%0 Journal Article %T Recycling of the Pulmonary Autograft During Reverse Ross Operation: From Pulmonary Valve to Neoaortic Valve and Back %A Dominique Bettex %A Martin Schmiady %A Martin Schweiger %A Michael H¨ıbler %J World Journal for Pediatric and Congenital Heart Surgery %@ 2150-136X %D 2019 %R 10.1177/2150135118798584 %X The Ross operation is the operation of choice for children and young adults who require aortic valve replacement. Although the allograft does not require anticoagulation and has a superior hemodynamic profile compared to other valve substitutes, concerns regarding allograft and autograft longevity have risen in the last decade. We present a case illustrating an alternative operative technique for patients with failed Ross procedure in which the autograft is recycled in order to avoid a two-allograft replacement %K Ross procedure %K congenital %K valves %K autograft %K degeneration %K reoperation %U https://journals.sagepub.com/doi/full/10.1177/2150135118798584