In this study, a novel amperometric glucose biosensor with immobilization of glucose oxidase on electrochemically polymerized polyaniline-polyvinylsulphonate (Pani-Pvs) films has been accomplished via the entrapment technique. Electropolymerization of aniline on the Pt surface of the Pt electrode was carried out at constant potential (0.75 V, vs. Ag/AgCl) using an electrochemical cell containing aniline and polyvinylsulphonate. Firstly, the optimum working conditions for preparing polyaniline-polyvinylsulfonate films were investigated. Determination of glucose was carried out by the oxidation of enzymatically produced H2O2 at 0.4 V vs. Ag/AgCl. The effects of pH and temperature were investigated and the optimum pH value was found to be 7.5. The storage stability and operational stability of the enzyme electrode were also studied. The results show that 75% of the response current was retained after 16 activity assays. The prepared glucose biosensor retained 80.6% of initial activity after 40 days when stored in 0.1 M phosphate buffer solution at 4 °C.
References
[1]
Bidan, G. Electroconducting conjugated polymers: new sensitive matrices to build up chemical or electrochemical sensors. Sens. Actuat. B Chem 1992, 6, 45–56, doi:10.1016/0925-4005(92)80029-W.
Barlett, PN; Cooper, JM. A review of the immobilization of enzymes in electropolymerized films. J Electroanal Chem 1993, 362, 1–12, doi:10.1016/0022-0728(93)80001-X.
Cosiner, S. Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. Biosens. Bioelectron 1999, 14, 443–456, doi:10.1016/S0956-5663(99)00024-X. 10451912
[6]
Yoo, E-H; Lee, S-Y. Glucose biosensors: An overview of use in clinical practice. Sensors 2010, 10, 4558–4576, doi:10.3390/s100504558. 22399892
[7]
Norouzi, P; Faridbod, F; Larijani, B; Ganjali, MR. Glucose biosensor based on MWCNTs-Gold nanoparticles in a Nafion film on the glassy carbon electrode using flow injection FFT continuous cyclic voltammetry. Int. J. Electrochem. Sci 2010, 5, 1213–1224.
[8]
Gros, P; Durliat, H; Comtat, M. Use of polypyrrole film containing Fe(CN)63? as pseudo-reference electrode: Application for amperometric biosensors. Electrochim. Acta 2000, 46, 643–650.
[9]
Zhang, Y; Wen, G; Zhou, Y; Shuang, S; Dong, C; Choi, MMF. Development and analytical application of an uric acid biosensor using an uricase-immobilized eggshell membrane. Biosens. Bioelectron 2007, 22, 1791–1797, doi:10.1016/j.bios.2006.08.038. 17023154
[10]
Shan, D; Wang, S; He, Y; Xue, H. Amperometric glucose biosensor based on in situ electropolymerized polyaniline/poly (acrylonitrile-co-acrylic acid) composite film. Mater. Sci. Eng. C 2008, 28, 213–217, doi:10.1016/j.msec.2006.12.003.
[11]
Gaikwad, PD; Shirale, DJ; Savale, PA; Datta, K; Ghosh, P; Shirsat, MD. Development of PANI-PVS-GOD electrode by potentiometric method for determination of glucose. Int. J. Electrochem. Sci 2007, 2, 488–497.
[12]
Xue, H; Shen, Z; Li, C. Improved selectivity and stability of glucose biosensor based on in situ electropolymerized polyaniline-polyacrylonitrile composite film. Biosens. Bioelectron 2005, 20, 2330–2334, doi:10.1016/j.bios.2004.07.018. 15797335
[13]
Shi, Q; Wang, P; Jiang, Y; Kan, J. Glucose biosensor based on polyaniline synthesized in ionic liquid. Biocatal. Biotransform 2009, 27, 54–59, doi:10.1080/10242420802400025.
[14]
Chen, C; Jiang, Y; Kan, J. A noninterference polypyrrole glucose biosensor. Biosens. Bioelectron 2006, 22, 639–643, doi:10.1016/j.bios.2006.01.023. 16540308
[15]
Xue, H; Shen, Z; Li, Y. Polyaniline-polyisoprene composite film based glucose biosensor with high permselectivity. Synth. Met 2001, 124, 345–349, doi:10.1016/S0379-6779(01)00381-2.
[16]
Zhou, H; Chen, H; Luo, S; Chen, J; Wei, W. Glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline. Biosens. Bioelectron 2005, 20, 1305–1311, doi:10.1016/j.bios.2004.04.024. 15590283