%0 Journal Article %T Reversed Phase High Performance Liquid Chromatography Method for Determination of Ambroxal Hydrochloride from Active Pharmaceutical dosage form %J - %D 2015 %X A simple, rapid and accurate high performance liquid chromatography method is described for determination of ambroxal hydrochloride from active pharmaceutical ingredients. The separation of drug was achieved on BDS hypersil C18 (150 x 4.6 mm i.d.) with 5 ¦Ì particle size column showed most favorable chromatographic pattern over the other columns. The mobile phase consisted of a mixture of buffer and acetonitrile (70:30 % v/v). The buffer was mixtures of 0.1 % tri-ethyl amine solution adjusted the pH 4.0 with acetic acid. The detection was carried out at wavelength 250 nm. The mixture of buffer of pH 4 and acetonitrile (50:50% v/v) was used as a diluent. The method was validated for system suitability, linearity, accuracy, precision, robustness, stability of sample solution. The method has been successfully used to analyze ambroxal hydrochloride from active pharmaceutical ingredients %K Rajan V.Rele %K Ambroxal hydrochloride %K Acetonitrile %K tri-ethyl amine %K acetic acid. %U https://www.imedpub.com/abstract/reversed-phase-high-performance-liquid-chromatography-method-for-determination-of-ambroxal-hydrochloride-from-active-pharmaceutical-dosage-form-11649.html