首先提出采用铁道统一电能质量控制器(railwayunifiedpowerqualitycontroller,RUPQC)实现牵引变电站综合补偿的充要条件;然后在建立牵引负荷标幺化模型的基础上,分别以实现完全补偿和灵活补偿为目标,提出了结合固定补偿装置的RUPQC容量综合配置方法。数值分析表明,采用该配置方法并结合灵活最优控制策略,RUPQC可在全负荷范围内满足灵活补偿的目标,不但显著降低了装置的工程造价,而且在任意负荷条件下均能实现对装置补偿容量的最优利用。

References

[1]  任震,余得伟,唐卓尧.基于模糊优化设计的混合滤波器:治理电气化铁道谐波的一种新方法[J].中国电机工程学报,2001,21(2):66-68.
[2]  Ren Zhen,Yu Dewei,Tang Zhuoyao.A new method for eliminating harmonics of electrified railway with hybrid filter based on the fuzzy optimizing design[J].Proceedings of the CSEE,2001,21(2):66-68(in Chinese).
[3]  Fujii K,Kunomura K,Yoshida K,et al.STATCOM applying flat-packaged IGBTs connected in series[J].IEEE Trans on Power Electronics,2005,20(5):233-238.
[4]  唐敏,李群湛,贺建闽.牵引变电所无功谐波综合补偿方案研究[J].电网技术,2004,28(2):47-52.
[5]  Tang Min,Li Qunzhan,He Jianmin.Structure of hybrid power filter for reactive power and harmonic currents in substation[J].Power System Technology,2004,28(2):47-52(in Chinese).
[6]  Uzuka T,Ikedo S,Ueda K.A static voltage fluctuation compensator for AC electric railway[C].IEEE Power Electronics Specialists Conference,Aachen,Germany,2004.
[7]  兎束哲夫,池戸昭治,上田啓二,等.新幹線用電圧変動補償装置の開発と実用化[J].電気学会論文誌B (電力?エネルギー部門誌),2005,125(9):885-892.
[8]  電気学会.電気学会技術報告第979号:铁道にぉけるパヮ-ェレクトロニス技术[R].日本,东京:電気学会,2006.
[9]  魏光,李群湛,黄军,等.新型同相牵引供电系统方案[J].电力系统自动化,2008,32(10):80-83.
[10]  Wei Guang,Li Qunzhan,Huang Jun,et al.A new cophase traction power supply system[J].Automation of Electric Power Systems,2008,32(10):80-83(in Chinese).
[11]  Senini S T,Wolfs P J.Novel topology for correction of unbalanced load in single phase electric traction systems[C].IEEE Power Electronics Specialists Conference,Cairns,Queensland,Australia,2002.
[12]  张秀峰,李群湛,吕晓琴.基于有源滤波器的V,v接同相供电系统[J].中国铁道科学,2006,27(2):98-103.
[13]  Zhang Xiufeng,Li Qunzhan,Lü Xiaoqin.V,v connection cophase power supply system based on active power filter[J].China Railway Science,2006,27(2):98-103(in Chinese).
[14]  Wan Qingzhu,Zhu Guiping,Chen Jianye,et al.Optimum design of compensation capacity for balancing the single-phase traction load[J].Automation of Electric Power Systems,2008,32(8):93-97(in Chinese).
[15]  Wei Yingdong,Jiang Qirong,Zhang Xiujuan.A novel control strategy for optimization of power capacity based on railway power static conditioner[C].IEEE Applied Power Electronics Conference and Exposition,Austin,Texas,2008.
[16]  张丽艳,李群湛,徐英雷.牵引变电站无功与负序分量的综合补偿[J].电网技术,2008,32(21):17-21.
[17]  魏应冬,姜齐荣,韩英铎,等.基于负序与无功对称解耦的RUPQC最优补偿策略[J].电力系统自动化,2009,33(16):55-60.
[18]  Wei Yingdong,Jiang Qirong,Han Yingduo,et al.Optimal compensation strategy of RUPQC based on reactive power and negative sequence components symmetrical decoupling[J].Automation of Electric Power Systems,2009,33(16):55-60(in Chinese).
