全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Morphometric Study of the Proximal Femur Extremity in Brazilians Estudio Morfométrico del Extremo Proximal del Fémur en Brasile os

Keywords: Fémur , Morfometría , Anatomía , Femur , Morphometry , Anatomy

Full-Text   Cite this paper   Add to My Lib

Abstract:

Brazilian populational aging besides higher life expectancy has increased the incidence of proximal femoral fractures. Treatment of those fractures uses implants which are based in measurements performed in caucasians, including the 135 degrees cervical-diaphyseal angle. Knowing femoral morphometry allows evaluating implants adequability. We performed our study using 110 Brazilian human femurs (49 right and 61 left). We excluded from the study: bones submitted to osteosyntesis, to prosthetization or those showing abnormalities or malformations which could affect its structure and shape. Bones were submitted to roetgenographic analysis and the images were scanned and transferred to personal computer. Measurements were obtained by AutoCad software and statistics by Graph Pad Instat software. Our data were compared using Kolmogorov-Smirnov and "t-test". The following parameters were evaluated: femoral head diameter (FHD), femoral neck length (FNL), femoral neck width (FNW), femoral axis length (FAL), off-set (OS) and cervical-diaphyseal angle (CDA). The findings were as follows (mean ± SD), right and left sides respectively: FHD, 31.1 ± 2.7 mm and 30.8 ± 3.0 mm; FNL, 30.1 ± 4.3 mm and 30.5 ± 4.1mm; FNW, 30.96 ± 2.94 mm; FAL, 98.2 ± 5.9 mm and 97.4 ± 7.13 mm; OS, 42.6 ± 6.1 mm and 42.0 ± 5.6 mm; CDA, 132.0 ± 7.2 e 131.8 ± 5.2. Median cervical-diaphyseal angle, obtained in this study presented some variation, which was not statistically significant. Linear data are constant, according to other studies, except the off-set, which has varied. Junto al envejecimiento de la población de Brasil, producto de la mayor expectativa de vida, ha aumentado la incidencia en las fractura de la parte proximal del fémur. Para el tratamiento de estas fracturas se utilizan implantes, los que estan basados en mediciones realizadas en caucásicos, incluido los 135 grados del ángulo cervico-diafisario. Conocer la morfometría femoral permite evaluar adecuabilidad de los implantes. Se realizó este estudio con 110 fémures humanos (49 derechos y 61 izquierdos) de individuos brasile os. Se excluyeron del estudio: los huesos sometidos a osteosíntesis, a prótesis o en los que se detectaron anormalidades o malformaciones que pudieran afectar su estructura y forma. Los huesos fueron sometidos a análisis radiográfico y las imágenes digitalizadas y transferidas a un computador personal. Las mediciones se obtuvieron mediante el software AutoCAD y las estadísticas con el software Instat. Nuestros datos se compararon con la prueba de Kolmogorov-Smirnov y "t-test". Los siguientes parámetros fuer

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133