电网技术  2014 

±800kV直流线路故障过程中电磁耦合特性与保护研究

DOI: 10.13335/j.1000-3673.pst.2014.08.018, PP. 2133-2140

Keywords: 电磁耦合,特高压直流输电,故障过电压,雷电故障,接地故障,线路保护

Full-Text   Cite this paper   Add to My Lib

Abstract:

为提高直流输电系统运行的可靠性,实现直流线路保护的有效动作,避免误动,必须对直流输电系统的电磁耦合特性进行研究。以云广特高压直流输电工程为研究对象,并参照其线路参数,建立了包含杆塔、输电线路、避雷器、绝

References

[1]  赵畹君.高压直流输电工程技术[M].北京:中国电力出版社,2004:213-215,261-278.
[2]  吴驰,张龙伟,朱军,等.共走廊同塔交直流输电线路电磁耦合分量的计算分析[J].中国电力,2013,46(4):43-47.
[3]  Wu Chi,Zhang Longwei,Zhu Jun,et al.Calculation and analysis on electromagnetic coupling component of AC/DC transmission lines on the same tower built in same corridor[J].Electric Power,2013,46(4):43-47(in Chinese).
[4]  任姝,何为,杨帆,等.同塔交直流线路容性耦合干扰的分析与计算[J].高压电器,2012,48(4):39-45.
[5]  Ren Shu,He Wei,Yang Fan,et al.Analysis and calculation for the capacitive coupling of the AC and DC transmission lines on one tower[J].High-Voltage Apparatus,2012,48(4):39-45(in Chinese).
[6]  普子恒,阮江军,杜志叶,等.同塔双回500 kV高压直流线路感应过电压研究[J].高压电器,2012,48(10):52-57.
[7]  Pu Ziheng,Ruan Jiangjun,Du Zhiye,et al.Investigation to over-voltage on 500 kV HVDC double-circuit lines on same tower5 [J].High-voltage Apparatus,2012,48(10):52-57 (in Chinese) .
[8]  李新年,吕鹏飞,杨鹏,等.同塔架设直流线路的相互影响研究[J].电网技术,2012,36(11):222-228.
[9]  Li Xinnian,Lü Pengfei,Yang Peng,et al.Inter-influences between HVDC transmission lines erected on same tower[J].Power System Technology,2012,36(11):222-228(in Chinese).
[10]  张民,石岩.同杆并架±500 kV直流系统间相互影响的实时仿真分析[J].电网技术,2007,31(1):44-49.
[11]  Zhang Min,Shi Yan.Real-time digital simulation analysis on interaction between two ±500 kV HVDC systems erected on the same tower[J].Power System Technology,2007,31(1):44-49(in Chinese).
[12]  石岩,王庆,聂定珍,等.500 kV直流输电工程同杆并架技术的综合研究[J].电网技术,2006,30(21):1-6.
[13]  Shi Yan,Wang Qing,Nie Dingzhen,et al.Comprehensive study on technology of two bipole lines on the same tower for ±500 kV HVDC project[J].Power System Technology,2006,30(21):1-6(in Chinese).
[14]  隋国平.云广特高压直流输电线路双极闭锁时安稳装置的动作分析[J].高电压技术,2012,38(2):421-426.
[15]  Sui Guoping.Power safe system analysis of ±800 kV Yun-Guang UHVDC when bipole blocking[J].High Voltage Engineering,2012,38(2):421-426(in Chinese).
[16]  李立浧,司马文霞,杨庆,等.云广±800 kV 特高压直流输电线路耐雷性能研究[J].电网技术,2007,31(8):1-5.
[17]  Li Licheng,Sima Wenxia,Yang Qing,et al.Research on lightning withstand performance of ±800 kV ultra HVDC power transmission line from Yunnan to Guangdong[J].Power System Technology,2007,31(8):1-5(in Chinese).
[18]  Rizk F A M.A model for switching impulse leader inception and breakdown of long air-gaps[J].IEEE Trans on Power Delivery,1989,4(1):596-606.
[19]  杨庆,赵杰,司马文霞,等.云广特高压直流输电线路反击耐雷性能[J].高电压技术,2008,34(7):1330-1335.
[20]  Yang Qing,Zhao Jie,Sima Wenxia,et al.Lightning back-flashover performance of the Yun-Guang UHVDC transmission lines[J].High Voltage Engineering,2008,34(7):1330-1335(in Chinese).
[21]  冯鸫,罗海志,杨洁民,等.高压直流输电系统接地极过压保护机理及改进措施研究[J].高压电器,2011,47(12):49-55.
[22]  Feng Dong,Luo Haizhi,Yang Jiemin,et al.Principle and improvement of the earth electrode overvoltage protection for an HVDC project[J].High-Voltage Apparatus,2011,47(12):49-55(in Chinese).
[23]  束洪春,王永治,程春和,等.±800 kV直流输电线路雷击电磁暂态分析与故障识别[J].中国电机工程学报,2008,28(19):93-100.
[24]  Shu Hongchun,Wang Yongzhi,Cheng Chunhe,et al.Analysis of electromagnetic transient and fault detection on ±800 kV UHVDC transmission lines under lightning stroke[J].Proceedings of the CSEE,2008,28(19):93-100(in Chinese).
[25]  陈明,相艳会,郭倩雯,等.天广±500 kV高压直流输电系统建模及仿真[J].中国电力,2013,46(6):30-33.
[26]  Chen Ming,Xiang Yanhui,Guo Qianyun,et al.Modeling and simulation of Tianshengqiao-Guangdong ±500 kV HVDC transmission system[J].Electric Power,2013,46(6):30-33(in Chinese).
[27]  刘洪涛,李建设,苏寅生,等.云广±800kV 直流输电工程控制系统的特点[J].南方电网技术,2010,4(2):35-38.
[28]  Liu Hongtao,Li Jianshe,Su Yinsheng,et al.Characteristics of Yunnan-Guangdong ±800 kV DC transmission project control system[J].Southern Power System Technology,2010,4(2):35-38(in Chinese).
[29]  刘可真,束洪春,孙士云,等.±800 kV云广特高压直流控制方式的动态特性分析[J].高电压技术,2010,36(1):190-195.
[30]  Liu Kezhen,Shu Hongchun,Sun Shiyun,et al.Analysis on dynamic characteristic of control mode for ±800 kV Yun-Guang UHVDC[J].High Voltage Engineering,2010,36(1):190-195(in Chinese).
[31]  刘莉,蔡永梁,张楠,等.云广特高压与贵广直流工程直流保护系统的异同点[J].中国电力,2010,43(8):82-86.
[32]  Liu Li,Cai Yongliang,Zhang Nan,et al.Similarities and differences between Yun-Guang UHVDC project and Gui-Guang HVDC project[J].Electric Power,2010,43(8):82-86(in Chinese).