化工学报  2015 

考虑温度约束的单杂质水网络优化

DOI: 10.11949/j.issn.0438-1157.20150142, PP. 2581-2587

Keywords: 水网络,优化,热集成,全过程系统

Full-Text   Cite this paper   Add to My Lib

Abstract:

实际用水过程有温度的要求,在用水网络集成中考虑温度的约束,使水耗和能耗同时降低,具有重要的意义。此外,过程系统中还存在只有温度限制的与用水无关的过程流股,将水网络中的水流股与其同时考虑热集成,可以使能量得到更合理的分配利用。在全过程系统能量集成的背景下,建立了对应的水网络优化方法。首先使用现有的废水直接回用水网络LP模型求解初始水网络并提取流股数据,然后在4条非等温混合规则的判断下,依次比较水网络流股与背景夹点、全过程夹点的关系,以排除不合理的非等温混合,最后以年总费用最低为目标进行全过程系统的热集成。使用本文提出的方法对某案例进行优化,得到的年总费用减少了6.27%,证明了该方法的可行性。

References

[1]  Wang Y P, Smith R. Wastewater minimisation [J]. Chem. Eng. Sci., 1994, 49 (7): 981-1006.
[2]  Dhole V R, Ramchandani N, Tainsh R A, Wasilewski M. Make your process water pay for itself [J]. Chem. Eng., 1996, 103 (1): 100-103.
[3]  Hallale N. A new graphical targeting method for water minimisation [J]. Adv. Environ. Res., 2002, 6 (3): 377-390.
[4]  Manan Z A, Tan Y L, Foo D C Y. Targeting the minimum water flow rate using water cascade analysis technique [J]. AIChE J., 2004, 50 (12): 3169-3183.
[5]  Prakash R, Shenoy U V. Targeting and design of water networks for fixed flowrate and fixed contaminant load operations [J]. Chem. Eng. Sci., 2005, 60 (1): 255-268.
[6]  Takama N, Kuriyama T, Shiroko K, et al. Optimal water allocation in a petroleum refinery [J]. Computers & Chemical Engineering, 1980, 4 (4): 251-258.
[7]  Savelski M J, Bagajewicz M J. On the optimality conditions of water utilization systems in process plants with single contaminants [J]. Chem. Eng. Sci., 2000, 55 (21): 5035-5048.
[8]  Bagajewicz M, Savelski M. On the use of linear models for the design of water utilization systems in process plants with a single contaminant [J]. Chemical Engineering Research & Design, 2001, 79 (A5): 600-610.
[9]  Teles J, Castro P M, Novals A Q. LP-based solution strategies for the optimal design of industrial water networks with multiple contaminants [J]. Chem. Eng. Sci., 2008, 63 (2): 376-394.
[10]  Savulescu L, Kim J K, Smith R. Studies on simultaneous energy and water minimisation (Ⅰ): Systems with no water re-use [J]. Chem. Eng. Sci., 2005, 60 (12): 3279-3290.
[11]  Savulescu L, Kim J K, Smith R. Studies on simultaneous energy and water minimization (Ⅱ): Systems with maximum re-use of water [J]. Chem. Eng. Sci., 2005, 60 (12): 3291-3308.
[12]  Leewongtanawit B, Kim J K. Improving energy recovery for water minimisation [J]. Energy, 2009, 34 (7): 880-893.
[13]  Bagajewicz M, Rodera H, Savelski M. Energy efficient water utilization systems in process plants [J]. Comput. Chem. Eng., 2002, 26 (1): 59-79.
[14]  Liao Zuwei (廖祖维), Yang Yongrong (阳永荣), Wang Jingdai (王靖岱), Jiang Binbo (蒋斌波). Optimization of energy efficient water utilization systems [J]. Journal of Chemical Industry and Engineering (China) (化工学报), 2007, 58 (2): 396-402.
[15]  Liao Zuwei, Wu Jintao, Jiang Binbo, Wang Jingdai, Yang Yongrong. Design energy efficient water utilization systems allowing operation split [J]. Chin. J. Chem. Eng., 2008, 16 (1): 16-20.
[16]  Mao Tingbi (毛庭璧), Luo Yiqing (罗祎青), Yuan Xigang (袁希钢). Design method of heat intergrated water networks considering non-isothermal mixing [J]. CIESC Journal (化工学报), 2010, 61 (2): 369-377.
[17]  Liao Z, Rong G, Wang J, Yang Y. Systematic optimization of heat-integrated water allocation networks [J]. Ind. Eng. Chem. Res., 2011, 50 (11): 6713-6727.
[18]  Huang C H, Chang C T, Ling H C, Chang C C. A mathematical programming model for water usage and treatment network design [J]. Ind. Eng. Chem. Res., 1999, 38 (7): 2666-2679.
[19]  Liu Zuming (刘祖明), Luo Yiqing (罗祎青), Yuan Xigang (袁希钢). Synthesis of heat-integrated water allocation network considering non-isothermal mixing [J]. CIESC Journal (化工学报), 2014, 65 (1): 285-291.[20] Du Jian (都健). Study on design of water utilization network involving energy intergration and flexibility [D]. Dalian: Dalian University of Technology, 2004