黄廷政, 莫娟, 彭宗仁, 等。高海拔地区330 kV线路用FD型防振锤防晕性能优化[J].电网技术, 2012, 36(6):262-265.Huang Tingzheng, Mo Juan, Peng Zongren, et al.Optimization of anti-corona performance of FD-type damper for 330kV transmission lines in high altitude localities[J].Power System Technology, 2012, 36(6):262-265(in Chinese).
[2]
DL/T 1178—2012 1 000 kV交流输电线路金具电晕及无线电干扰试验方法[S].
[3]
GB 311.1—2012 绝缘配合第1部分:定义、原则和规则[S].
[4]
汪泉弟, 褚旭, 杨帆, 等.500 kV同塔双回紧凑型输电线路输电能力分析[J].电网技术, 2011, 35(11):114-119.Wang Quandi, Chu Xu, Yang Fan, et al.Analysis on transmission capability of 500 kV double circuits on the same tower compact transmission lines[J].Power System Technology, 2011, 35(11):114-119(in Chinese).
[5]
龚有军, 朱普轩, 曾嵘.750 kV同塔同窗同相序紧凑型输电技术的可行性研究[J].电网技术, 2008, 32(13):50-54.Gong Youjun, Zhu Puxuan, Zeng Rong.Feasibility study of two compact 750 kV circuits with same phase sequence in the same tower window[J].Power System Technology, 2008, 32(13):50-54(in Chinese).
[6]
霍锋, 万启发, 谷定燮, 等.1 000 kV与500 kV交流线路同塔架设相间放电特性及绝缘配合[J].中国电机工程学报, 2012, 32(34):142-150.Huo Feng, Wan Qifa, Gudingxie, et al.Flashover characteristics and insulation coordination of phase-to-phase air-gaps for AC transmission line with 1 000 kV double-circuit and 500 kV double-circuit on the same tower[J].Proceedings of the CSEE, 2012, 32(34):142-150(in Chinese).
[7]
焦保利, 霍锋, 陈勇, 等.特高压同塔双回交流线路的外绝缘特性[J].高电压技术, 2009, 35(7):1526-1532.Jiao Baoli, Huo Feng, Chen Yong, et al.External insulation characteristic for UHV AC transmission line with double-circuit on the same tower[J].High Voltage Engineering, 2009, 35(7):1526-1532(in Chinese).
[8]
曹晶, 张勤, 杨迎建, 等.高海拔交流输电线路金具电晕放电特性[J].高电压技术, 2011, 37(12):2924-2929.Cao Jing, Zhang Qin, Yang Yingjian, et al.Corona discharge characteristic for fittings of high altitude AC transmission line[J].High Voltage Engineering, 2011, 37(12):2924-2929(in Chinese).
[9]
谷琛, 范建斌, 殷禹, 等.±1 000 kV特高压直流输电系统设备电晕特性[J].高电压技术, 2012, 38(12):3182-3188.Gu Chen, Fan Jianbin, Yin Yu, et al.Corona characteristic of power equipments used in ±1 000 kV UHV DC system[J].High Voltage Engineering, 2012, 38(12):3182-3188.
[10]
曾庆禹.特高压输电线路电气和电晕特性研究[J].电网技术, 2007, 31(19):1-8.Zeng Qingyu.Study on electric characteristic and corona performance of UHV AC transmission line[J].Power System Technology, 2007, 31(19):1-8(in Chinese).
[11]
陈勇, 万启发, 谢梁, 等.1 000 kV交流输电线路导线的电晕特性[J].高电压技术, 2007, 33(11):43-45.Chen Yong, Wan Qifa, Xie Liang, et al.Corona characteristics of conductors for 1 000 kV AC transmission lines[J].High Voltage Engineering, 2007, 33(11):43-45(in Chinese).
[12]
谢梁, 谷莉莉, 郑怀清, 等.特高压交流刚性跳线金具电晕试验[J].高电压技术, 2009, 35(3):470-474.Xie Liang, Gu Lili, Zheng Huaiqing, et al.Corona test for UHVAC rigid jumper[J].High Voltage Engineering, 2009, 35(3):470-474(in Chinese).
[13]
陈建忠, 李勇伟, 张小力.750 kV输电线路耐张塔刚性跳线的研究开发[J].电力建设, 2006, 27(10):19-22.Chen Jianzhong, Li Yongwei, Zhang Xiaoli.Development of rigid jumper for strained towers of 750 kV transmission line[J].Electric Power Construction, 2006, 27(10):19-22(in Chinese).
[14]
李靖, 彭宗仁, 刘鹏, 等.特高压交流铝管式刚性跳线电场计算和分析[J].高电压技术, 2010, 36(1):205-211.Li Jing, Peng Zongren, Liu Peng, et al.Electric field calculation and analysis of UHVAC aluminum tube rigid jumper[J].High Voltage Engineering, 2010, 36(1):205-211(in Chinese).
[15]
李显鑫, 石改萍.单柱组合耐张塔跳线设计及计算[J].电力技术, 2010, 19(5):47-50.Li Xianxin, Shi Gaiping.Design and calculation of the jumper of single-pole-combined strain tower[J].Electric Power Technology, 2010, 19(5):47-50(in Chinese).
[16]
胡毅, 刘凯, 王力农, 等.1 000 kV同塔双回输电线路带电作业技术试验研究[J].高电压技术, 2010, 36(11):2668-2673.Hu Yi, Liu Kai, Wang Linong, et al.Experimental research of live working on 1000kV double circuit ac transmission line on the same tower[J].Electric Power Technology, 2010, 36(11):2668-2673(in Chinese).
[17]
IEC61284—1997 Overhead lines-Requirements and tests for fittings[S].