全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2016 

ProTaperNext锉和WaveOne锉根管成形能力的对比研究
Comparative Study of Shaping Ability between ProTaper Next and WaveOne

DOI: 10.13701/j.cnki.kqyxyj.2016.09.008

Keywords: ProTaperNext,WaveOne,弯曲根管,成形能力,
ProTaper Next
,WaveOne,Curved root canal,Shapingability

Full-Text   Cite this paper   Add to My Lib

Abstract:

摘要 目的:比较机用ProTaperNext和WaveOne在弯曲树脂模拟根管中的成形能力。方法:选取统一规格的透明树脂模拟根管40个,将其随机分为2组,分别使用ProTaperNext和WaveOne锉以冠向下技术预备两组树脂模拟根管。使用ImagePro Plus软件测量根管弯曲半径和弯曲度的变化以及各测量点去除树脂量,计算树脂去除总量和两组器械的中心定位力,同时记录和分析根管工作长度的变化和器械变形、分离等参数。结果:两种器械预备根管时,均能保持较好的工作长度,不易发生器械分离,能够较好的维持根管原始走形,但在根尖段,WaveOne预备后的根管较易发生偏移。结论:ProTaperNext与WaveOne相比,在预备重度弯曲根管时具有良好的根管成形能力

References

[1]  Kum KY, Spngberg L, Cha BY,et al . Shaping ability of three ProFile rotary instrumentation techniques in simulated resin root canals [J]. J Endod, 2000, 26(12)∶719-723
[2]  Yared G. Canal preparation using only one Ni-Ti rotary instrument: preliminary observations [J]. Int Endod J, 2008, 41(4)∶339-344
[3]  Elnaghy AM. Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files [J]. Int Endod J, 2014, 47(11)∶1034-1039
[4]  Wu H, Peng C, Bai Y,et al . Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals [J]. BMC Oral Health, 2015, 15(1)∶27-30
[5]  Yang GB, Zhou XD, Zhang H, et al . Shaping ability of progressive versus constant taper instruments in simulated root canals [J]. Int Endod J, 2006, 39(10)∶791-799
[6]  Schfer E, Florek H. Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals [J]. Int Endod J, 2003, 36(3)∶199-207
[7]  Burroughs JR, Bergeron BE, Roberts MD, et al. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals [J]. J Endod, 2012, 38(12)∶1618-1621
[8]  Shen Y, Cheung GS, Bian Z,et al. Comparison of defects in ProFile and ProTaper systems after clinical use [J]. J Endod, 2006, 32(1)∶61-65
[9]  Schneider SW. A comparison of canal preparations in straight and curved root canals [J]. Oral Surg Oral Med Oral Pathol, 1971, 32(2)∶271-275
[10]  Pruett JP, ClementDJ,CarnesDL Jr. Cyclic fatigue testing of nickel-titanium endodontic instruments [J]. J Endod, 1997, 23(2)∶77-85
[11]  Gergi R, Rjeily JA, Sader J, et al . Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography [J]. J Endod, 2010, 36(5)∶904-907
[12]  Tasdemir T, Aydemir H, Inan U, et al .Canal preparation with Hero 642 rotary Ni-Ti instruments compared with stainless steel hand K-file assessed using computed tomography [J]. Int Endod J, 2005, 38(6)∶402-408
[13]  杨国斌,郑玉露,许为群,等.机用PtoTaper锉和Flexofile不锈钢锉根管成形能力的对比研究[J].华西口腔医学杂志,2007,25(4)∶386-389

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133