[1] | 赵淳,阮江军,李晓岚,等. 输电线路综合防雷措施技术经济性评估[J]. 高电压技术,2011(2):290-297. ZHAO Chun,RU AN Jiangjun,LI Xiaolan,et al. Technology and economy evaluation of comprehensive transmission line lightning protection measures[J]. High Voltage Engineering,2011(2):290-297.
|
[2] | 梁方建,管珊莲,张回力,等. 单避雷线在输电线路防雷中的应用探讨[J]. 电瓷避雷器,2012(3):105-110. LIANG Fangjian,GUAN Shanlian,ZHANG Huili,et al.Application discussion on single lightning conductor in transmission line lightning protection[J]. Insulators and Surge Arresters,2012,03:105-110.
|
[3] | 李瑞芳,吴广宁,曹晓斌,等. 山区输电线路雷电绕击跳闸率的计算[J]. 电网技术,2010(12):142-146. LI Ruifang,WU Guangning,CAO Xiaobin,et al. Calculation of shielding failure trip-out rate for transmission lines in mountain areas[J]. Power System Technology,2010(12):142-146.
|
[4] | 杨庆,赵杰,司马文霞,等. 云广特高压直流输电线路反击耐雷性能[J]. 高电压技术,2008(7):1330-1335. YANG Qing,SIMA Wenxia,FENG Jie,et al. Research on the lighting shielding performance of the yun-guang UHVDC transmission lines[J]. High Voltage Engineering,2008,34(3):442-446.
|
[5] | 李志军,尹宜宜,戴敏,等. 特高压交流输电线路雷电流监测[J]. 高电压技术,2012(12):3338-3346. LI Zhijun,YIN Yiyi,DAI Min,et al. Observation technique of lighting current striking to UHVAC overhead transmission line[J]. High Voltage Engineering,2012(12):3338-3346.
|
[6] | 王兰义,赵冬一,胡淑慧,等. 线路避雷器的研究进展[J]. 电瓷避雷器,2011(1):26-34 WANG Lanyi,ZHAO Dongyi,HU Shuhui,et al. Development trends of line arresters[J]. Insulators and Surge Arresters,2011(1):26-34.
|
[7] | 张搏宇,苏宁,吕雪斌,等. 带串联间隙1 000 kV特高压交流输电线路避雷器关键技术参数分析[J]. 高电压技术,2013(3):618-622. ZHANG Boyu,SU Ning,LU Xuebin,et al. Analysis of key technical parameters of arresters used for 1 000 kV UHVAC transmission line with series gap[J]. High Voltage Engineering,2013(3):618-622.
|
[8] | 敬海兵,张彼德,邓浩,等. 线路避雷器对1 000 kV交流输电线路耐雷水平的影响分析[J]. 电瓷避雷器,2011(3):38-42. JING Haibing,ZHANG Bide,DENG Hao,et al. Analysis on the impact of line arrester on lightning withstand level for 1 000 kV AC transmission line[J]. Insulators and Surge Arresters,2011(3):38-42.
|
[9] | 李振,余占清,何金良,等. 线路避雷器改善同塔多回线路防雷性能的分析[J]. 高电压技术,2011(12):3120-3128. LI Zhen,YU Zhanqing,HE Jinliang,et al. Line surge arrester improving lighting protection performance of rasmission lines with multi-circuits in a tower[J]. High Voltage Engineering,2011(12):3120-3128.
|
[10] | 肖国斌,虞泽,俸世荣,等. 500 kV线路避雷器的设计与应用[J]. 电瓷避雷器,2009(3):26-30. XIAO Guobin,YU Ze,FENG Shirong,et al. Design and application of surge arresters for 500 kV A.C. power transmission lines[J]. Insulators and Surge Arresters,2009(3):26-30.
|
[11] | 万帅,陈家宏,谭进,等. ±500 kV直流输电线路用复合外套带串联间隙金属氧化物避雷器的研制[J]. 高电压技术,2012(10):2714-2720. WAN Shuani,CHEN Jiahong,TAN jin,et al. Development of polymericMOA with no-supporting series gap for ±500 kV DC transmission lines[J]. High Voltage Engineering,2012(10):2714-2720.
|
[12] | DL/T 815―2012. 交流输电线路用复合外套金属氧化物避雷器[S]. 北京:中国电力出版社,2012.
