%0 Journal Article %T An Unusual Cause of Recurrent Laryngeal Nerve Monitoring Failure during Parathyroidectomy %A KATARINA BOJANI£¿ %A AMANDA R. MORASKA %A JURAJ SPRUNG %A GEOFFREY B. THOMPSON %J Signa Vitae %D 2011 %I Pharmamed Mado %X Intraoperative monitoring of the recurrent laryngeal nerve (RLN) during surgical dissection allows for real time identification and assessment of nerve function integrity. Since neuromuscular blockade interferes with electromyography, long-acting muscle relaxants cannot be used during anesthesia. We report a patient in whom monitoring of the RLN was unsuccessful because of prolonged muscle paralysis following the administration of succinylcholine, presumably due to a pseudocholinesterase deficiency. %K laryngeal nerve monitoring %K muscle paralysis %K pseudocholinesterase deficiency %U http://www.signavitae.com/articles/case-reports/185-an-unusual-cause-of-recurrent-laryngeal-nerve-monitoring-failure-during-parathyroidectomy