%0 Journal Article %T Perbandingan hasil pengukuran pada citra Cone Beam Computed Tomography (CBCT) dengan objek sesungguhnya %A Munakhir Mudjosemedi %A Ratihana Nurul Indias %A Rini Widyaningrum %A Rurie Ratna Shantiningsih %J - %D 2017 %R https://doi.org/10.22146/majkedgiind.15240 https://doi.org/10.22146/majkedgiind.15240 %X The distance comparison of Cone Beam Computed Tomography (CBCT) image with the real object. Dentist use radiographs to establish diagnosis, treatment plan, prognosis, as well as to evaluate patient¡¯s treatment. Accurate anatomical dimension is a pivotal point in radiography, especially in the field of oral surgery and dental implant planning. The information about distortion in radiograph is very important to prevent any misdiagnosis and incorrect treatment plan. The purpose of this study was to compare the metal marker distance in CBCT image with the real measurement in dried mandibles. Samples in this study were 40 CBCT images of human dried mandibles, which were produced by using Volux 3D dental CT (Genoray, Korea, 60 kVp, 60 mAs, 10s). Horizontal, vertical, and oblique measurements on CBCT image were done by using Volux 3D dental CT software (GDP-1 software Triana). The measurement on CBCT image was compared with the real measurement by using Wilcoxon signed rank test. Image distortion was calculated by subtracting the metal marker distance obtained from CBCT images by the real distance obtained by a direct measurement on dried mandible. The distortion was expressed as a percentage. There were some significant differences (p<0.05) between metal marker distance on CBCT image with a direct measurement in dried mandibles, except oblique measurements on anterior mandibular body that was done without involving mandibular base. The maximal distortion on panoramic view of CBCT image in this study was 8%, and the distortion was different in each part of the mandible. ABSTRAK Pemeriksaan radiografi diperlukan oleh dokter gigi untuk menetapkan diagnosis, rencana perawatan, prognosis, dan evaluasi hasil perawatan. Radiograf yang memiliki ketepatan dimensi anatomi diperlukan pada tindakan bedah dan pemasangan implan. Informasi mengenai distorsi hasil pengukuran pada radiograf diperlukan untuk mencegah kesalahan penetapan diagnosis dan rencana perawatan. Penelitian ini bertujuan untuk mengetahui perbandingan jarak metal marker pada pengukuran horizontal, vertikal, dan oblique citra Cone Beam Computed Tomography (CBCT) dengan objek sesungguhnya pada preparat mandibula kering. Sampel penelitian berupa 40 citra CBCT preparat mandibula kering yang dihasilkan oleh mesin Volux 3D dental CT (Genoray, Korea) dengan menggunakan tegangan 60 kVp, kuat arus 60 mAs, dan waktu paparan 10 detik. Pengukuran pada citra CBCT dilakukan dengan mengukur jarak terjauh antara kedua metalmarker secara horizontal, vertikal, dan oblique menggunakan software Volux 3D dental CT (GDP-1 %K Cone Beam Computed Tomography (CBCT) %K mandible %K metal marker %K measurement %U https://jurnal.ugm.ac.id/mkgi/article/view/15240