%0 Journal Article %T Desarrollo y evaluaci車n de un protocolo serol車gico de fluorescencia polarizada en el estudio de anticuerpos contra Brucella spp en humanos Development and evaluation of a serological protocol of fluorescence polarization for the preliminary study of Brucella spp antibodies in humans %A Alfredo S芍nchez-Villalobos %A Margelys Urdaneta-Fern芍ndez %A El赤 Rubio-Fuenmayor %A Gladys Molero-Saras %J Investigaci車n Cl赤nica %D 2011 %I Scientific Electronic Library Online %X A objeto de mostrar el desarrollo y alcance de un m谷todo de an芍lisis serol車gico basado en la t谷cnica de fluorescencia polarizada (FPA) a partir de una gota de sangre obtenida mediante punci車n capilar, se realiz車 la determinaci車n de anticuerpos antibrucelosis de un conjunto de 321 personas de alto riesgo laboral. Los resultados se compararon con la data proveniente del an芍lisis de sueros sangu赤neos mediante FPA e inmunoan芍lisis enzim芍tico competitivo (ELISA-c). El n迆mero de concordantes fue 318 (99,06%), los 3 discordantes (0,93%) resultaron negativos con fluorescencia polarizada en suero (FPAs) y ELISA-c, pero positivos con FPA capilar (FPAc). Los resultados comparativos de FPAc fueron: sensibilidad: 100%; especificidad: 99,05%; valor predictivo positivo: 66,67%; valor predictivo negativo: 100,0%; proporci車n de falsos positivos: 0,95%; proporci車n de falsos negativos: 0%; exactitud: 98,0%; raz車n de probabilidades: 203,00. La J de Youden para ambos m谷todos de FPA fue de 0,667. La determinaci車n se consider車 confiable y la concordancia de ambos procedimientos de FPA y ELISA-c result車 sin diferencias estad赤sticas (P>0,05%), lo que permite recomendar ampliamente la implementaci車n del estudio de la brucelosis humana con sangre proveniente de punci車n capilar como m谷todo preliminar In order to show the development and scope of a serological analysis method based on fluorescence polarization assay (FPA) from a drop of blood obtained by the capillary technique, a Brucella antibody assay was performed on a group of 321 high-risk workers. The results were compared with data from the analysis of blood serum by FPA and a competitive enzyme immunoassay (ELISA-c). The number of concordance was 318 (99.06%), and discordant 3 (0.93%), which were negative in serum by fluorescence polarization (FPAs) and ELISA-c, but positive with capillary FPA (FPAc). The comparative results FPAc were: sensitivity 100%; specificity: 99.05%; positive predictive value 66.67%; negative predictive value 100.0%; false positive rate: 0.95%; false negative rate: 0%; accuracy: 98.0%; odds ratio: 203.00. The youden J for both FPA methods was 0.667. The identification was considered reliable and the correlation of both procedures, FPA and ELISA-c, was no statistically different (P> 0.05%), which allows to highly recommend the study implementation of human brucellosis with capillary blood as a preliminary method %K Brucelosis humana %K fluorescencia polarizada %K punci車n capilar %K Human brucellosis %K fluorescence polarization %K blood capillary %U http://wwww.scielo.org.ve/scielo.php?script=sci_arttext&pid=S0535-51332011000100006