Abstract:

风电变流器的可靠运行是风能转换系统中的重要关注对象。然而现有文献评估器件结温对变流器可靠性的影响时,却没有重视结温波动的影响,以致往往高估了风电变流器的可靠性。该文基于永磁同步风力发电机工作的恶劣环境,分别从切入运行风速、额定风速、切除停机风速、开关频率及功率因数的变化,造成变流器中器件结温幅值及其波动差别的角度出发,利用Coffin-Manson器件可靠性评估模型,评估网侧变流器可靠性的差异。以1MW风机结合实际风速数据为例进行分析论证,结果验证了理论分析的正确性。统计数据结果表明,额定风速及开关频率的变化对变流器可靠性的影响比较大。为了实现变流器的高可靠运行,风机宜在低风速切入运行,尽可能高的风速切除停机。

References

[1]  Tavner P J,van Bussel G J W,Spinato F.Machine and converter reliabilities in wind turbines[C]//3rd IET International Conference on Power Electronics, Machines and Drives.Dublin:IET,2006:127-130.
[2]  Boettcher M,Fuchs F W.Power electronic converters in wind energy systems considerations of reliability and strategies for increasing availability[C]//Conference on Power Electronics and Applications (EPE).Birmingham,United Kingdom:IEEE,2011:8-12.
[3]  Blaabjerg F,Liserre M,Ke Ma.Power electronics converters for wind turbine systems[J].IEEE Transactions on Industry Applications,2012,48(2):708-719.
[4]  Daily weather data of the Netherlands [EB/OL].2013[2013-01-http://www.knmi.nl/climatology/daily_data/download.html.
[5]  Infineon IGBT Module datasheet,FZ1200R17KE3 [EB/OL].2012[2012-09-.http://www.infineon.com.
[6]  Ribrant J,Bertling L M.Survey of failures in wind power systems with focus on Swedish wind power plants during 1997 - 2005[J].IEEE Transactions on Energy Conversion,2007,22(1):167-173.
[7]  Jangamshetti,S H,Rau V G.Site matching of wind turbine generators: a case study[J].IEEE Transactions on Energy Conversion,1999,14(4):1537-1543.
[8]  Held M,Jacob P,Nicoletti G,et al.Fast power cycling test of IGBT modules in traction application[C]// International Conference on Power Electronics and Drive Systems.Singapore:IEEE,1997:425-430.
[9]  孔学东,恩云飞.电子元器件失效分析与典型案例[M].北京:国防工业出版社,2006:10-15.Kong Xuedong,En Yunfei.Analysis of failure of electronic component and typical case[M].Beijing:National Defense Industry Press,2006:10-15(in Chinese).
[10]  Aten M,Towers G,Whitlry C,et al.Reliability comparison of matrix and other converter topologies [J].IEEE Trans on Aero Electronic Systems,2006,42(3):867-875.
[11]  Abdi B,Ranjbar A H,Gharehpetian G B,et al.Reliability consideration for parallel performance of semiconductor switches in high-power switching power modules [J].IEEE Transactions on Industrial Electronics,2009,56(6):2133-2139.
[12]  Hirschmann D,Tissen D,Schröder S,et al.Reliability prediction for inverters in hybrid electrical vehicles [J].IEEE Transactions on Power Electronics,2007,22(6):2511-2517.
[13]  Arifujjaman M,Iqbal M T,Quaicoe J E.A comparative study of the reliability of the power electronics in grid connected small wind turbine systems[C]//Conference on Electrical and Computer Engineering (ECE).Newfoundland,Canada:IEEE,2009:394-397.
[14]  Xie Kaigui,Jiang Zefu,Li Wenyuan.Effect of wind speed on wind turbine power converter reliability[J].IEEE Transactions on Energy Conversion,2012,27(1):96-104.
[15]  Wei Lixiang,Kerkman R J,Lukaszewski R A,et al.Analysis of IGBT power cycling capabilities used in doubly fed induction generator wind power system [J].IEEE Transactions on Industry Applications,2011,47(4):1794-1801.
[16]  孙青,庄亦琪,王锡吉,等.电子元器件可靠性工程[M].北京:电子工业出版社,2002:48-52.Sun Qing,Zhuang Yiqi,Wang Xiji,et al.Project of electronic component reliability[M].Beijing:Publishing House of Electronics Industry,2002:48-52(in Chinese).
[17]  Wei Lixiang,Kerkman R J,Lukaszewski R A.Evaluation of power semiconductors power cycling capabilities for adjustable speed drive[C]//IEEE Industry Applications Society (ISA) Annual Meeting.Alberta,Canada:IEEE,2008:1-10.
[18]  Fox B,Flynn D,Bryans L,et al.Wind power integration connection and system operational aspects[M].London:The Institution of Engineering and Technology,2007:56-59.
[19]  Singh B,Kasal G K.Voltage and frequency controller for a small scale wind power generation[J].Asia Power Electronics Journal, 2008,2(1):37-43.
[20]  潘武略,徐政,张静,等.电压源换流器型直流输电换流器损耗分析[J].中国电机工程学报,2008,28(21):7-14.Pan Wulue,Xu Zheng,Zhang Jing,et al.Dissipation analysis of VSC-HVDC converter[J].Proceedings of the CSEE,2008,14(4):1537-1543(in Chinese).
[21]  Weckert M,Roth-Stielow J.Chances and limits of a thermal control for a three-phase voltage source inverter in traction applications using permanent magnet synchronous or induction machines[C]//Conference on Power Electronics and Applications (EPE).Birmingham,UK:IEEE,2011:1-10.
[22]  Schulz M.Thermal interface - a key factor in improving lifetime in power electronics[C]//Proceedings PCIM Annual Meeting.Nuremberg:PCIM,2012:1-5.
[23]  Potential wind speed of the Netherlands [EB/OL].2012[2012-09-http://www.knmi.nl/klimatologie/onderzoeksgegevens/potentiele_wind/index.cgi?language=eng.