-  2016 

棘突间撑开器治疗退变性腰椎管狭窄症的研究进展

DOI: doi:10.7507/1002-1892.20160264

Keywords: 退变性椎管狭窄症, 棘突间撑开器, 动态固定

Full-Text   Cite this paper   Add to My Lib

Abstract:

目的对棘突间撑开器(interspinous distraction devices,IDD)治疗退变性腰椎管狭窄症(degenerative lumbar spinal stenosis,DLSS)的研究现状作一综述。 方法查阅近年国内外IDD治疗DLSS的相关文献,并进行分析总结。 结果IDD治疗DLSS的短期疗效优于保守治疗,与减压术或融合术无显著差异。IDD并发症发生率高,虽然并不显著影响手术疗效,但会提高患者医疗成本。 结论IDD为保守治疗无效而又不能耐受开放手术的DLSS患者提供了治疗选择,但其耐用性及长期疗效还需进一步研究观察

References

[1]  1. Hur JW,Kim SH,Lee JW,et al.Clinical analysis of postoperative outcome in elderly patients with lumbar spinal stenosis.J Korean Neurosurg Soc,2007,41(3):157-160.
[2]  3. Lehmann TR,Spratt KF,Tozzi JE,et al.Long-term follow-up of lower lumbar fusion patients.Spine (Phila Pa 1976),1987,12(2):97-104.
[3]  4. Okuda S,Oda T,Yamasaki R,et al.Repeated adjacent-segment degeneration after posterior lumbar interbody fusion.J Neurosurg Spine,2014,20(5):538-541.
[4]  16. Zucherman JF,Hsu KY,Hartjen CA,et al.A multicenter,prospective,randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication:two-year follow-up results.Spine (Phila Pa 1976),2005,30(12):1351-1358.
[5]  18. L?nne G,Johnsen LG,Rossvoll I,et al.Minimally invasive decompression versus x-stop in lumbar spinal stenosis:a randomized controlled multicenter study.Spine (Phila Pa 1976),2015,40(2):77-85.
[6]  19. L?nne G,Johnsen LG,Aas E,et al.Comparing cost-effectiveness of X-stop to minimally invasive decompression in lumbar spinal stenosis:a randomized controlled trial.Spine (Phila Pa 1976),2015,40(8):514-520.
[7]  20. Patil CG,Sarmiento JM,Ugiliweneza B, et al.Interspinous device versus laminectomy for lumbar spinal stenosis:a comparative effectiveness study.Spine J,2014,14(8):1484-1492.
[8]  21. Burnett MG,Stein SC,Bartels RH.Cost-effectiveness of current treatment strategies for lumbar spinal stenosis:nonsurgical care,laminectomy,and X-STOP.J Neurosurg Spine,2010,13(1):39-46.
[9]  22. Beyer F,Yagdiran A,Neu P,et al.Percutaneous interspinous spacer versus open decompression:a 2-year follow-up of clinical outcome and quality of life.Eur Spine J,2013,22(9):2015-2021.
[10]  25. Patel VV,Nunley PD,Whang PG,et al.Superion? InterSpinous Spacer for treatment of moderate degenerative lumbar spinal stenosis:durable three-year results of a randomized controlled trial.J Pain Res,2015,8:657-662.
[11]  26. Bini W,Miller LE,Block JE.Minimally invasive treatment of moderate lumbar spinal stenosis with the superion? interspinous spacer.Open Orthop J,2011,5:361-367.
[12]  29. Hrabálek L,Wanek T,Macha? J,et al.Percutaneous interspinous dynamic stabilization (in-space) in patients with degenerative disease of the lumbosacral spine-a prospective study.Rozhl Chir,2012,91(6):311-316.
[13]  30. Kantelhardt SR,T?r?k E,Gempt J,et al.Safety and efficacy of a new percutaneously implantable interspinous process device.Acta Neurochir (Wien),2010,152(11):1961-1967.
[14]  31. Richter A,Schütz C,Hauck M,et al.Does an interspinous device (Coflex) improve the outcome of decompressive surgery in lumbar spinalstenosis? One-year follow up ofprospective case control study of 60 patients.Eur Spine J,2010,19(2):283-289.
[15]  32. Davis RJ,Errico TJ,Bae H,et al.Decompression and Coflex interlaminar stabilization compared with decompression and instrumentedspinal fusion for spinal stenosis and low-grade degenerative spondylolisthesis:two-year results from the prospective,randomized,multicenter,Food and Drug Administration Investigational Device Exemption trail.Spine (Phila Pa 1976),2013,38(18):1529-1539.
[16]  6. Bono CM,Vaccaro AR.Interspinous process devices in the lumbar spine.J Spinal Disord Tech,2007,20(3):255-261.
[17]  11. Marsh GD,Mahir S,Leyte A.A prospective randomised controlled trial to assess the efficacy of dynamic stabilisation of the lumbar spine with the Wallis ligament.Eur Spine J,2014,23(10):2156-2160.
