%0 Journal Article %T Determinaci車n del punto de muestreo 車ptimo, para la evaluaci車n de las concentraciones de Part赤culas Suspendidas Totales (PST) en una zona semiurbana de Colombia Determination of the optimum point of sampling, for the evaluation of the concentrations of Total Suspended Particles (TSP) in a semiurban Colombian area %A Roberto Rojano %A Jhonny P谷rez %A Andr谷s Galindo %A Yoma Mendoza %J Revista T谷cnica de la Facultad de Ingenier赤a Universidad del Zulia %D 2008 %I Scientific Electronic Library Online %X Establecer una red de monitoreo genera costos tanto en recurso econ車mico como humano. En la presente investigaci車n se aplic車 un procedimiento l車gico con la finalidad de facilitar la selecci車n de un 迆nico sitio para el monitoreo atmosf谷rico de part赤culas suspendidas totales, PST, cuyo volumen de muestra sea representativo de las caracter赤sticas del aire presente en la ciudad de Sincelejo, Colombia. Para la localizaci車n del punto adecuado de muestreo, se realiz車 un inventario de las fuentes de emisi車n de part赤culas, obteni谷ndose como resultado un total de 34 fuentes con diversos grados de contribuci車n. Partiendo de dicha informaci車n y de factores de emisi車n desarrollados por la EPA se determinaron las diferentes tasas de emisi車n que usadas conjuntamente con las condiciones meteorol車gicas prevalecientes y el nomograma de Turner [1], permitieron establecer las concentraciones m芍ximas de exposici車n al poluente y a que distancia ocurre de la correspondiente fuente. La localizaci車n individual 車ptima para la evaluaci車n de los niveles de PST recay車 en las instalaciones de la C芍mara de Comercio de la ciudad. El muestreo piloto de un mes con frecuencia interdiaria arroj車 concentraciones de part赤culas entre 26,52 y 76,01 米g/m3, con un promedio geom谷trico de 45,07 米g/m3, valor muy por debajo (55%) de lo establecido por la norma colombiana, decreto 02 de 1982(<100 米g/m3). To establish a monitoring network generates costs either in economic resource or in the human one. In this research a logical procedure was applied to facilitate the selection of the single site for the atmospheric monitoring of total suspended particles -TSP- whose sample volume is representative of the characteristics of the air present in the city of Sincelejo, Colombia. For the localization of the appropriate point of sampling, an inventory of the sources of emission of particles was carried out, obtaining a total of 34 sources as a result with diverse contribution grades. Based on this information and on the emission factors developed by the EPA, the different emission rates were determined, which were used together with the prevalent meteorological conditions and the nomograme of Turner [1]. They allowed to establish the maximum concentrations of exposition to the poluent and the distances from the corresponding source. The best individual localization for the evaluation of the levels of PST was the Chamber of Commerce Building of the city. The sampling pilot of one month, every other day, gave concentrations of particles between 26,52 and 76,01 米g/m3, with a geometric average of 45,07 米g/m3, %K Part赤culas suspendidas totales %K punto 車ptimo de muestreo %K variables meteorol車gicas %K concentraci車n m芍xima %K fuentes de emisi車n %K Total suspended particles %K optimum point of sampling %K meteorological variables %K maximum concentration %K emission sources %U http://wwww.scielo.org.ve/scielo.php?script=sci_arttext&pid=S0254-07702008000300001