%0 Journal Article %T 微波消解–原子荧光法测定夏蝉总汞检测
Detection of Total Mercury by Microwave Digestion-Atomic Fluorescence Method %A 李奕霄 %A 曹源源 %A 罗怡 %J World Journal of Forestry %P 56-60 %@ 2169-2440 %D 2025 %I Hans Publishing %R 10.12677/wjf.2025.141007 %X 本研究采用微波消解–原子荧光法测定夏蝉体内汞的含量。5 g夏蝉样品经过微波消解后,载流为5%的硝酸溶液,还原剂为0.5%氢氧化钾+0.01%硼氢化钠,利用原子荧光光度计检测。结果显示,检出限为0.045 μg·L−1,R² ≥ 0.9998,回收率为84.2%~116.40%,RSD ≤ 2.15%,所得出的汞标准曲线呈现良好的线性关系。该方法准确、可靠,适用于夏蝉体内汞含量检测。
This study utilized microwave digestion-atomic fluorescence spectrometry to determine the mercury content in Cicada (summer cicada) samples. After microwave digestion of 5g cicada samples, a 5% nitric acid solution was used as the carrier, and a reducing agent mixture of 0.5% potassium hydroxide and 0.01% sodium borohydride was applied. Detection was performed using an atomic fluorescence spectrophotometer. The results showed a detection limit of 0.045 μg·L1, with R² ≥ 0.9998. The recovery rate ranged from 84.2% to 116.40%, and the relative standard deviation (RSD) was less than or equal to 2.15%. The mercury standard curve exhibited good linearity. This method is accurate and reliable, making it suitable for detecting mercury content in cicadas. %K 微波消解, %K 原子荧光法, %K 夏蝉, %K 汞, %K 植食性昆虫, %K 土壤重金属
Microwave Digestion %K Atomic Fluorescence Method %K Summer Hopper %K Mercury %K Herbivorous Insect %K Soil Heavy Mental %U http://www.hanspub.org/journal/PaperInformation.aspx?PaperID=104296