Tuberculosis represents a main concern for public health worldwide. In poor countries, the most prevalent method for bacteriological confirmation re- mains Smear Sputum Microscopy (SSM). This study objective was to assess clinical performances of Loop Mediated Isothermal Amplification for TB detection (Lamp-TB). Sputum of patients presenting symptoms consistent with tuberculosis were collected according to the National Tuberculosis Control Programme guidelines in Centre Antituberculeux de Yopougon. SSM after Ziehl-Neelsen staining and TB-Lamp were blindly performed with spot sputum specimen. Samples, transported at Institut Pasteur de Cote d’Ivoire were decontaminated according to N-acetyl-L-cystein (NALC) method. In Mycobacteria Growth Indicator Tube (MGIT), 500 μl of pellet were inoculated and incubated in MGIT 960 instrument. MPT64 antigen was detected on positive culture. Of 500 patients enrolled, 469 were included. Clinical isolates of M. tuberculosis Complex were detected for 157 (33.5%). Comparatively to culture, Sensitivity and Specificity of SSM were 86% (95% Confidence interval (CI): 81% - 91%) 96% (95%IC: 94% - 98%) respectively. TB-Lamp Sensitivity was 92% (95%CI: 88% - 96%), and Specificity 94% (95%CI: 91% - 97%). Positive Predictive Value of SSM and TB-Lamp was 91.8% and 88.8% respectively. Negative Predictive Value of TB-Lamp assay was 95.7% whereas this of SSM was 93.3%. Positive Likelihood Ratio was 15.3 for TB-Lamp and 21.5 for SSM 21.5 whereas negative Likelihood of TB-Lamp was lower than SSM. Active tuberculosis was detected in162/469 (34.5%) with TB-Lamp and 147 (31.3%) with SSM. TB-Lamp assay performances estimated from sputum samples may improve detection of active TB cases in routine.
References
[1]
World Health Organization (2015) Global Tuberculosis Report 2015, WHO/HTM/ TB/2015. 22. World Health Organization, Geneva, Switzerland.
[2]
Somoskovi, A., Hotaling, J.E., Fitzgerald, M., O’Donnell, D., Parsons, L.M. and Salfinger, M. (2001) Lessons from a Proficiency Testing Event for Acid-Fast Micro- scopy. Chest, 120, 250-257. https://doi.org/10.1378/chest.120.1.250
[3]
Shea, Y.R., Davis, J.L., Huang, L., Kovacs, J.A., Masur, H., Mulindwa, F., Opus, S., Chow, Y. and Murray, P.R. (2009) High Sensitivity and Specificity of Acid-Fast Microscopy for Diagnosis of Pulmonary Tuberculosis in an African Population with a High Prevalence of Human Immunodeficiency Virus. Journal of Clinical Micro- biology, 47, 1553-1555. https://doi.org/10.1128/JCM.00348-09
[4]
Steingart, K.R., Ramsay, A. and Pai, M. (2007) Optimizing Sputum Smear Micro- scopy for the Diagnosis of Pulmonary Tuberculosis. Expert Review of Anti-Infective Therapy, 5, 327-331. https://doi.org/10.1586/14787210.5.3.327
[5]
Grosset, J. (1995) Place des examens microbiologiques et anatomopathologiques dans la décision diagnostique et thérapeutique. Médecine et Maladies Infectieuses, 25, 327-333. https://doi.org/10.1016/S0399-077X(05)80591-8
[6]
Boehme, C.C., Nabeta, P., Henostroza, G., Raqib, R., Rahim, Z., Gerhardt, M., Sanga, E., Hoelscher, M., Notomi, T., Hase, T. and Perkins, M.D. (2007) Operational Feasibility of Using Loop-Mediated Isothermal Amplification for Diagnosis of Pulmonary Tuberculosis in Microscopy Centers of Developing Countries. Journal of Clinical Microbiology, 45, 1936-1940. https://doi.org/10.1128/JCM.02352-06
[7]
World Health Organization (2013) Automated Real-Time Nucleic Acid Ampli- fication Technology for Rapid and Simultaneous Detection of Tuberculosis and Rifampicin Resistance: Xpert MTB/RIF Assay for the Diagnosis of Pulmonary and Extrapulmonary TB in Adults and Children. WHO/HTM/TB/2013.16, World Health Organization, Geneva, Switzerland.
