全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
电网技术  2010 

开关设备中SF6气体分解产物检测的应用

, PP. 160-165

Full-Text   Cite this paper   Add to My Lib

Abstract:

运行经验表明,通过检测开关设备中SF6气体分解产物对设备内部绝缘进行故障诊断和状态评估,具有抗干扰能力强、灵敏度高等优势,被广泛用于设备现场检测分析。通过分析开关设备的SF6气体检测理论,在SF6气体分解产物检测技术的指导下,对运行中设备、故障设备和型式试验后设备的SF6气体分解产物进行检测和结果分析,确定了设备在不同状态下的SF6气体组分及其含量。基于大量设备的SF6气体分解产物现场检测结果,指出了SF6气体绝缘设备故障的特征气体及其在设备故障诊断中的应用前景。

References

[1]  Piemontesi M,Niemeyer L.Sorption of SF6 and SF6 decomposition products by activated alumina and molecular sieve 13X[C].IEEE International Symposium on Electrical Insulation,Montreal,Quebec,Canada,1996.
[2]  Suehiro J Y,Zhou G B,Hara M.Detection of partial discharge in SF6 gas using a carbon nanotube-based gas sensor[J].Sensors and Actuators,2005,105(2):164-169.
[3]  Beyer C,Jenett H,Klockow D.Influence of reactive SFX gases on electrode surfaces after electrical discharges under SF6 atmosphere [J].IEEE Trans on Dielectrics and Electrical Insulation,2000,7(2):234-240.
[4]  裘吟君,刘岩,陈晓琳,等.SF6气体杂质与潜伏性故障诊断技术研究[J].南方电网技术,2009(3):67-71.
[5]  Qiu Yinjun,Liu Yan,Chen Xiaolin,et al.Study on SF6 gas impurities and potential faults diagnosis[J].Southern Power System Technology,2009(3):67-71(in Chinese).
[6]  王小波,谢开贵.计及开关故障的复杂配电系统可靠性评估[J].电网技术,2008,32(19):16-21.
[7]  Wang Xiaobo,Xie Kaigui.Reliability evaluation of complex distribution system taking switch faults into account[J].Power System Technology,2008,32(19):16-21(in Chinese).
[8]  刘有为,吴立远,弓艳朋.GIS设备气体分解物及其影响因素研究[J].电网技术,2009,33(5):58-61.
[9]  Liu Youwei,Wu Liyuan,Gong Yanpeng.Investigation on SF6 decomposition products in GIS and affecting factors[J].Power System Technology,2009,33(5):58-61(in Chinese).
[10]  游荣文,黄逸松.基于SO2、H2S含量测试的SF6电气设备内部故障的诊断[J].福建电力与电工,2004(2):15-16,57.
[11]  You Rongwen,Huang Yisong.Diagnosis of internal faults in SF6 electrical equipments based on measuring SO2 and H2S[J].Fujian Electric and Electrician,2004(2):15-16,57(in Chinese).
[12]  姚唯建,钟志铿.气体分析法用于六氟化硫电气设备故障的检测[J].广东电力,1994(2):21-24.
[13]  Yao Weijian,Zhong Zhijian.Gas analysis method used to detect fault of SF6 electrical equipment[J].Guangdong Electric Power, 1994(2):21-24 (in Chinese).
[14]  庄贤盛,李智,姚唯建,等.SF6电气设备放电故障检测和判断方法[J].广东电力,2008,21(12):35-38,67.
[15]  Zhuang Xiansheng,Li Zhi,Yao Weijian,et al.Detection and judgment of discharge failures of sulphur hexanuoride electrical equipment[J].Guangdong Electric Power,2008,21(12):35-38,67(in Chinese).
[16]  黄云光,朱立平,王琪.气体分析在GIS闪络定位中的应用[J].广西电力技术,2000,23(4):33-35,53.
[17]  张仲旗,连鸿松.通过检测SO2发现SF6电气设备故障[J].中国电力,2001,34(1):78-81.
[18]  Zhang Zhongqi,Lian Hongsong.Using SO2 detection for failure checking of SF6 electrical equipment[J].Electric Power, 2001,34(1):78-81(in Chinese).
[19]  刘佳,朱华,仝松利,等.气体分析技术在SF6设备内部故障判断中的应用[J].河南电力,2009(1):32-34,44.
[20]  Liu Jia,Zhu Hua,Tong Songli,et al.The application of gas analysis technique on line fault judgment of SF6 equipments[J].Henan Electric Power,2009(1):32-34,44(in Chinese).
[21]  蔡巍,黄韬颖,李帆.动态离子分析在SF6电气绝缘设备诊断中的应用[J].华北电力技术,2006(1):31-33, 41.
[22]  Cai Wei,Huang Taoying,Li Fan.Application of ion mobility spectrometry technique in diagnosis of gas condition in SF6 electric insulating equipment[J].North China Electric Power, 2006(1):31-33,41(in Chinese).
[23]  毕玉修,卞超.应用SF6气体分解物进行电气设备故障诊断的探讨[J].江苏电机工程,2007,26(5):14-17.
[24]  Bi Yuxiu,Bian Chao.Research on electric equipment fault diagnosis applied on SF6 decomposing gases[J].Jiangsu Electrical Engineering,2007,26(5):14-17(in Chinese).
[25]  罗学琛.SF6气体绝缘全封闭组合电器(GIS)[M]. 北京:中国电力出版社,1998:13-26.
[26]  中华人民共和国电力工业部.DL/T 596—1996 电力设备预防性试验规程[S].北京:中国电力出版社,1997.
[27]  罗志,王杰.高压开关机械故障诊断平台开发[J].电网技术,2007, 31(增刊1):134-136.
[28]  Luo Zhi,Wang Jie.Development of mechanical fault analysis and diagnosis platform for HV circuit breaker[J].Power System Technology,2007,31(Supplement 1):134-136(in Chinese).
[29]  丁繁荣,赵学军,张敏强.高压电气设备SF6气体危害及防范措施[J].电网技术,2007 ,31(增刊2):26-29.
[30]  Ding Fanrong,Zhao Xuejun,Zhang Minqiang.Hazards of SF6 gas in power equipment on human and environment and preventive measures[J].Power System Technology,2007 ,31(Supplement 2):26-29 (in Chinese).
[31]  Huang Yunguang,Zhu Liping,Wang Qi.Application in locating GIS discharge by gas analysis[J].Guangxi Electrical Power Technology, 2000,23(4):33-35,53(in Chinese).
[32]  汪金星,杨韧,郑小川.SF6开关设备带电测试新技术在陕西电网的应用[J].陕西电力,2008,36(11):15-17.
[33]  Wang Jinxing,Yang Ren,Zheng Xiaochuan.Application of novel live test methods for SF6 switch equipment to Shaanxi Power Grid [J].Shaanxi Electric Power,2008,36(11):15-17(in Chinese).
[34]  袁亮.高压电器中SF6气体分解物的检测与研究[D].长春:长春理工大学,2009.
[35]  秦澍麟.六氟化硫绝缘的高压电器译文[M].北京:中国电力科学研究院,2008:1-11.
[36]  中国电力科学研究院.GB/T 8905—1996 六氟化硫电气设备中气体管理和检测导则[S].北京:中国标准出版社,1997.
[37]  IEC.IEC 60480—2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrica1 equipment and specification for its re-use[S].Geneva:IEC,2004.
[38]  郭媛媛,刘汉梅,王承玉.SF6高压开关设备运行状态与气体成分关系的研究[R].北京:中国电力科学研究院,2007.