%0 Journal Article %T Optoelectronic measurement of wrist movements in various casts and orthoses used in scaphoid fractures %A Andrew Waton %A Gemma M. Whatling %A Sarah Forrest %J Journal of Hand Surgery (European Volume) %@ 2043-6289 %D 2019 %R 10.1177/1753193419842519 %X We developed an optoelectronic motion analysis protocol to measure anatomical and functional ranges of wrist motion in Colles¡¯-type and scaphoid-type splints and casts. The protocol was used to study the restriction of wrist motion in casts and splints in ten healthy volunteers. Scaphoid-type casts were no more restrictive to wrist motion than Colles¡¯-type casts, but casts were significantly more restrictive than removable splints. Removable splints were more restrictive than no immobilization. Results suggest there is no benefit in using scaphoid-type casts rather than Colles¡¯-type casts to reduce wrist motion %K Scaphoid fracture %K immobilization %K scaphoid cast %K Colles¡¯ cast %K optoelectronic %U https://journals.sagepub.com/doi/full/10.1177/1753193419842519