[19]  Ribeiro P F.An overview of power quality problems in transportation and isolated power systems[C].IEEE Power Engineering Society Summer Meeting,Vancouver,BC,2001.
[20]  张小瑜,吴俊勇.电气化铁路接入电力系统的电压等级问题[J].电网技术,2007,31(7):12-17.
[21]  Zhang Xiaoyu,Wu Junyong.Research on voltage class of power system to be connected with electrified railways[J].Power System Technology,2007,31(7):12-17(in Chinese).
[22]  姚宗溥,侯世英,祝石厚.电气化铁路牵引负荷对固原电网的影响[J].电网技术,2007,31(1):15-19.
[23]  Yao Zongpu,Hou Shiying,Zhu Shihou.Influence of electrical railway’s traction load on Guyuan power network[J].Power System Technology,2007,31(1):15-19(in Chinese).
[24]  姚金雄,张涛,林榕,等.牵引供电系统负序电流和谐波对电力系统的影响及其补偿措施[J].电网技术,2008,32(9):61-64.
[25]  Yao Jinxiong,Zhang Tao,Lin Rong,et al.Impacts of negative sequence current and harmonics in traction power supply system for electrified railway on power system and compensation measures[J].Power System Technology,2008,32(9):61-64(in Chinese).
[26]  苏玉香,刘志刚,李科亮,等.Hilbert-Huang变换在电气化铁路谐波检测中的应用[J].电网技术,2008,32(18):30-35.
[27]  Su Yuxiang,Liu Zhigang,Li Keliang,et al.Application of Hilbert-Huang transform in harmonic detection of electrified railway[J].Power System Technology,2008,32(18):30-35(in Chinese).
[28]  周胜军,于坤山,冯满盈,等.电气化铁路供电电能质量测试主要结果分析[J].电网技术,2009,33(13):54-57,63.
[29]  Zhou Shengjun,Yu Kunshan,Feng Manying,et al.Analysis on main results of power quality test of power supply for electrified railway[J].Power System Technology,2009,33(13):54-57,63(in Chinese).
[30]  张秀峰,连级三,高仕斌.基于三相变四相变压器的新型同相牵引供电系统[J].中国电机工程学报,2006,26(15):19-23.
[31]  Zhang Xiufeng,Lian Jisan,Gao Shibin.A new cophase traction power supply system based on three-phase to four-phase transformer[J].Proceedings of the CSEE,2006,26(15):19-23(in Chinese).
[32]  Griinbaum R,Hasler J P,Thorvaldsson B.FACTS: powerful means for dynamic load balancing and voltage support of AC traction feeders[C].IEEE Porto Power Tech Conference,Porto,2001.
[33]  王跃,杨君,王兆安,等.电气化铁路用混合电力滤波器的研究[J].中国电机工程学报,2003,23(7):23-27.
[34]  Wang Yue,Yang Jun,Wang Zhaoan,et al.Study on hybrid power filter used in electrified railway system[J].Proceedings of the CSEE,2003,23(7):23-27(in Chinese).
[35]  赵伟,涂春鸣,罗安,等.适用于电气化铁路的单相注入式混合有源滤波器[J].中国电机工程学报,2008,28(21):51-56.
[36]  Zhao Wei,Tu Chunming,Luo An,et al.A novel single-phase hybrid active power filter applied to electrical railway system[J].Proceedings of the CSEE,2008,28(21):51-56(in Chinese).
[37]  万庆祝,朱桂萍,陈建业,等.平衡单相牵引负荷补偿容量优化设计[J].电力系统自动化,2008,32(8):93-97.
[38]  Zhang Liyan,Li Qunzhan,Xu Yinglei.Comprehensive compensation of reactive power and negative sequence components for traction substations[J].Power System Technology,2008,32(21):17-21(in Chinese).

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133