THE EFFECT OF THE SLUDGE RECYCLE RATIO IN AN ACTIVATED SLUDGE SYSTEM FOR THE TREATMENT OF AMOL'S INDUSTRIAL PARK WASTEWATER

Keywords: activated sludge , COD removal , industrial effluents , sludge recycle ratio , SVI

Full-Text   Cite this paper   Add to My Lib

Abstract:

An activated sludge aeration tank and a sedimentation basin were used to treat Amol’s industrial park effluents originating from all industrial units. A continuous system was implemented and the kinetic parameters were measured.The parameters such as rate constant, substrate utilization rate constant, yield and decay coefficient were 2.12 d-1, 232.4 mg l-1, 0.33 g/g of substrate and 0.096 d 1, respectively. The hydraulic retention times (HRT) were in the range of 9 to 27 h. The sludge recycle ratios in the range from 0.3 to 1 were considered. The COD removal, SVI and DO were determined and the optimal values were obtained. It was observed that at HRT of 16 h and the sludge recycle ratio of 0.85, the COD removal and SVI were 95 and 85 %, respectively. The sludge recycle ratio greater than 0.85 had no significant effect on the COD removal.