%0 Journal Article %T A Radiotherapy Treatment Margin Formula When Systematic Positioning Errors are Relatively Small Compared to Random Positioning Errors: A First-Order Approximation %A Kiyoshi Yoda %J International Journal of Medical Physics,Clinical Engineering and Radiation Oncology %P 193-196 %@ 2168-5444 %D 2017 %I Scientific Research Publishing %R 10.4236/ijmpcero.2017.62017 %X A radiotherapy treatment margin formula has been analytically derived when a standard deviation (SD) of systematic positioning errors &#425; is relatively small compared to an SD of random positioning errors &sigma;. The margin formula for 0 ¡Ü &#425; ¡Ü &sigma; was calculated by linearly interpolating two boundaries at &#425; = 0 and &#425; = &sigma;, assuming that the van Herk margin approximation of <i>k<sub>1</sub></i>&#425; + <i>k<sub>2</sub></i>&sigma; is valid at &#425; = &sigma;. It was shown that a margin formula for 0 ¡Ü &#425; ¡Ü &sigma; may be approximated by <i>k<sub>1</sub></i>&sigma; + <i>k<sub>2</sub></i>&#425;, leading to a more general form of <i>k<sub>1</sub></i> max(&#425;,&sigma;) + <i>k<sub>2</sub></i> min(&#425;,&sigma;) which is a piecewise linear approximation for any values of &#425; and &sigma;. %K Treatment Margin %K Systematic Positioning Errors %K Random Positioning Errors %U http://www.scirp.org/journal/PaperInformation.aspx?PaperID=76361