position or short-term outcome in medial unicompartmental knee arthroplasty. J Arthroplasty, 2014, 29(9): 1784-1789.
[18]  47. Rosenberger RE, Fink C, Quirbach S, et al. The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc, 2008, 16(12): 1133-1140.
[19]  49. Moschetti WE, Konopka JF, Rubash HE, et al. Can Robot-Assisted Unicompartmental Knee Arthroplasty Be Cost-Effective? A Markov Decision Analysis. J Arthroplasty, 2016, 31(4): 759-765.
[20]  4. Picard F, Moody J, Jaramaz B, et al. A classification proposal for computer-assisted knee systems//International Conference on Medical Image Computing and Computer-Assisted Intervention-MICCAI. Berlin, Heidelberg: Springer, 2000, 1935: 1145-1151.
[21]  5. Siebert W, Mai S, Kober R, et al. Technique and first clinical results of robot-assisted total knee replacement. Knee, 2002, 9(3): 173-180.
[22]  7. Hagag B, Abovitz R, Kang H, et al. RIO: Robotic-arm interactive orthopedic system MAKOplasty: User interactive haptic orthopedic robotics. Surgical Robotics. New York: Springer, 2011: 219-246.
[23]  10. Maillet P, Nahum B, Blondel L, et al. BRIGIT, a robotized tool guide for orthopedic surgery//International Conference on Robotics and Automation. Barcelona, Spain: IEEE, 2005: 211-216.
[24]  11. Stiehl JB, Konermann WH, Haaker RG, et al. Navigation and MIS in Orthopedic Surgery. Heidelberg: Springer Medizin Verlag, 2007: 36-43, 88-94.
[25]  37. Valenzuela GA, Jacobson NA, Geist DJ, et al. Implant and limb alignment outcomes for conventional and navigated unicompartmental knee arthroplasty. J Arthroplasty, 2013, 28(3): 463-468.
[26]  38. Lim MH, Tallay A, Bartlett J. Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc, 2009, 17(4): 341-346.
[27]  39. Konyves A, Willis-Owen CA, Spriggins AJ. The long-term benefit of computer-assisted surgical navigation in unicompartmental knee arthroplasty. J Orthop Surg Res, 2010, 5: 94.
[28]  48. Martinez-Carranza N, Weidenhielm L, Crafoord J, et al. Deviation between navigated and final 3-dimensional implant position in mini-invasive unicompartmental knee arthroplasty: a pilot study in 13 patients. Acta Orthop, 2012, 83(6): 625-628.
[29]  8. Wolf A, Jaramaz B, Lisien B, et al. MBARS: mini bone attached robotic system for joint arthroplasty. Int J Med Robot, 2005, 2: 101-121.
[30]  9. Cobb J, Henckel J, Gomes P, et al. Hands-on robotic unicompartmental knee replacement: A prospective, randomised controlled study of the acrobot system. J Bone Joint Surg (Br), 2006, 88(2): 188-197.
[31]  16. Jeer PJ, Keene GC, Gill P. Unicompartmental knee arthroplasty: an intermediate report of survivorship after the introduction of a new system with analysis of failures. Knee, 2004, 11(5): 369-374.
[32]  17. Koshino T, Morii T, Wada J, et al. Unicompartmental replacement with the Marmor Modular knee: operative procedure and results. Bull Hosp Jt Dis Orthop Inst, 1991, 51(2): 119-131.
[33]  20. Confalonieri N, Manzotti A. Mini-invasive computer assisted bi-unicompartimental knee replacement. Int J Med Robot, 2005, 1(4): 45-50.
[34]  23. Kuipers BM, Kollen BJ, Bots PC, et al. Factors associated with reduced early survival in the Oxford phase III medial unicompartment knee replacement. Knee, 2010, 17(1): 48-52.
[35]  24. 朱伟民. 髌股关节退变对老年膝关节单髁置换术疗效的影响. 中国老年学杂志, 2014, 34(12): 3345-3347.
[36]  25. Boissonneault A, Pandit H, Pegg E, et al. No differencein survivorship after unicompartmental knee arthroplasty with or without an intact anterior cruciate ligament. Knee Surg SportsTraumatol Arthrosc, 2013, 21(11): 2480-2486.
[37]  26. Murray DW, Pandit H, Weston-Simons JS, et al. Does body mass index affect the outcome of unicompartmental knee replacement. Knee, 2013, 20(6): 461-465.
[38]  27. Seng CS, Ho DC, Chong HC, et al. Outcomes and survivorship of unicondylar knee arthroplasty in patients with severe deformity. Knee Surg Sports Traumatol Arthrosc, 2014. [Epub ahead of print].
[39]  29. Ma B, Rudan J, Chakravertty R, et al. Computer-assisted FluoroGuide navigation of unicompartmental knee arthroplasty. Can J Surg, 2009, 52(5): 379-385.
[40]  30. Manzotti A, Cerveri P, Pullen C, et al. Computer-assisted unicompartmental knee arthroplasty using dedicated software versus a conventional technique. Int Orthop, 2014, 38(2): 457-463.
[41]  33. Saragaglia D, Picard F, Refaie R. Navigation of the tibial plateau alone appears to be sufficient in computer-assisted unicompartmental knee arthroplasty. Int Orthop, 2012, 36(12): 2479-2483.
[42]  34. Pearle AD, O’Loughlin PF, Kendoff D. Robot-assisted unicompartmental knee arthroplasty. J Arthroplasty, 2010, 25(2): 230-237.
[43]  40. 戴尅戎. 计算机辅助关节置换术的现状和展望. 继续医学教育, 2007, 21(12): 8-10.
[44]  41. Thein R, Khamaisy S, Zuiderbaan HA, et al. Lateral robotic unicompartmental knee arthroplasty. Sports Med Arthrosc, 2014, 22(4): 223-228.
[45]  42. Argenson JN, Parratte S, Bertani A, et al. Long-term resultswith a lateral unicondylar replacement. Clin Orthop Relat Res, 2008, 466(11): 2686-2693.
[46]  43. Jung KA, Kim SJ, Lee SC, et al. Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee, 2010, 17(6): 387-391.
[47]  44. Seon JK, Song EK, Park SJ, et al. Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty, 2009, 24(3): 351-357.
[48]  45. Zhang Z, Zhu W, Zhu L, et al. Superior alignment but no difference in clinical outcome after minimally invasive computer-assisted unicompartmental knee arthroplasty (MICA-UKA). Knee Surg Sports Traumatol Arthrosc, 2016, 24(11): 3419-3424.
[49]  46. Jenny JY, Ciobanu E, Boeri C. The rationale for navigated minimally invasive unicompartmental knee replacement. Clin Orthop Relat Res, 2007, 463: 58-62.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133