Grandl J,Eriksson A,Meppelink J.Studies of very fast transient(VFT) in a 765 kV substation[R].Paris:CIGRE,1988.
[2]
Lewis J,Pryor B M,Jones C J,et al.Disconnector operations in gas insulated substations over voltage studies and tests associated with a 420 kV installation[C]//CIGRE Conference.Paris,France:CIGRE,1988.
Chen Weijiang,Yan Xianglian,Wang Shaowu,et al.Recent progress in investigations on very fast transient overvoltage in gas insulated switchgear[J].Proceedings of the CSEE,2011,31(31):1-11(in Chinese).
[5]
何善庆.GIS中的快速暂态现象[J].高压电器,1995, 31(2):41-46.
[6]
He Shanqing.Fast transient phenomenon in GIS[J].High Voltage Apparatus,1995,31(2):41-46(in Chinese).
Ruan Quanrong,Shi Wei,Wang Liang.Study on suppression of switching overvoltage caused by operation of disconnector in GIS[J].High Voltage Apparatus,2006,42(1):18-20(in Chinese).
[9]
Working Group 33/13-09.Very fast transient phenomenon associated with gas insulated substations[C]//CIGRE Conference.Paris,France:CIGRE,1988.
[10]
Meppelink J,Diederich K J,Feser K,et al.Very fast transients in GIS[J].IEEE Trans on Power Delivery,1989,4(1):223-233.
[11]
Povh D,Schmitt H,Volcker O,et al.Modeling and analysis guidelines for very fast transients[J].IEEE Power Engineering Review,1996,17(13):71.
Yang Aimin,Gao Shuguo,Zhang Zhongyuan,et al.Modeling and calculation of the wave process in transformer windings under VFTO[J].High Voltage Engineering,2007,33(5):22-24(in Chinese).
Shao Tao,Yuan Weiqun,Sun Guangsheng,et al.Experimental study of repetitively nanosecond-pulse breakdown in atmospheric air[J].Proceedings of the CSEE,2005,25(8):161-166(in Chinese).
[16]
Srivastava K D,Zhou J.Surface charging and flashover of spacers in SF6 under impulse voltages[J].IEEE Trans on Electrical Insulation,1991,26(3):428-442.
[17]
Luxa G,Kynast E,Boeck W,et al.Recent research activity on the dielectric performance of SF6 with special reference to very fast transients[C]//CIGRE Conference ,Paris,France:CIGRE,1988.
Ran Huijuan,Wang Jue,Wang Tao,et al.Breakdown characteristics in compressed SF 6 under nanosecond-pulses[J].High Voltage Engineering,2012,38(7):1690-1696 (in Chinese).
Liu Weidong,Wang Linsen,Chen Weijiang,et al.Investigation of the VFTO related repeated breakdown processes in UHV GIS[J].High Voltage Engineering,2011,37(3):644-650(in Chinese).
Han Bin,Lin Jiming,Chen Weijiang,et al.Analysis on the influence of the switching speed of disconnector on very fast transient overvoltage[J].Proceedings of the CSEE,2011,31(31):12-16(in Chinese).
[24]
IEC 60129—1984 Alternating current disconnectors and earthing switches[S].Switzerland: International Electrotechnical Commission,1984.
Zhan Huamao,Zhao Chengnan,Duan Shaofeng,et al.Measuring of very fast transient over-voltage and very fast transient current generated by disconnector in gas insulated switchgear switching on/off short buses with no load[J].High Voltage Engineering,2013,39(6):1317-1323(in Chinese).
Wu Hao,Li Chengrong,Xu Hairui,et al.Method for measurement of VFTO based on GIS disk sensor[J].Transactions of China Electrotechnical Society,2012,27(9):210-217(in Chinese).
[29]
Rao M M,Jain H S,Rengarajan S,et al.Measurement of very fast transient overvoltages (VFTO) in a GIS module[C]//Eleventh International Symposium on High Voltage Engineering,London,UK:[s.n.],1999:144-147.