邢颖,李宝树.非线性负荷对电网电压和电流的影响[J].电力系统,2007,26(8):25-28. Xing Ying,Li Baoshu.The impact of nonlinear load on the voltage and current of the grid[J].Power System,2007,26(8):25-28(in Chinese).
[2]
Yuan Haiwen,Qin Ye,Zhao Cheng,et al.Research on harmonic current distribution of Beijing’s rail traffic power supply system[C]//9th International Conference on Electronic Measurement & Instruments.Beijing,China:The Chinese Institute of Electronics,2009:235-238.
[3]
胡泽春,宋永华,徐智威,等.电动汽车接入电网的影响与利用[J].中国电机工程学报,2012,32(4):1-10. Hu Zechun,Song Yonghua,Xu Zhiwei,et al.Impacts and utilization of electric vehicles integration into power systems[J].Proceedings of the CSEE,2012,32(4):1-10(in Chinese).
[4]
高云鹏,滕召胜,温和,等.凯塞窗插值FFT的电力谐波分析与应用[J].中国电机工程学报,2010,30(4):43-48. GaoYunpeng,Teng Zhaosheng,Wen He,et al.Harmonic analysis on Kaiser window interpolation FFT and application[J].Proceedings of the CSEE,2010,30(4):43-48(in Chinese).
[5]
严伟佳,蒋平,李峰.谐波对电能计量影响的研究[J].华东电力,2006,34(2):40-42. Yan Weijia,Jiang Ping,Li Feng.Effects of harmonics on electric energy metering[J].East China Electric Power,2006,34 (2) :40-42(in Chinese).
[6]
谭志强,彭楚宁.冲击负荷对电能计量的影响[J].电测与仪表,2003,40(1):41-43. Tan Zhijiang,Peng Chuning.The influence on electric energy measurement under the condition of impulse load[J].Electrical Measurement & Instrument,2003,40(1):41-43(in Chinese).
[7]
粟时平,王长城,金维宇.冲击负荷电能计量理论与算法研究[J].电测与仪表,2004,41(10):1-4,46. Su Shiping,Wang Changcheng,Jin Weiyu.Study on theory and arithmetic of electric energy measurement for impact load[J].Electrical Measurement & Instrument,2004,41(10):1-4,46 (in Chinese).
[8]
周莉,刘开培.电能计量误差分析与电能计费问题的讨论[J].电工技术学报,2005,20(2):63-68. Zhou Li,Liu Kaipei.Error analyzing electrical metering and discussion about pricing of electric energy [J].Transactions of China Electro Technical Society,2005,20(2):63-68(in Chinese).
[9]
Driesen J,Belmans R.Power measurement using the wavelet transform of analytic signals[C]//11th International Conference on Harmonics and Quality of Power.AES Sul,Sao LeopoIdo,Brazil:IEEE,2004:338-342.
[10]
Durnte L G,Ghosh P K.Active power measurement in nonsinusoidal environments[J].IEEE Transactions on Power Systems,2000,5(3):1142-1147.
[11]
张晓冰.畸变信号条件下电网功率潮流分析与电能计量新方法研究[D].哈尔滨:哈尔滨理工大学,2007. Zhang Xiaobing.Electrical network power flow analysis and research on new measuring methods of electric energy methods of electric energy on the condition of distortion signals[D].Harbin:Harbin University of Science and Technology,2007(in Chinese).
[12]
Georgios D M.The Volterra-Wiener approach in neuronal modeling[C]//33rd Annual International conference of the IEEE EMBC.Boston,USA:IEEE,2011:5912-5915.
[13]
Mkadem F,Wu D Y,Boumaiza S.Wiener-G functionals for nonlinear power amplifier digital predistortion[C]// 2012 IEEE MTT-S International Microwave Symposium Digest (MTT).Montreal,Canada:IEEE,2012:1-3.
[14]
Mkadem F,Boumaiza S,Staudinger J,et al.Systematic pruning of volterra series using Wiener-G functionals for power amplifier and predistorter modeling [C]//Proceedings of the 6th European Microwave Integrated Circuits Conference.Manchester,UK:IEEE,2011:482-485.
[15]
焦李成.非线性传递函数理论与应用[M].西安:西安电子科技大学出版社,1992:52-57,264-282. Jiao Licheng.The nonlinear transfer function theory and application[M].Xi’an:Xi’an University of Electronic Science and Technology Press,1992:52-57,264-282(in Chinese).
[16]
Wilson J R.Non-linear system theory the volterra/ wiener approach[M].Baltimore:The Johns Hopkins University Press,1981:303-326.
[17]
Power System Instrumentation and Measurements Committee.1459-2010-IEEE Standard Definitions for the measurement of electric power quantities under sinusoidal, non-sinusoidal, balanced, or unbalanced conditions [S].New York:IEEE,2010.
[18]
Franz M O,Scholkopf B.A unifying view of Wiener and volterra theory and polynomial kernel regression [J].Neural computation,2006,18(12):3097-3118.
[19]
Chen Y,Liu Z Y,Zhang H J.Research and simulation of volterra series Kernel identification on Wiener model [C]//Environmental Science and Information Application Technology.Wuhan,China:IEEE,2010:95-98.
[20]
Yokota Y,Toda N,Usui S.Method for determining the optimum input power level in Wiener kernel measurement[C]//14th Annual International Conference of the IEEE Engineering in Medicine and Biology.Paris,France:IEEE,1992:2598-2599.
[21]
Yokota Y,Todaand N,Usui S.Precision analysis of wiener kernels measured by cross-correlation method [J].Electronics and Communications in Japan,1993,76(3):13-22.