|
[13] | JB/T 10497-2005. 交流输电线路用复合外套有串联间隙金属氧化物避雷器[S]. 北京:中国机械出版社,2005.
|
[14] | IEC 60099-8-2011. 电涌放电器.第8部分:交流电架空输电和配电线路带外串联间隙(EGLA)的金属氧化物电涌放电器电压超过1 kV的系统[S].
|
[15] | 高玉明,吴维韩,欧阳昌宜. 有关线路避雷器标准和参数设计中的几个问题[J]. 中国电力,2001(2):55-59. GAO Yuming,WU Weihan,OUYANG Yichang. Disscussion and suggestion on standard and design of surge arresters for power transmission lines[J]. Electrical Power,2001(2):55-59.
|
[16] | 张益民,申萌,罗六寿,等. 带外串联间隙线路避雷器续流切断试验探讨[J]. 电瓷避雷器,2012(6):91-96. ZHANG Yimin,SHEN Meng,LUO Liushou,et al. Discussion on follow current interrupting test of externally gapped line arresters[J]. Insulators and Surge Arresters,2012(6):91-96.
|
[17] | Yoshihiro Ishizak,Kenji Tsuge,Misao Kobayashi. Specific Consideration on Follow Current Interruption and Anti-pollution Performance of External Series Gapped Type Line Surge Arrester (EGLA)[A]. CIGRE Colloquium in Croatia:2008.
|
[18] | TSUGE K,ISHZA KI Y,ISHIBE S. Verification Tests for Externally Gapped Line Surge Arrester (EGLA)[A]. CIGRE C4 Colloquium on Lightning and Power System, in Kuala Lumpur,2010:16-19.
|
[19] | 吴维韩,何金良,高玉明. 金属氧化物非线性电阻特性和应用[M]. 北京:清华大学出版社,1990.
|
[20] | ASIDA Toshiyuki,KOMATSU Kasuaki,ANJIKI Tomikazu. Development and commercialization of 66 kV to 275 kV polymer type transmission line arresters[J]. Toshiba Review,2009,64(10):54-57.
|
[21] | Light Duty Type External Gapped Line Arrester for Transmission Lines[J]. NGKレビュ?,2003(3):1-8.
|
[22] | ?ビスキャス.Light Duty-Type External Gapped Line Arrestor for Overhead Transmission Lines“SR-Horn”[J]. 古河?工??第120号2008(9 ):80-81.
|
[23] | 苑吉河. 输电线路绝缘子(串)交流污闪特性及放电过程的研究[D]. 重庆:重庆大学,2008.
|
[24] | Seta. Power Frequency and Short Term Voltage Flash-over Performance of long suspension insulator and bushing under wetted and polluted condition[R]. [S.L]CRIEPI Report,1964.
|
[25] | 崔江流,宿志一,车文俊,等. 2001年初东北、华北和河南电网大面积污闪事故分析[J]. 电力设备,2001(4):6-20. CUI Jiangliu,SU Zhiyi,CHE Wenjun,et al. Investigation analysis on large areas pollutant flashover faults in northeast north China and He nan power networks in early 2001[J]. Power Equipment,2001(4):6-20.
|
[26] | 宿志一.防止大面积污闪的根本出路是提高电网的基本外绝缘水平――对我国电网大面积污闪事故的反思[J].中国电力,2003(12):60-64. SU Zhiyi. To intensify basic external insulation level of power system-fundamental way for prevention of large-scale pollution falshover[J]. Electrical power,2003(12):60-64.
|
[27] | 宿志一,李庆峰. 我国电网防污闪措施的回顾和总结[J]. 电网技术,2010(12):124-130. SU Zhiyi,LI Qingfeng. Historical review and summary on measures against pollution flashover occurred in power grids in China[J]. Power System Technology,2010(12):124-130.
|
[28] | 马明,吕伟涛,张义军,等. 我国雷电灾害及相关因素分析[J]. 地球科学进展,2008(8):856-865. MA Ming,LU Weitao,ZHANG Yijun,et al. Analysis of lightning disasters in China and their correlative factors[J].Advances in Earth sc Ience,2008(8):856-865.
|
[29] | 马明,吕伟涛,张义军,等. 1997―2006年我国雷电灾情特征[J]. 应用气象学报,2008(4):393-400. MA Ming,LU Weitao,ZHANG Yijun,et al. Characteristics of lightning exposure in China from 1997 to 2006[J]. Journal of Applied Meteorologcal Science,2008(4):393-400.
|