全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2016 

“All-on-4”在不同骨质条件下应力分布的三维有限元分析
Three-dimensional Finite Element Analysis of Stress Distribution under Different Bone Conditions in All-on-4 Therapy

DOI: 10.13701/j.cnki.kqyxyj.2016.12.007

Keywords: All-on-4,骨密度,应力分析,三维有限元,
All-on-4
,Bone density, Stress analysis, Three-dimensional finite element

Full-Text   Cite this paper   Add to My Lib

Abstract:

摘要 目的:建立“All-on-4”种植三维有限元模型,研究不同骨质条件下远中种植体倾斜角度及修复体悬臂梁长度的变化对种植体及周围骨组织应力分布的影响,为临床提供依据。方法:CBCT扫描无牙颌下颌骨标本,将获取的DICOM数据图像,导入Mimics软件,进行三维重建,运用Geomagic studio软件进行实体化处理,利用Unigraphics及ANSYS Workbench软件模拟“All-on-4”种植建立三维有限元模型。设定修复体牙弓长度不变,在Ⅱ、Ⅲ类骨条件下,分别调整两个远中倾斜种植体倾斜角度及悬臂梁长度,在双侧悬臂梁末端施加150 N静载荷,对比分析种植体及周围骨组织应力分布规律。结果:当远中种植体倾斜角度为30°、45°及60°时,修复体悬臂梁长度分别为10.8 mm、8 mm及6.3 mm,Ⅱ类骨质条件下皮质骨应力峰值分别为26.8 MPa、23.5 MPa及16.3 MPa,Ⅲ类骨质条件下皮质骨应力峰值分别为40 MPa、29 MPa及21.8 MPa。结论:骨密度越低,种植体周围皮质骨应力越大;在牙弓长度相同的情况下,增大远中倾斜种植体的植入角度,可以减小修复体悬臂梁的长度,能有效地减小种植体及周围骨组织应力

References

[1]  Babbush CA, Kutsko GT, Brokloff J. The All-on-Four Immediate Function Treatment Concept With NobelActive Implants: A Retrospective Study [J]. J Oral Implantol, 2011,37(4)∶431-445
[2]  Malhotra AO, Padmanabhan TV, Mohamed K, et al. Load transfer in tilted implants with varying cantilever lengths in an all-on-four situation [J]. Aust Dent J, 2012, 57(3)∶440-445
[3]  Mlo P, de Araújo Nobre M, Lopes A, et al. A Longitudinal Study of the Survival of All-on-4 implants in the mandible with up to 10 years of follow-up [J]. J Am Dental Assoc, 2011, 142(3)∶310-320
[4]  Mlo P, de Araújo Nobre M, Lopes A. Immediate Rehabilitation of Completely Edentulous Arches with a Four-Implant Prosthesis Concept in Difficult Conditions: An Open Cohort Study with a Mean Follow-up of 2 years [J]. Int J Oral Maxillofac Implants, 2012, 27(5)∶1177-1190
[5]  赵旭,邸萍,林野,等. “All-on-4”无牙颌种植即刻修复技术的初步临床观察[J].北京大学学报(医学版),2014,46(5)∶720-726
[6]  邸萍,林野,李健慧,等. “All-on-4”种植即刻修复技术的临床应用研究[J].中华口腔医学杂志,2011,16(1)∶61-61
[7]  Amet EM, Uehlein C. Alveolar nerve repositioning with rescue implants for management of previous treatment. A clinical report [J]. J Prosthodont,2013,22(8)∶633-640
[8]  Kitamura E, Stegaroiu R, Nomura S, et al. Influence of marginal bone resorption on stress around an implant a three-dimensional finite element analysis [J]. J Oral Rehabil,2005,32(4)∶279-286
[9]  Takahashi T, Shimamura I, Sakurai K. Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with All-on-4 Concept [J]. J Prosthodont Res, 2010, 54(1)∶179-184
[10]  Brunski JB, et al. Biomechanical aspects of the optimal number of implants to carry a cross-arch full restoration [J]. Eur J Oral Implantol, 2014, 7(2)∶111-131
[11]  Bevilacqua M, Tealdo T, Menini M, et al. The influence of cantilever length and implant inclination on stress distribution in maxillary implant supported fixed dentures [J]. J Prosthet Dent, 2011, 105(1)∶6-13
[12]  Danza M, Quaranta A, Carinci F. Biomechanical evaluation of dental implants in D1 and D4 bone by Finite Element Analysis [J]. Minerva Stomatol,2010,59(6)∶305-313
[13]  熊安洲,陈菁,黄莺,等.单冠种植系统受力状况分析及疲劳寿命测定——转角基台vs转角冠[J].口腔医学研究,2014,30(4)∶314-317
[14]  Málo P, Rangert B, Nobre M. “All-on-four” immediate-function concept with Brnemark System implants for completely edentulous mandibles: a retrospective clinical study [J]. Clin Implant Dent Relat Res,2003,5(1)∶2-9
[15]  Rho JY, Ashman RB, Turner CH. Young’s modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements [J]. J Biomech,1993,26(2)∶111-119
[16]  王煜婷,张少峰,董岩,等.All-on-4种植体参数对周围骨应力影响的三维有限元分析[J].实用口腔医学杂志,2014,30(2)∶193-197

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133