[8]
Boehme, C.C., Nicol, M.P., Nabeta, P., Michael, J.S., Gotuzzo, E., Tahirli, R., Gler, M.T., Blakemore, R., Worodria, W., Gray, C., Huang, L., Caceres, T., Mehdiyev, R., Raymond, L., Whitelaw, A., Sagadevan, K., Alexander, H., Albert, H., Cobelens, F., Cox, H., Alland, D. and Perkins, M.D. (2011) Feasibility, Diagnostic Accuracy, and Effectiveness of Decentralised Use of the Xpert MTB/RIF Test for Diagnosis of Tuberculosis and Multidrug Resistance: A Multicentre Implementation Study. The Lancet, 377, 1495-1505. https://doi.org/10.1016/S0140-6736(11)60438-8
[9]
Notomi, T., Okayama, H., Masubuchi, H., Yonekawa, T., Watanabe, K. and Amino, N. (2000) Hase T: Loop-Mediated Isothermal Amplification of DNA. Nucleic Acids Research, 28, e63. https://doi.org/10.1093/nar/28.12.e63
[10]
Gray, C.M., Katamba, A., Narang, P., Giraldo, J., Zamudio, C., Joloba, M., Narang, R., Paramasivan, C.N., Hillemann, D., Nabeta, P., Amisano, D., Alland, D., Cobelens, F. and Boehme, C.C. (2016) Feasibility and Operational Performance of Tuberculosis Detection by Loop-Mediated Isothermal Amplification Platform in Decentralized Settings: Results from a Multicenter Study. Journal of Clinical Micro- biology, 54, 1984-1991. https://doi.org/10.1128/JCM.03036-15
[11]
Geojith, G., Dhanasekaran, S., Chandran, S.P. and Kenneth, J. (2011) Efficacy of Loop Mediated Isothermal Amplification (LAMP) Assay for the Laboratory Identi- fication of Mycobacterium tuberculosis Isolates in a Resource Limited setting. Journal of Microbiological Methods, 84, 71-73.
https://doi.org/10.1016/j.mimet.2010.10.015
[12]
Ou, X., Li, Q., Xia, H., Pang, Y., Wang, S., Zhao, B., Song, Y., Zhou, Y., Zheng, Y., Zhang, Z., Zhang, Z., Li, J., Dong, H., Zhang, J., Kam, K.M., Chi, J., Huan, S., Chin, D.P. and Zhao, Y. (2011) Diagnostic Accuracy of the PURE-LAMP Test for Pul- monary Tuberculosis at the County-Level Laboratory in China. PLoS ONE, 9, e94544.
[13]
Khatib, S.I., Williamson, M.T., Singh, R. and Joshi, J.M. (2012) Diagnosis of Pulmonary Tuberculosis by Smear Microscopy and Culture in a Tertiary Health Care Facility. Biology and Medicine, 4, 32-36.
[14]
Neonakis, I.K., Spandidos, D.A. and Petinaki, E. (2011) Use of Loop-Mediated Isothermal Amplification of DNA for the Rapid Detection of Mycobacterium tuberculosis in Clinical Specimens. European Journal of Clinical Microbiology & Infectious Diseases, 30, 937-942.
[15]
Mitarai, S., Okumura, M., Toyota, E., Yoshiyama, T., Aono, A., Sejimo, A., Azuma, Y., Sugahara, K., Nagasawa, T., Nagayama, N., Yamane, A., Yano, R., Kokuto, H., Morimoto, K., Ueyama, M., Kubota, M., Yi, R., Ogata, H., Kudoh, S. and Mori, T. (2011) Evaluation of a Simple Loop-Mediated Isothermal Amplification Test Kit for the Diagnosis of Tuberculosis. The International Journal of Tuberculosis and Lung Disease, 15, 1211-1217. https://doi.org/10.5588/ijtld.10.0629
[16]
World Health Organization (2016) The Use of Loop-Mediated Isothermal Ampli- fication (TB-LAMP) for the Diagnosis of Pulmonary Tuberculosis: Policy Guidance WHO/HTM/TB/2016.07. World Health Organization, Geneva, Switzerland.
[17]
Rahman, A., Sahrin, M., Afrin, S., Earley, K., Ahmed, S., Mazidur Rahman, S.M. and Banu, S. (2016) Comparison of Xpert MTB/RIF Assay and GenoType MTBDRplus DNA Probes for Detection of Mutations Associated with Rifampicin Resistance in Mycobacterium tuberculosis. PLoS ONE, 11, e0152694.
https://doi.org/10.1371/journal.pone.0152694
[18]
Bojang, A.L., Mendy, F.S., Tientcheu, L.D., Otu, J., Antonio, M., Kampmann, B., Agbla, S. and Sutherland, J.S. (2016) Comparison of TB-LAMP, GeneXpert MTB/ RIF and Culture for Diagnosis of Pulmonary Tuberculosis in the Gambia. Journal of Infection, 72, 332-337. https://doi.org/10.1016/j.jinf.2015.11.011
[19]
Mboowa, G., Namaganda, C. and Ssengooba, W. (2014) Rifampicin Resistance Mutations in the 81 bp RRDR of rpoB Gene in Mycobacterium tuberculosis Clinical Isolates Using Xpert?MTB/RIF in Kampala, Uganda: A Retrospective Study. BMC Infectious Diseases, 14, 481. https://doi.org/10.1186/1471-2334-14-481
[20]
Parsons, L.M., Somoskovi, A., Gutierrez, C., Lee, E., Paramasivan, C.N., Abimiku, A., Spector, S., Roscigno, G. and Nkengasong, J. (2011) Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries. Challenges and Opportunities. Clinical Microbiology Reviews, 24, 314-350. https://doi.org/10.1128/CMR.00059-10