Sensors  2013 

Identification of Capacitive MEMS Accelerometer Structure Parameters for Human Body Dynamics Measurements

DOI: 10.3390/s130911184

Keywords: capacitive, accelerometer, MEMS, optimization, proof-mass, L-shaped beam

Full-Text   Cite this paper   Add to My Lib

Abstract:

Due to their small size, low weight, low cost and low energy consumption, MEMS accelerometers have achieved great commercial success in recent decades. The aim of this research work is to identify a MEMS accelerometer structure for human body dynamics measurements. Photogrammetry was used in order to measure possible maximum accelerations of human body parts and the bandwidth of the digital acceleration signal. As the primary structure the capacitive accelerometer configuration is chosen in such a way that sensing part measures on all three axes as it is 3D accelerometer and sensitivity on each axis is equal. Hill climbing optimization was used to find the structure parameters. Proof-mass displacements were simulated for all the acceleration range that was given by the optimization problem constraints. The final model was constructed in Comsol Multiphysics. Eigenfrequencies were calculated and model’s response was found, when vibration stand displacement data was fed into the model as the base excitation law. Model output comparison with experimental data was conducted for all excitation frequencies used during the experiments.

References

[1]  Ananthasures, G.K. Optimal Synthesis Methods for MEMS; Springer US: New York, NY, USA, 2003; p. 150.
[2]  Mukherjee, T.; Zhou, Y.; Fedder, G.K. Automated Optimal Synthesis of Microaccelerometers. Proceedings of the 12th IEEE International Conference on Micro Electro Mechanical Systems (MEMS'99), Orlando, FL, USA, 17–21 January 1999; pp. 326–331.
[3]  Yuan, W.Z.; Chang, H.L.; Li, W.J.; Ma, B.H. Application of an optimization methodology for multidisciplinary system design of microgyroscopes. Microsyst. Technol. 2006, 12, 315–323.
[4]  Tay, F.E.; Jun, X.; Logeeswaran, V.J. Optimization Methodology for Low-g Microaccelerometer. In Micromachining and Microfabrication; Chau, K.H., Parameswaran, M., Tay, F.E., Eds.; SPIE: Bellingham, WA, USA, 2000; Volume 4230, pp. 128–139.
[5]  Pedersen, C.B.W.; Seshia, A.A. On the optimization of compliant force amplifier mechanisms for surface micromachined resonant accelerometers. J. Micromech. Microeng. 2004, 14, 1281–1293.
[6]  Ostasevicius, V.; Gaidys, R.; Dauksevicius, R. Numerical analysis of dynamic effects of a nonlinear vibro-impact process for enhancing the reliability of contact-type MEMS devices. Sensors 2009, 9, 10201–10216.
[7]  Tarabini, M.; Saggin, B.; Scaccabarozzi, D.; Moschioni, G. The potential of micro-electro-mechanical accelerometers in human vibration measurements. J. Sound Vib. 2012, 331, 487–499.
[8]  Lee, H.; Park, J.W.; Helal, A. Estimation of Indoor Physical Activity Level Based on Footstep Vibration Signal Measured by MEMS Accelerometer in Smart Home Environments. Proceedings of the 2nd International Conference on Mobile Entity Localization and Tracking in GPS -Less Environments (MELT'09), Orlando, FL, USA, 30 September 2009; pp. 148–162.
[9]  Bliley, K.E.; Schwab, D.J.; Holmes, D.R., III; Kane, P.H.; Levine, J.A.; Daniel, E.S.; Gilbert, B.K. Design of a Compact System Using a MEMS Accelerometer to Measure Body Posture and Ambulation. Proceedings of the 19th IEEE International Symposium on Computer-Based Medical Systems (CBMS 2006), Salt Lake City, UT, USA, 22–23 June 2006; pp. 335–340.
[10]  Bouten, C.V.C.; Koekkoek, K.T.M.; Verduin, M.; Kodde, R.; Janssen, J.D. A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE Trans. Biomed. Eng. 1997, 44, 136–147.
[11]  Armin, G. Fundamentals of videogrammetry—A review. Hum. Mov. Sci. 1997, 16, 155–187.
[12]  Benevicius, V.; Ostasevicius, V.; Gaidys, R. Human body rheology impact on measurements in accelerometer applications. Mechanics 2013, 19, 40–45.
[13]  Ledoux, W.R.; Hillstrom, H.J. Acceleration of the calcaneus at heel strike in neutrally aligned and pes planus feet. Clin. Biomech. 2001, 16, 608–613.
[14]  Qu, H.; Fang, D.; Xie, H.A. Monolithic CMOS-MEMS 3 axis accelerometer with low noise, low power dual chopper amplifier. IEEE Sens. J. 2008, 8, 1511–1518.
[15]  Reilly, S.P.; Leach, R.K.; Cuenat, A.; Awan, S.A.; Lowe, M. Overview of MEMS Sensors and the Metrology Requirements for their Manufacture. NPL Report DEPC-EM 008; National Phsycial Laboratory: London, UK, 2006.
[16]  Yoshida, K.; Matsumoto, Y.; Ishida, M.; Okada, K. High-Sensitive Three Axis SOI Capacitive Accelerometer Using Dicing Method. Proceedings of Technical Digest of the 16th Sensor Symposium, Toyohashi, Japan, 2–3 June 1998; pp. 25–28.