%0 Journal Article %T ESR Dosimetric Study on Gamma Induced Radicals in DL-Ornithine Hydrochloride %A Sayeda Eid %J Open Journal of Polymer Chemistry %P 23-28 %@ 2165-6711 %D 2013 %I Scientific Research Publishing %R 10.4236/ojpchem.2013.31005 %X
DL-ornithine hydrochloride rods (3 ¡Á10 mm) were studied to be a radiation sensitive material for EPR dosimetry. The rods have specified EPR signal developed under irradiation and its intensity increases with the increase in absorbed dose. The intensity also affected by the concentration of DL-ornithine in the rods. The prepared rods can be used in the dose range from 0.5 - 50 kGy. The obtained number of free radicals per 100 eV (G value) was found to be 0.3551 ¡À 0.0333. The hyperfine (hf) coupling constant is 2.325 mT at g-factor 2.033. The rods have the advantage of negligible humidity effects during irradiation. The pre and post- irradiation stability was found to be satisfactory.
%K Ornithine %K EPR %K Dosimetry %U http://www.scirp.org/journal/PaperInformation.aspx?PaperID=28479