A new method for estimation of angles of leg segments and joints, which uses accelerometer arrays attached to body segments, is described. An array consists of two accelerometers mounted on a rigid rod. The absolute angle of each body segment was determined by band pass filtering of the differences between signals from parallel axes from two accelerometers mounted on the same rod. Joint angles were evaluated by subtracting absolute angles of the neighboring segments. This method eliminates the need for double integration as well as the drift typical for double integration. The efficiency of the algorithm is illustrated by experimental results involving healthy subjects who walked on a treadmill at various speeds, ranging between 0.15 m/s and 2.0 m/s. The validation was performed by comparing the estimated joint angles with the joint angles measured with flexible goniometers. The discrepancies were assessed by the differences between the two sets of data (obtained to be below 6 degrees) and by the Pearson correlation coefficient (greater than 0.97 for the knee angle and greater than 0.85 for the ankle angle).
References
[1]
Furnee, H. Real-time motion capture systems. In Three-Dimensional Analysis of Human Locomotion; Allard, P., Cappozzo, A., Lundberg, A., Vaughan, C.L., Eds.; Wiley: New York, NY, USA, 1997; pp. 85–108.
[2]
Kiss, R.M.; Kocsis, L.; Knoll, Z. Joint kinematics and spatial-temporal parameters of gait measured by an ultrasound-based system. Med. Eng. Phys 2004, 26, 611–620.
[3]
Kobayashi, K.; Gransberg, L.; Knutsson, E.; Nolén, P. A new system for three-dimensional gait recording using electromagnetic tracking. Gait Posture 1997, 6, 63–75.
[4]
Bonomi, A.; Salati, S. Assessment of human ambulatory speed by measuring near-body air flow. Sensors 2010, 10, 8705–8718.
[5]
Pallejà, T.; Teixidó, M.; Tresanchez, M.; Palacín, J. Measuring gait using a ground laser range sensor. Sensors 2009, 9, 9133–9146.
[6]
Yun, J. User identification using gait patterns on UbiFloorII. Sensors 2011, 11, 2611–2639.
[7]
Liu, T.; Inoue, Y.; Shibata, K. A wearable ground reaction force sensor system and its application to the measurement of extrinsic gait variability. Sensors 2010, 10, 10240–10255.
[8]
Allet, L.; Knols, R.; Shirato, K.; Bruin, E. Wearable systems for monitoring mobility-related activities in chronic disease: A systematic review. Sensors 2010, 10, 9026–9052.
[9]
Zheng, H.; Black, N.D.; Harris, N.D. Position-sensing technologies for movement analysis in stroke rehabilitation. Med. Biol. Eng. Comp 2005, 43, 413–420.
[10]
Legnani, G.; Zappa, B.; Casolo, F.; Adamini, R.; Magnani, P.L. A model of an electro-goniometer and its calibration for biomechanical applications. Med. Eng. Phys 2000, 22, 711–722.
[11]
Shiratsu, A.; Coury, H.J.C.G. Reliability and accuracy of different sensors of a flexible electrogoniometers. Clin. Biomech 2003, 18, 682–684.
[12]
Mayagoitia, R.E.; Nene, A.V.; Veltink, P.H. Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems. J. Biomech 2002, 35, 537–542.
[13]
Aminian, K.; Najafi, B.; Bnla, C.; Leyvraz, P.F.; Robert, P. Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes. J. Biomech 2002, 35, 689–699.
[14]
Dejnabadi, H.; Jolles, B.M.; Aminian, K. A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes. IEEE Trans. Biomed. Eng 2005, 52, 1478–1484.
[15]
Luczak, S.; Oleksiuk, W.; Bodnicki, M. Sensing tilt with MEMS accelerometers. IEEE Sensors J 2006, 6, 1669–1675.
[16]
Yang, C.C.; Hsu, Y.L. A review of accelerometry-based wearable motion detectors for physical activity monitoring. Sensors 2010, 10, 7772–7788.
[17]
Mizuike, C.; Ohgi, S.; Morita, S. Analysis of stroke patient walking dynamics using a tri-axial accelerometer. Gait Posture 2009, 30, 60–64.
[18]
Eng, J.J.; Winter, D.A. Kinetic analysis of the lower limbs during walking: What information can be gained from a three-dimensional model? J. Biomech 1995, 28, 753–758.
[19]
Takeda, R.; Tadano, S.; Todoh, M.; Morikawa, M.; Nakayasu, M.; Yoshinari, S. Gait analysis using gravitational acceleration measured by wearable sensors. J. Biomech 2009, 42, 223–233.
[20]
Takeda, R.; Tadano, S.; Natorigawa, A.; Todoh, M.; Yoshinari, S. Gait posture estimation using wearable acceleration and gyro sensors. J. Biomech 2009, 42, 2486–2494.
[21]
Yang, C.; Hsu, Y.; Shih, K.; Lu, J. Real-time gait cycle parameter recognition using a wearable accelerometry system. Sensors 2011, 11, 7314–7326.
[22]
Favre, J.; Jolles, B.M.; Aissaoui, R.; Aminian, K. Ambulatory measurement of 3D knee joint angle. J. Biomech 2008, 41, 1029–1035.
[23]
O’Donovan, K.J.; Kamnik, R.; O’Keeffe, D.T.; Lyons, G.M. An inertial and magnetic sensor based technique for joint angle measurement. J. Biomech 2007, 40, 2604–2611.
[24]
Williamson, R.; Andrews, B.J. Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes. Med. Biol. Eng. Comp 2001, 39, 294–302.
[25]
Ferrari, A.; Cutti, A.G.; Garofalo, P.; Raggi, M.; Heijboer, M.; Cappello, A.; Davalli, A. First in vivo assessment of “Outwalk”: A novel protocol for clinical gait analysis based on inertial and magnetic sensors. Med. Biol. Eng. Comp 2010, 48, 1–15.
[26]
Morris, J.R.W. Accelerometry—A technique for the measurement of human body movements. J. Biomech 1973, 6, 729–736.
[27]
Tong, K.; Granat, M.H. A practical gait analysis system using gyroscopes. Med. Eng. Phys 1999, 21, 87–94.
[28]
Dejnabadi, H.; Jolles, B.M.; Casanova, E.; Fua, P.; Aminian, K. Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors. IEEE Trans. Biomed. Eng 2006, 53, 1385–1393.
[29]
Luinge, H.J.; Veltink, P.H. Inclination measurement of human movement using a 3-D accelerometer with autocalibration. IEEE Trans. Neur. Syst. Rehabil. Eng 2004, 12, 112–121.
[30]
Luinge, H.J.; Veltink, P.H. Measuring orientation of human body segments using miniature gyroscopes and accelerometers. Med. Biol. Eng. Comp 2005, 43, 273–282.