微电网系统中基于双二阶滤波器的主动阻尼方法

, PP. 261-268

Keywords: 双二阶滤波器,主动阻尼,LCL滤波器,微电网

Full-Text   Cite this paper   Add to My Lib

Abstract:

微电网系统中的电力电子接口变换器通常呈并联结构,且通过LCL滤波器连接到公共母线。LCL滤波器自身具有谐振问题,特别是在并联逆变器系统中,频域分析结果中存在额外的正向谐振尖峰和反向谐振尖峰。本文在分析微电网中带有LCL滤波器的并联逆变器系统谐振特性的基础上,采用基于双二阶滤波器的主动阻尼方法,在不引入额外的传感器和控制闭环的情况下,对并联系统中多对不稳定极点同时进行调整。该方法通过在控制系统中添加两对零极点,改变根轨迹的走向,使得多对不稳定极点均移动到z平面单位圆之内,因此系统稳定性得以保证。基于dSPACE1103搭建的实时仿真模型表明了理论分析结果。

References

[1]  张纯江, 王晓寰, 薛海芬, 等. 微网中三相逆变器类功率下垂控制和并联系统小信号建模与分析[J]. 电工技术学报, 2012, 27(1): 32-39.
[2]  Zhang Chunjiang, Wang Xiaohuan, Xue Haifen, et al. a quasi-power droop control of three-phase inverters and small signal modeling and analysis of parallel system in micro-grid[J]. Transactions of China Electrotechnical Society, 2012, 27(1): 32-39.
[3]  Guerrero J M, Hang L, Uceda J. Control of distributed uninterruptible power supply systems[J]. IEEE Transactions on Industry Electronics, 2008, 55(8): 2845-2859.
[4]  Liserre M, Blaabjerg F, Hansen S. Design and control of an LCL-filter-based three-phase active rectifier [J]. Transactions on Industry Applications, 2005, 41(5): 1281-1291.
[5]  Liserre M, Aquila A D, Blaabjerg F. Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier[J]. IEEE Transactions on Power Electronics, 2004, 19(1): 76-86.
[6]  Teodorescu R, Liserre M, Rodriguez P. Grid converters for photovoltaic and wind power systems [M]. Wiley, 2011.
[7]  Agorreta J L, Borrega M, Lopez J, Marroyo L. Modeling and control of N-paralleled grid-connected inverters with LCL filter coupled due to grid impedance in PV plants[J]. IEEE Transactions on Power Electronics, 2011, 26(3): 770-785.
[8]  王飞, 余世杰, 苏建徽, 等. 太阳能光伏并网发电系统的研究[J]. 电工技术学报, 2005, 20(5): 72-74, 91.
[9]  Wang Fei, Yu Shijie, Su Jianhui, et al. Research on Photovoltaic grid-connected power system[J]. Transactions of China Electrotechnical Society, 2005, 20(5): 72-74, 91.
[10]  刘其辉, 贺益康, 赵仁德. 交流励磁变速恒频风力发电系统的运行与控制[J]. 电工技术学报, 2008, 23(1): 129-136.
[11]  Liu Qihui, He Yikang, Zhao Rende. Operation and control of AC-exited variable-speed constant- frequency wind power generation system [J]. Transactions of China Electrotechnical Society, 2008, 23(1): 129-136.
[12]  Lasseter R, Akhil A, C Marnay, et al. The certs microgrid concept-white paper on integration of distributed energy resources [R]. Technical Report, U.S. Department of Energy, April, 2002.
[13]  Chris Marnay, Owen C Bailey. The CERTS microgrid and the future of the macrogrid [C]. ACEEE Summer Study on Energy Efficiency in Buildings, 2004.
[14]  Blaabjerg F, Chen Z, Kjaer S B. Power electronics as efficient interface in dispersed power generation systems[J]. IEEE Transactions on Power Electronics, 2004, 19(5): 1184-1194.
[15]  Carrasco J M, Franquelo L G, Bialasiewicz J T, et al. Power-electronic systems for the grid integration of renewable energy sources: a survey[J]. IEEE Transactions on Industry Electronics, 2006, 53(4): 1002-1016.
[16]  沈坤, 章兢, 王坚. 基于PQ下垂控制逆变器并联技术的列车辅助供电系统研究[J]. 电工技术学报, 2011, 26(7):223-229.
[17]  Shen Kun, Zhang Jing, Wang Jian. Research on train auxiliary power system based on PQ droop control inverter parallel technology[J]. Transactions of China Electrotechnical Society, 2011, 26(7): 223-229.
[18]  He J, Li Y W, Bosnjak D, et al. Investigation and active damping of multiple resonances in a parallel- inverter-based microgrid[J]. IEEE Transactions on Power Electronics, 2013, 28(1): 234-246.

Full-Text