%0 Journal Article %T Preliminary results of ion trajectory tracking in the acceleration region of the VINCY cyclotron %A Ili£¿ An£¿elija £¿. %A Risti£¿-£¿urovi£¿ Jasna L. %A £¿irkovi£¿ Sa£¿a T. %J Nuclear Technology and Radiation Protection %D 2006 %I VIN?A Institute of Nuclear Sciences %R 10.2298/ntrp0601029i %X In an accelerating region of a cyclotron, an ion makes a large number of turns; thus, its n the Runge-Kutta method of the fourth order with the adaptive time step has been developed. The accuracy requirement is simultaneously set on position and momentum calculation. Magnetic fields used as inputs, have been evaluated in terms of the radial fluctuations of the orbital frequency, i.e. their isochronisms. Ion trajectory tracking has been performed for the following four test beams: H-, H+3, 4He+, He+, and 40Ar6+. %K cyclotron %K ion beam %K trajectory tracking %K adaptive time step %K magnetic fields %K isochronism %U http://www.doiserbia.nb.rs/img/doi/1451-3994/2006/1451-39940601029I.pdf