[18]  12. Daentzer D,Hurschler C,Seehaus F,et al.Posterior dynamic stabilization in the lumbar spine-24 months results of a prospective clinical and radiological study with an interspinous distraction device.BMC Musculoskelet Disord,2016,17:90.
[19]  13. Sénégas J,Vital JM,Pointillart V,et al.Clinical evaluation of a lumbar interspinous dynamic stabilization device (the Wallis sys-tem) with a 13-year mean follow-up.Neurosurg Rev,2009,32(3):335-342.
[20]  14. Miller JD,Miller MC,Lucas MG.Erosion of the spinous process:a potential cause of interspinous process spacer failure.J Neurosurg Spine,2010,12(2):210-213.
[21]  15. Chung KJ,Hwang YS,Koh SH.Stress fracture of bilateral posterior facet after insertion of interspinous implant.Spine (Phila Pa 1976),2009,34(10):E380-383.
[22]  23. Surace MF,Fagetti A,Fozzato S,et al.Lumbar spinal stenosis treatment with Aperius perclid interspinous system.Eur Spine J,2012,21 Suppl 1:S69-74.
[23]  24. Galarza M,Fabrizi AP,Maina R,et al.Degenerative lumbar spinal stenosis with neurogenic intermittent claudication and treatment with the Aperius PercLID System:a preliminary report.Neurosurg Focus,2010,28(6):E3.
[24]  27. Shabat S,Miller LE,Block JE,et al.Minimally invasive treatment of lumbar spinal stenosis with a novel interspinous spacer.Clin Interv Aging,2011,6:227-233.
[25]  28. Patel VV,Whang PG,Haley TR,et al.Superion interspinous process spacer for intermittent neurogenic claudication secondary to moderate lumbar spinal stenosis:two-year results from a randomized controlled FDA-IDE pivotal trial.Spine (Phila Pa 1976),2015,40(5):275-282.
[26]  2. F?rsth P,ólafsson G,Carlsson T,et al.A randomized,controlled trial of fusion surgery for lumbar spinal stenosis.N Engl J Med,2016,374(15):1413-1423.
[27]  5. Lee SH,Seol A,Cho TY,et al.A systematic review of interspinous dynamic stabilization.Clin Orthop Surg,2015,7(3):323-329.
[28]  7. Sénégas J.Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments:the Wallis system.Eur Spine J,2002,11 Suppl 2:S164-169.
[29]  8. Sénégas J.Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments:the Wallis system.Eur Spine J,2002,11 Suppl 2:S164-169.
[30]  9. Hirsch C,Breque C,Ragot S,et al.Biomechanical study of dynamic changes in L4-L5 foramen surface area in flexion and extension after implantation of four interspinous process devices.Orthop Traumatol Surg Res,2015,101(2):215-219.
[31]  10. Wilke HJ,Drumm J,H?ussler K,et al.Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure.Eur Spine J,2008,17(8):1049-1056.
[32]  17. Str?mqvist BH,Berg S,Gerdhem P,et al.X-stop versus decompressive surgery for lumbar neurogenic intermittent claudication:randomized controlled trial with 2-year follow-up.Spine (Phila Pa 1976),2013,38(17):1436-1442.
[33]  33. Bae HW,Davis RJ,Lauryssen C,et al.Three-year follow-up of the prospective,randomized,controlled trial of coflex interlaminar stabilization vs instrumented fusion in patients with lumbar stenosis.Neurosurgery,2016,79(2):169-181.
[34]  34. Caserta S,La Maida GA,Misaggi B,et al.Elastic stabilization alone or combined with rigid fusion in spinal surgery:a biomechanical study and clinical experience based on 82 cases.Eur Spine J,2002,11 Suppl:S192-197.
[35]  35. Ryu SJ,Kim IS.Interspinous implant with unilateral laminotomy for bilateral decompression of degenerative lumbar spinal stenosis in elderly patients.J Korean Neurosurg Soc,2010,47(5):338-344.
[36]  36. Ha KY,Seo JY,Kwon SE,et al.Posterior dynamic stabilization in the treatment of degenerative lumbar stenosis:validity of its rationale.J Neurosurg Spine,2013,18(1):24-31.
[37]  37. Park SC,Yoon SH,Hong YP,et al.Minimum 2-year follow-up result of degenerative spinal stenosis treated with interspinous u (coflex).J Korean Neurosurg Soc,2009,46(4):292-299.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133