%0 Journal Article %T Evaluation study of an ion selective field effect transistor electrode for measuring quality parameters of fuel ethanol %A Gonzaga %A Fabiano B. %A Sobral %A Sidney P. %A Ribeiro %A Carla M. %A Gon£¿alves %A Mary A. %J Journal of the Brazilian Chemical Society %D 2013 %I Sociedade Brasileira de Qu¨ªmica, SBQ %R 10.1590/S0103-50532013000100008 %X an ion selective field effect transistor (isfet) electrode was evaluated for measuring ph and acid number (an) of fuel ethanol and compared to two glass electrodes with different reference filling solutions: kcl aqueous solution (glass-kcl electrode) and licl ethanolic solution (glass-licl electrode). ph was determined at different measurement times and an was determined using automatic potentiometric titration. for ph, the glass-kcl electrode showed the best precision and stability, with an average repeatability about four times better when compared to the isfet electrode for the measurement time of 30 s (as indicated in the astm d6423 standard). for an, the glass-kcl and glass-licl electrodes showed similar repeatabilities, which were about three times better than that of the isfet electrode. in addition, the results from a recovery study demonstrated better accuracy of the glass-licl electrode, with a recovery value of 100.1%. %K isfet electrode %K glass electrode %K fuel ethanol %K acid number %K ph. %U http://www.scielo.br/scielo.php?script=sci_abstract&pid=S0103-50532013000100008&lng=en&nrm=iso&tlng=en