Chen Juan,He Yingjie,Wang Xinyu.Research of the unity theory between three-level space vector and carrier-based PWM modulation strategy[J].Proceedings of the CSEE,2013,33(9):71-79(in Chinese).
[2]
G H.Optimized active harmonic elimination technique for three-level T-type inverters[J].Power Electronics,2013,6(3):425-433.
[3]
S B,Yaragatti U R,Beig A R.Space vector-based synchronised bus-clamping pulse width modulation algorithms for three-level voltage source inverter in over-modulation region[J].Power Electronics,2012,5(4):493-500.
[4]
Jiang Weidong,Yang Bowang,Huang Jing,et al.Comparisons of the neutral point voltage balancing algorithm for NPC three-level inverters based on different zero-swquence voltage injection[J].Proceedings of the CSEE,2013,33(33):17-25(in Chinese).
[5]
Wang Jiuhe.The power converter and its passive-based control[M].Beijing:Science Publisher,2014(in Chinese).
[6]
Sun Chao,Yan Cheng,Zhang Yangfan,et al.Research on two modulation scheme of three-level T-type grid- connected inverter[J].Power Technology,2013(3):42-47(in Chinese).
[7]
L Corral Martinez,马柯,李睿,等.三电平和两电平逆变器效率分析与比较[J].电力电子技术,2009(7):1-2+22. Boris L Corral Martinez,Ma Ke,Li Rui,et all.Efficiency analysis and comparison of three-level and two-level inverters[J].Power Electronics Technology,2009(7):1-2+22(in Chinese).
[8]
Chinese). Teng Zhaobo,Yu Haisheng,Yu Jingpeng.The PCH modeling and control of PWM rectifier with resistance and inductance load[J].Qingdao University:Engineering & Technology Edition,2012(2):36-42(in Chinese).
[9]
M,Kola J W.Design and implementation of a highly efficient three-level T-type converter for low-voltage applications[J].IEEE Transactions on Power Electronics,2013:899-907.
[10]
U M,Lee K B,Blaabjerg F.Diagnosis and tolerant strategy of an open-switch fault for t-type three-level inverter systems[J].IEEE Transactions on Industry Applications,2014:495-508.
[11]
Zhangping,Zhang Xing,Wang Fusheng,et al.Modeling and elimination of zero-sequence circulating currents in parallel three-level T-type grid-connected inverters[J].IEEE Transactions on Power Electronics,2015,30(2):1050-1063.
[12]
Y,Sul S K,Lim C H,et al. Asymmetric control of DC-link voltages for separate MPPTs in three-level inverters[J].IEEE Transactions on Power Electronics,2013,28(6):2760-2769.
[13]
Li,Sun Kai,Fang Yu.An optimized common mode voltage reduction PWM strategy for T-type three phase three level photovoltaic grid-tied inverter [C]//Energy Conversion Congress and Exposition.IEEE,2013:1623-1627.
[14]
Wenping,Liu Guangyuan,Xu Dehong,et al.A fault-tolerant T-type three-level inverter system [C]//Applied Power Electronics Conference and Exposition (APEC).IEEE,2014:274-280.
[15]
Wang,Shi W W,Xie N,et al.Diode-free T-type three-level neutral-point-clamped inverter for low-voltage renewable energy system[J].IEEE Transactions on Industrial Electronics,2014,61(11):6168-6174.
[16]
Fan Bishuang,Tan Guangzheng,Fan Shaosheng,et al.A new DC side capacitance voltages balancing method for three-level inverters based on hybrid space vector modulation[J].Proceedings of the CSEE,2012,32(27):135-141(in Chinese).
[17]
U,Lee J S,Lee K B.New modulation strategy to balance the neutral-point voltage for three-level neutral-clamped inverter systems[J].IEEE Transactions on Energy Conversion,2014,29(1):91-100.
[18]
U M,Lee H H,Lee K B.Simple neutral-point voltage control for three-level inverters using a discontinuous pulse width modulation[J].IEEE Transactions on Energy Conversion,2013,28(2):434-443.
[19]
V F,Foito D,Sousa D M.Conversion structure based on a dual T-type three-level inverter for grid connected photovoltaic applications[C]//2014 IEEE 5th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).IEEE,2014:24-27.
[20]
Zhou Jinghua,Jia Bin,Zhang Xiaowei,et al.A hybrid three-level neutral-point balance control strategy [J].Proceedings of the CSEE,2013,33(24):82-89(in Chinese).