%0 Journal Article %T The shape and size of femoral components in revision total hip arthroplasty among Chinese patients. %A Chiu KY %A Ng TP %A Tang WM %A Cheng HC %J Journal of Orthopaedic Surgery %D 2003 %I Hong Kong Academy of Medicine Press %X OBJECTIVE: 39 sets of preoperative hip X-rays were studied to find out whether Chinese patients need revision femoral components with a different shape and size from western patients. METHODS: From July 1998 to June 2001, the pre-revision X-rays of 39 revision total hip replacements among 38 Chinese patients (21 men and 17 women) were studied. The component size that produced the best distal canal-filling in the anteroposterior X-ray was determined by using templates of 200-mm femoral components used commonly for Caucasian patients. RESULTS: The diameter of the component needed was 13.5 mm or less in 54% of cases, compared with only 17% for Caucasian patients as reported in the literature (p<0.01). When lateral templates of the corresponding size were put over the lateral X-rays, the anterior cortex of the 200-mm straight stem was shown to have thinned by 2.0 mm or more in 36% of hips; for 200-mm bowed stem, there was thinning of the anterior cortex by 2.0 mm or more in only 5% of hips (p<0.01). CONCLUSION: Chinese patients are likely to need smaller femoral components than Caucasian patients, and may benefit from bowed-stem components in femoral revision. %U http://www.josonline.org/abstracts/v11n1/53.html