客运专线牵引网雷击率的计算

, PP. 79-84

Keywords: 电气几何模型,先导随机取向角,雷击距系数雷击率

Full-Text   Cite this paper   Add to My Lib

Abstract:

介绍了一种牵引网悬挂导线雷击率的算法,该算法用取向角概率密度函数来考虑下行先导发展路径的随机性特征,并计算了取向角上、下限函数。根据雷电流的概率密度函数在悬挂导线受雷曲面上积分确定等值受雷面积,再由等值受雷面积和地面落雷密度确定雷击率。基于该算法,在MATLAB中进行了编程计算并应用到一个实例。此外,还分析了导线高度和雷击距系数对雷击率的影响,并将本文计算结果与先前报道计算结果作了对比。结果表明,在考虑导线高度和雷击距系数影响后计算结果与先前报道结果相比差别较大。

References

[1]  郭小霞,樊春雷. 高速铁路雷击跳闸率的研究[J]. 电气化铁道,2011,22(6):29-31. GUO Xiao-xia,FAN Chun-lei. The Research of high-speed railway lightning trip-out rate[J]. Electric Railway, 2011,22(6):29-31.
[2]  李晓岚,尹小根,何俊佳,等. 基于改进电气几何模型的绕击跳闸率的计算[J]. 高电压技术,2006,32(3):42-44. LI Xiao-lan,YIN Xiao-gen,HE Jun-jia,et al. Calculation of shielding failure flashover rate for transmission line based on revised EGM[J]. High Voltage Engineering,2006,32(3):42-44.
[3]  WANG Xi,HE Jin-liang,PENG Xiang-yang,et al. Comparison of numerical analysis models for shielding failure of transmission lines[C]. 7th Asia-Pacific International Conference on Lightning,2011:376-380.
[4]  RIZK F. Modeling of transmission line exposure to direct lightning strokes[J]. IEEE Trans. Power Del,1990,5(4): 1983-1997.
[5]  ERIKSSON A J. An improved electro-geometric model for transmission line shielding analysis[J]. IEEE Trans on Power Delivery,1987,2(3):859-870.
[6]  WANG Xi,YU Zhan-qing,PENG Xiang-yang,et al. Comparison of numerical analysis models for shielding failure of transmission lines[J]. Elsevier-Electric Power Systems Research,2012(3):35-37.
[7]  LIU J. LIU M G. Improved electro-geometric model for estimating lightning outage rate of catenary[J]. IET Electrical Systems in Transportation.,2012 (1):1-8.
[8]  赵斌财,周浩,钟一俊. 输电线路雷电绕击研究方法浅议[J]. 电瓷避雷器,2008(1):29-34. ZHAO Bin-cai,ZHOU Hao,ZHONG Yi-jun. Approaching to rotated lightning strike on transmission line[J]. Insulators and Surge Arresters,2008(1):29-34.
[9]  谢广润. 电力系统过电压[M]. 武汉:水利电力出版社,1983.
[10]  SZCZERBINSKI M. A discussion of Faraday cage lightning protection and application to real building structures[J]. Journal of Electrostatics,2000,48(2):145-154.
[11]  李瑞芳,吴广宁,曹晓斌,等. 考虑雷电入射角后电气几何模型的改进[J]. 电瓷避雷器,2009(4):23-26. LI Rui-fang,WU Guang-ning,CAO Xiao-bin. Improvement of electro-geometric model with considering lightning strike angle[J]. Insulators and Surge Arresters,2009(4):23-26.
[12]  何金良,姜舟. 避雷器耐受输电线路雷电绕击的能力分析[J]. 电瓷避雷器,2001(6):22-25. HE Jin-liang,JIANG Zhou. Analysis on the withstanding capability of lines surge arresters for lightning shielding failure of transmission line[J]. Insulators and Surge Arresters,2001(6):22-25.
[13]  SZCZERBINSKI M. A discussion of ‘Faraday cage’ lightning protection and application to real building structures[J]. Elsevier-Journal of Electrostatics, 2000(48):145-154.
[14]  樊春雷,吴广宁,李瑞芳,等. 高压输电线路绕击跳闸率的研究[J]. 电瓷避雷器,2009(2):36-39. FAN Chun-lei,WU Guang-ning,LI Rui-fang. Study on shielding failure flashover rate for high voltage transmission line[J]. Insulators and Surge Arresters,2009(2):36-39.