Physics  2015 

Investigation of the Kyoto's X-ray Astronomical SOIPIXs with Double-SOI Wafer for Reduction of Cross-talks

Full-Text   Cite this paper   Add to My Lib

Abstract:

We have been developing X-ray SOIPIXs, "XRPIX", for future X-ray astronomy satellites. XRPIX is equipped with a function of "event-driven readout", which allows us to readout signal hit pixels only and realizes a high time resolution ($\sim10\mu{\rm s}$). The current version of XRPIX suffers a problem that the readout noise in the event-driven readout mode is higher than that in the the frame readout mode, in which all the pixels are read out serially. Previous studies have clarified that the problem is caused by the cross-talks between buried P-wells (BPW) in the sensor layer and in-pixel circuits in the circuit layer. Thus, we developed new XRPIX having a Double SOI wafer (DSOI), which has an additional silicon layer (middle silicon) working as an electrical shield between the BPW and the in-pixel circuits. After adjusting the voltage applied to the middle silicon, we confirmed the reduction of the cross-talk by observing the analog waveform of the pixel circuit. We also successfully detected $^{241}$Am X-rays with XRPIX.