Sensors  2013 

Array of Hall Effect Sensors for Linear Positioning of a Magnet Independently of Its Strength Variation. A Case Study: Monitoring Milk Yield during Milking in Goats

DOI: 10.3390/s130608000

Keywords: Hall effect sensors, milk yield, multiple regression, linear magnet position

Full-Text   Cite this paper   Add to My Lib

Abstract:

In this study we propose an electronic system for linear positioning of a magnet independent of its modulus, which could vary because of aging, different fabrication process, etc. The system comprises a linear array of 24 Hall Effect sensors of proportional response. The data from all sensors are subject to a pretreatment (normalization) by row (position) making them independent on the temporary variation of its magnetic field strength. We analyze the particular case of the individual flow in milking of goats. The multiple regression analysis allowed us to calibrate the electronic system with a percentage of explanation R 2 = 99.96%. In our case, the uncertainty in the linear position of the magnet is 0.51 mm that represents 0.019 L of goat milk. The test in farm compared the results obtained by direct reading of the volume with those obtained by the proposed electronic calibrated system, achieving a percentage of explanation of 99.05%.

References

[1]  Billon, P.; Chastin, P.; Baritaux, B.; Bouvier, F.; Ilahi, H.; Manfredi, E.; Marnet, P.G. La cinétique d'émission du lait chez les chèvres. In Milking and Milk Production of Dairy Sheep and Goats; Zervas, N., Barillet, F., Eds.; EAAP Publication Wageningen Pers: Wageningen, The Netherlands, 1999; Volume 95, pp. 51–58.
[2]  Ricordeau, G.; Martinet, J.; Denamur, R. Traite à la machine des brebis préalpes du Sud. Importance des différentes opérations de la traite. Ann. Zootech. 1963, 12, 203–225.
[3]  Barillet, F. Genetic improvement for dairy production in sheep and goats. Small Rumin. Res. 2007, 70, 60–75.
[4]  Ricard, E.; Arhainx, J.; Guillouet, J.P.; Bouvier, F.; Jacquin, M.; Chastin, P.; Astruc, J.M.; Lagriffoul, G.; Manfredi, E.; Barillet, F. On-farm test of INRA portable electronic jars for automatized milk recording of sheep and goats. In Performance recording of animals; Gailon, P., Chambert, Y., Eds.; EAAP Publication Wageningen Wageningen Pers: Wageningen, The Netherlands, 1994; Volume 50, pp. 47–51.
[5]  Ilahi, H.; Chastin, P.; Bouvier, F.; Arhainx, J.; Ricard, E.; Manfredi, E. Milking characteristics of dairy goats. Small Rumin. Res. 1999, 34, 97–102.
[6]  Ait-Saidi, A.; Caja, G.; Carné, S.; Salama, A.; Ghirardi, J.J. Short communication: Comparison of manual versus semiautomatic milk recording systems in dairy goats. J. Dairy Sci. 2008, 91, 1438–1442.
[7]  Nishio, T.; Chen, Q.; Gillijns, W.; De Keyser, K.; Vervaeke, K.; Moshchalkov, V.V. Scanning Hall probe microscopy of vortex patterns in a superconducting microsquare. Phys. Rev. B. 2008, 77, 012502.
[8]  Smith, C.H.; Schneider, R.W.; Dogaru, T.; Smith, S.T. Eddy-current testing with GMR magnetic sensor arrays. In Review of Progress in Quantitative Nondestructive Evaluation, Proceedings of the Quantitative Nondestructive Evaluation Conference, Green Bay, WI, USA, 28 July 2003; Thompson, D.O., Chimenti, D.E., Eds.; American Institute of Physics: Melville, NY, USA; Vol. 23, pp. 68–73.
[9]  Kim, J.; Lee, J.; Jun, J.; Le, M.; Cho, C. Integration of Hall and giant magnetoresistive sensor arrays for real-time 2-D visualization of magnetic field vectors. IEEE T. Magn. 2012, 48, 3708–3711.
[10]  Benitez, D.; Gaydecki, P.; Quek, S.; Torres, V. Development of a solid-state multi-sensor array camera for real time imaging of magnetic fields. J. Phys. Conf. Ser. 2007, 76, 012030.
[11]  Koen, V. Inspection of magnetization vector and magnetic field distribution of uniaxial and multipole sensor magnets using fast high resolution MagCam magnetic field mapping and analysis. Proc. Sensor Proc. 2011, 1, 762–767.
[12]  Jun, J.; Kim, J.; Lee, J.; Park, Y. A hand-held magnetic camera system for real time crack inspection. Proceedings of the IEEE Sensors Applications Symposium, San Antonio, TX, USA, February 2011; pp. 298–301.
[13]  Misron, N.; Shin, N.W.; Shafie, S.; Marhaban, M.H.; Mailah, N.F. A mobile ferromagnetic shape detection sensor using a Hall sensor array and magnetic imaging. Sensors. 2011, 11, 10474–10489.
[14]  Allegro Microsystems LLC. Continuous-Time Ratiometric Linear Hall Effect Sensor ICs. Available online: http://www.allegromicro.com/?/media/Files/Datasheets/A1301–2-Datasheet.ashx (accessed on 30 January 2013).
[15]  Arduino Open-Source Electronics Prototyping Platform. Available online: http://www.Arduino.cc (accessed on 20 June 2013).
[16]  R-27–16–05-N Magnet. Available online: http://www.supermagnete.es/R-27–16–05-N (accessed on 30 January 2013).
[17]  Lemarquand, G.; Lemarquand, V.; Babic, S.; Akyel, C. Magnetic Field Created by Thin Wall Solenoids and Axially Magnetized Cylindrical Permanent Magnets. Proceedings of the Progress In Electromagnetics Research Symposium 2009 (PIERS 2009), Moscow, Russia, 18-21August 2009; Volume 1, pp. 614–618.
[18]  Ravaud, R.; Lemarquand, G.; Lemarquand, V.; Depollier, C. The three exact components of the magnetic field created by a radially magnetized tile permanent magnet. Prog. Electromagnet. Res. 2008, 88, 307–319.
[19]  Fisher, R.A. Statistical Methods for Research Workers; Oliver and Boyd: Edinburgh, UK, 1925.
[20]  Kutman, M.H.; Nachtsheim, J.; Nefer, J.; Li, W. Applied Linear Statistical Models; McGraw Hill: New York, NY, USA, 2005.
[21]  Gallagher, N.B.; Wise, B.M.; Stewart, C.W. Application of multi-way principal components analysis to nuclear waste storage tank monitoring. Comput. Chem. Eng. 1996, 20, 739–744.
[22]  R?nnar, S.; MacGregor, J.F.; Wold, S. Adaptive batch monitoring using hierarchical PCA. Chemom. Intell. Lab. Syst. 1998, 41, 73–81.
[23]  Zarzo, M.; Ferrer, A. Batch process diagnosis: PLS with variable selection versus block-wise PCR. Chemom. Intell. Lab. Syst. 2004, 73, 15–27.
[24]  García-Diego, F-J.; Zarzo, M. Microclimate monitoring by multivariate statistical control: The renaissance frescoes of the Cathedral of Valencia (Spain). J. Cult. Herit. 2010, 11, 339–344.
[25]  Zarzo, M.; Fernández-Navajas, A.; García-Diego, F-J. Long-term monitoring of fresco paintings in the Cathedral of Valencia (Spain) through humidity and temperature sensors in various locations for preventive conservation. Sensors 2011, 11, 8685–8710.
[26]  Statgraphics 5.1. Available online: http://www.statgraphics.net (accessed on 20 June 2013).