受纳米结构损伤限制的光纤拉曼探头SERS探测灵敏度

, PP. 348-353

Keywords: 光谱学,表面增强拉曼散射,光纤拉曼探头,损伤,局域表面等离子振荡

Full-Text   Cite this paper   Add to My Lib

Abstract:

利用光线追迹法,研究了典型光纤拉曼探头在纳米结构损伤限制下收集到的SERS功率与样品位置之间关系,结果表明,对于不同焦距构成的同轴等光程光纤拉曼探头,在给定的纳米结构损伤阈值激发光功率密度下,样品偏离焦平面反而会使探头收集到的SERS功率增加,相比于样品远离探头方向偏离焦平面,靠近探头方向偏离焦平面时收集到的SERS功率更高。此外,收集光纤芯径越大,探头所收集的SERS功率越大。

References

[1]  Casiraghi C, Pisana S, Novoselov K. S, et al.. Raman Fingerprint of Charged Impurities in Graphene[J]. Appl. Phys. Lett., 2007, 91(3), 233108–233110. [2] Klimov E, Li W, Yang X, Hoffmann G G, et al.. Chemical Reaction Imaging within Microfluidic Devices Using Confocal Raman Spectroscopy: The Case of Water and Deuterium Oxide as a Model System[J]. Anal. Chem., 2008, 80(5): 1689–1695 [3] Fiedler A, Baranska M. and Schulz H. FT-Raman spectroscopy-a rapid and reliable quantification protocol for the determination of natural indigo dye in Polygonum tinctorium[J]. J. Raman Spectrosc., 2010, 42(2): 551–557 [4] Zhang Y Y, Zhang X F,Cao J, Mao Q H. Decanethiol-modified Au/Ag SERS substrates for detection of polychlorinated biphenyl-77[J]. Chinese Journal of Quantum Electronics (量子电子学报), 2012, 29(3): 357-361 (in Chinese) [5] Zheng R S, Lu Y H, et al. Recent progress of research on surface plasmon resonance sensors[J]. Chinese Journal of Quantum Electronics (量子电子学报), 2008, 25(6): 657-664 (in Chinese) [6] Samuel L K, Emilie R, Nicholas V, et al.. Single-Molecule Surface-Enhanced Raman Spectroscopy of Crystal Violet Isotopologues: Theory and Experiment[J]. J. Am. Chem. Soc., 2011, 133 (11):4115–4122 [7] Winterhalder M J, Zumbusch Lippitz A M, and Orrit M. Toward Far-field Vibrational Spectroscopy of Single Molecules at Room Temperature[J]. J. Phys. Chem. B, 2011, 115 (18):5425–5430 [8] John R L, and Ronald L B. Single Molecule SERS Spectral Blinking and Vibronic Coupling[J].J. Phys. Chem. C, 2011, 115 (11):4540–4545 [9] Paul I O, and Michael D M. Polymer-capped fiber-optic Raman probe for non-invasive Raman spectroscopy[J]. Analy., 2012,137(1):77-81 [10] Pentti N, Janne S. Rugged Fiber-Optic Raman Probe for Process Monitoring Applications [J]. Appl Spectrosc, 2001,55(2):1337-1340 [11] Nick G, Susan C, Steele D, and Jop J. Double-Ended Calibration of Fiber-Optic Raman Spectra Distributed Temperature Sensing Data [J]. Sens., 2012,12(5): 5471-5485 [12] Dejesu M A S, Giesfeldt K S, and M. J. Sepaniak. Use of a Sample Translation Technique to Minimize Adverse Effects of Laser Irradiation in Surface-Enhanced Raman Spectrometry[J]. Appl Spectrosc.,2003, 57(9): 428- 438 [13] Maier S A, Plasmonics: fundamentals and applications[B]. New York, Springer, 2006. [14] Baltog I, Primeau N, and Reinisch R. Surface enhanced Raman scattering on silver grating: Optimized antennalike gain of the stokes signal of 104[J]. Appl. Phys. Lett..1995,66(10):1187-1189

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133