穆子龙,李兴源,刘一民,等. 电力系统相邻两节点同时等值的方法研究[J]. 电力系统保护与控制,2012,40(20):32-37. MU Zilong,LI Xingyuan,LIU Yimin,et al. A simultaneous equivalent method for two adjacent nodes in power grid[J]. Power System Protection and Control,2012,40(20):32-37.
[2]
束 娜,周志勇,李艳丽. 直流换流站与交流变电站合建站站用电设计方案[J]. 现代电力,2011,28(6):29-33. SHU Na,ZHOU Zhiyong,LI Yanli. Study on the designing scheme for auxiliary power system project of combined DC converter and AC substation[J]. Modern Electric Power,2011,28(6):29-33.
[3]
朱岸明,王 森,胡攀峰,等. 德宝直流输电对750 kV宝鸡主变压器运行影响研究[J]. 电网与清洁能源,2010,26(12):67-70. ZHU Anming,WANG Sen,HU Panfeng,et al. Influences of the Deyang-Baoji DC Transmission line on the 750 kV power transformer in Baoji Power Substation[J]. Power System and Clean Energy,2010,26(12):67-70.
[4]
苑 舜,王天施. 电力变压器直流偏磁研究综述[J]. 高压电器,2010,46(3):83-87. YUAN Shun,WANG Tianshi. Summary of the research on transformer DC magnetic bias[J]. High Voltage Apparatus,2010,46(3):83-87.
[5]
皇甫成,阮江军,张 宇,等. 变压器直流偏磁的仿真研究及限制措施[J]. 高电压技术,2006,32(9):117-121. HUANGFU Cheng,RUAN Jiangjun,ZHANG Yu,et al. DC magnetic bias induced current effects on transformer and restricting methods[J]. High Voltage Engineering,2006,32(9):117-121.
[6]
赵畹君. 高压直流输电工程技术[M]. 北京:中国电力出版社,2004.
[7]
任志超,续建国,张一坤,等. 交直流互联系统直流地表电位简易算式[J]. 电工技术学报,2011,26(7):256-263. REN Zhichao,XU Jianguo,ZHANG Yikun,et al. Study of the simple formula of DC surface potential in AC-DC interconnected large power system[J]. Transactions of China Electrotechnical Society,2011,26(7):256-263.
[8]
吴 超,吴广宁,范建斌,等. 高压互联电网极址土层参数对直流地表电位影响的研究[J]. 高压电器,2011,47(3):41-46. WU Chao,WU Guangning,FAN Jianbin,et al. Influences of grounding site soil parameters on earth surface potential of the high-voltage interconnected power grid[J]. High Voltage Apparatus,2007,47(3):41-46.
曾麟钧,林湘宁,黄景光,等. 特高压自耦变压器的建模和电磁暂态仿真[J]. 中国电机工程学报,2010,30(1):91-97. ZENG Linjun,LIN Xiangning,HUANG Jingguang,et al. Modeling and electromagnetic transient simulation of UHV autotransformer[J]. Proceedings of the CSEE,2010,30(1):91-97.
[11]
LI Xiaoping,WEN Xishan,MARKHAM P N,et al. Analysis of nonlinear characteristics for a three-phase, five-limb transformer under DC bias[J]. IEEE Transactions on Power Delivery,2010,25(4):2504-2510.
[12]
ENRIGHT W, NAYAKO, WATSON. Three phase five-limb unified magnetic equivalent circuit transformer models for PSCAD V3[C]//Proc. Int. Conf. Power Syst. Transients.Budapest:[s.n.],1999:462-467.
[13]
李占元,赵 伟,丁 健,等. 国华台山发电厂主变直流偏磁问题分析与治理[J]. 电网技术,2009,33(6):33-38. LI Zhanyuan,ZHAO Wei,DING Jian,et al. Analysis and reformation on DC bias in main transformer of Guohua taishan Power Plant[J]. Power System Technology,2009,33(6):33-38.
[14]
马为民. 换流变压器中直流偏磁电流的计算[J]. 高电压技术,2004,30(11):48-49. MA Weimin. DC Biasing current in converter transformer[J]. High Voltage Engineering,2004,30(11):48-49.
[15]
张雪松,黄 莉. 基于PSCAD/EMTDC的变压器直流偏磁仿真研究[J]. 电力系统保护与控制,2012,40(19):78-84. ZHANG Xuesong,HUANG Li. Simulation analysis of DC magnetic bias induced current of transformer based on PSCAD/EMTDC[J]. Power System Protection and Control,2012,40(19): 78-84.