%0 Journal Article %T 三塔悬索桥主缆与中塔鞍座抗滑简化计算方法 %A 王秀兰 %A 徐岳 %A 柴生波 %J 哈尔滨工业大学学报 %D 2016 %R 10.11918/j.issn.0367-6234.2016.09.013 %X 为研究三塔悬索桥主缆与鞍座的抗滑特性,给出了三塔悬索桥主缆抗滑安全系数的简化计算方法. 考虑活载作用下塔、缆变形以及加载跨与非加载跨主缆内力的平衡关系,推导鞍座处主缆抗滑安全系数的解析计算公式;建立有限元模型对公式进行验证;研究垂跨比、塔缆刚度比、恒活载比、跨径等主要设计参数对主缆抗滑安全系数的影响. 研究表明:该公式可用于悬索桥初步设计阶段主缆抗滑安全系数的估算,能够为设计参数的合理取值提供理论依据. 主缆抗滑安全系数随着塔缆刚度比增大而减小,当塔缆刚度比小于3时,增大塔缆刚度比,主缆抗滑安全系数迅速减小,当塔缆刚度比大于3时,塔缆刚度比对主缆抗滑安全系数影响较小;垂跨比对主缆抗滑安全系数的影响取决于桥塔刚度;主缆抗滑安全系数随着恒活载比值及跨径增大而增大.</br>To study anti-slip characteristics of main cable and saddle of three-tower suspension bridges,a simplified calculation method for calculating anti-slip factor was proposed. Analytical formulas for calculating anti-slip factor were deduced and finite element models were established to verify formulas. The effects of some important design parameters on the anti-slip factor were studied. Analysis shows that the analytical method has a high accuracy,which can be used in preliminary design of three-tower suspension bridges. With the ratio of tower and cable stiffness increasing,the anti-slip factor decreases; when the ratio of tower and cable stiffness is less than 3,changing the ratio of tower and cable stiffness has a great influence on the anti-slip factor. When the ratio of tower and cable stiffness is more than 3,the anti-slip factor is not sensitive to the ratio of tower and cable stiffness. Effect of sag-to-span ratio to the anti-slip factor depends on the tower stiffness. With the increment of span length and the ratio of dead load and live load,the anti-slip factor increases. %K 悬索桥 %K 三塔 %K 解析法 %K 抗滑 %K 主缆< %K /br> %K suspension %K bridge %K three-tower %K analytic %K method %K anti-slip %K main %K cable %U http://hit.alljournals.cn/hitxb_cn/ch/reader/view_abstract.aspx?file_no=20160914&flag=1