%0 Journal Article
%T 微电解-Fenton-生化组合工艺处理实验室废气吸收尾液
Micro-Electrolysis-Fenton-Biochemical Combination Process for Laboratory Waste Gas Absorption Tailings
%A 苏洲
%A 张键
%A 何茂林
%A 居则易
%J Advances in Environmental Protection
%P 987-993
%@ 2164-5493
%D 2021
%I Hans Publishing
%R 10.12677/AEP.2021.115118
%X
针对某高校实验室废气净化设备排放的吸收尾液废水有机成分复杂、B/C低和水质变化大等特点,首次采用微电解-Fenton-生化组合工艺进行实验室废气吸收尾液废水处理。处理设施运行结果表明,该组合工艺运行稳定,出水SS、CODcr、BOD5、NH3-N、阴离子表面活性剂和挥发酚分别低于200 mg/L、210 mg/L、74 mg/L、19 mg/L、8.5 mg/L和0.5 mg/L。出水各项指标均达到了《污水排入城镇下水道水质标准》(GB-T31962-2015)表I中A级排放标准。工程总投资136.4万元,单位运行成本6.24元/m3。
Aiming at the characteristics of complex organic composition, low B/C and large water quality changes in the absorbing tail liquid wastewater discharged from laboratory exhaust gas purification equipment in a certain university, the micro-electrolysis-Fenton-biochemical combined process was used to treat the laboratory exhaust gas absorption tail liquid wastewater. The results show that the combined process is stable and the effluent SS, CODcr, BOD5, NH3-N, anionic surfactant, and volatile phenol are lower than 200 mg/L, 210 mg/L, 74 mg/L, 19 mg/L, 8.5 mg/L, 0.5 mg/L, re-spectively. Various indicators of the effluent have achieved the Class A discharge standard in Table I of the “Water Quality Standard for Sewage Discharged into Urban Sewers” (GB-T31962-2015). The total project investment is 1.364 million yuan, and the operating cost is 6.24 yuan/m3.
%K 吸收尾液,微电解,Fenton,生化组合工艺,实验室废气,废水处理
Absorbing Tail Liquid
%K Micro-Electrolysis
%K Fenton
%K Biochemical Combined Process
%K Laboratory Waste Gas
%K Wastewater Treatment
%U http://www.hanspub.org/journal/PaperInformation.aspx?PaperID=45847